Abdel-Razzak Mohammad Al-Hinnawi

Prof. Abdel-Razzak Mohammad Al-Hinnawi

Faculty of Allied Medical Sciences, Isra University, Amman, Al ‘Āşimah, Jordan
orcid
Isra University, Amman, Jordan

Research Focus & Metrics

Academic Career Length

30Years (1997-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 March 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Roberto de FazioRoberto de Fazio
Roberto de Fazio
Abdel-Razzak Mohammad Al-HinnawiAbdel-Razzak Mohammad Al-Hinnawi
Abdel-Razzak Mohammad Al-Hinnawi
MVMassimo De Vittorio
Massimo De Vittorio
Paolo ViscontiPaolo Visconti
Paolo Visconti
Wearable devices represent a versatile technology in the IoT paradigm, enabling non-invasive and accurate data collection directly from the human body. This paper describes the development of a smart shirt to monitor working conditions in particularly dangerous workplaces. The wearable device integrates a wide set of sensors to locally acquire the user’s vital signs (e.g., heart rate, blood oxygenation, and temperature) and environmental parameters (e.g., the concentration of dangerous gas species and oxygen level). Electrochemical gas-monitoring modules were designed and integrated into the garment for acquiring the concentrations of CO, O2, CH2O, and H2S. The acquired data are wirelessly sent to a cloud platform (IBM Cloud), where they are displayed, processed, and stored. A mobile application was deployed to gather data from the wearable devices and forward them toward the cloud application, enabling the system to operate in areas where a WiFi hotspot is not available. Additionally, the smart shirt comprises a multisource harvesting section to scavenge energy from light, body heat, and limb movements. Indeed, the wearable device integrates several harvesters (thin-film solar panels, thermoelectric generators (TEGs), and piezoelectric transducers), a low-power conditioning section, and a 380 mAh LiPo battery to accumulate the recovered charge. Field tests indicated that the harvesting section could provide up to 216 mW mean power, fully covering the power requirements (P¯ = 1.86 mW) of the sensing, processing, and communication sections in all considered conditions (3.54 mW in the worst-case scenario). However, the 380 mAh LiPo battery guarantees about a 16-day lifetime in the complete absence of energy contributions from the harvesting section.

1 December 2021 in Medical Devices: Evidence and Research
Verified
Journal Article
Open access
PDF file
Bassam Odeh Al-NaamiBassam Odeh Al-Naami
Bassam Odeh Al-Naami
HOHamza Abu Owida
Hamza Abu Owida
MMMohammed Abu Mallouh
Mohammed Abu Mallouh
FAFeras Al-Naimat
Feras Al-Naimat
MAMoh'D Agha
Moh'D Agha
Abdel-Razzak Mohammad Al-HinnawiAbdel-Razzak Mohammad Al-Hinnawi
Abdel-Razzak Mohammad Al-Hinnawi
Purpose: The daily life management of patients with Alzheimer’s disease (AD) constitutes a significant and rapidly expanding health-care responsibility. In this study, an innovative prototype of a wireless-sensing smart wearable medical device (SWMD) is proposed as a multi-functions solution for Alzheimer patients. The SWMD is aimed to assemble three main biomedical engineering advances: 1) use of a Wi-Fi microcontroller, 2) simultaneous monitoring of a set of vital biomarkers, and 3) cautions of fall down conditions, in addition to GPS location indicator. Methods: The SWMD employs a Wi-Fi controller that is incorporated with electronic circuits to monitor three vital signals (temperature, heart rate, and oxygen saturation), fall down conditions in three directions (X, Y, and Z axis), and GPS location. The SWMD was connected to the Firebase Service (database hosted on the Internet Cloud). The proposed device was tested on 13 normal volunteers. The left side, right side, forward, and backward fall down conditions were assessed. The prototype’s functions during daily activity such as rising hand, sitting down or standing up, and walking conditions were also assessed. Results: The three assembled functions were all successfully incorporated to build the SWDM device as a suggested solution offering real-time alerts during daily activity to AD patients. The Bland-Altman statistical test showed no significant difference (p-value > 0.05) between the SWMD biomarkers’ acquisition and the reference methods. The gyro/accelerator sensor yielded 93% sensitivity in fall down detection and 95% specificity during daily activities. The GPS yielded correct positioning of the SWDM holder, while the internet cloud allowed saving and managing all vital biomarkers daily. Conclusion: The SWMD is a possible solution for daily life support for AD patients. It incorporates three functions in one single device, GPS location indicator, monitoring set of biomarkers, and fall down alert, which are all controlled via a Wi-Fi micro controller on-line connected to Internet Cloud. It successfully would allow the management of the daily records as well as the real-time alerts to remote persons.

8 December 2020 in IEEE Access
Verified
Journal Article
Open access
Bassam Odeh Al-NaamiBassam Odeh Al-Naami
Bassam Odeh Al-Naami
HFHossam Fraihat
Hossam Fraihat
NGNasr Y. Gharaibeh
Nasr Y. Gharaibeh
Abdel-Razzak Mohammad Al-HinnawiAbdel-Razzak Mohammad Al-Hinnawi
Abdel-Razzak Mohammad Al-Hinnawi
To investigate the performance of Adaptive Neuro-Fuzzy Inference System (ANFIS), activated by spectral analysis features, for detection of abnormal cardiac valves sound signals. A dataset of 1837 heart sound signals were acquired from international PhysioNet Challenge 2016 databases (classes A, B and E). This included 1369 normal and 468 abnormal signals. The signals were de-noised using Notch and Butterworth filtering, fed to Discrete Fourier Transform, and 5 features using High Order Spectral (HOS) analysis were extracted from the third Cumulant. Later, the ANFIS neural network was trained and tested to discern abnormal signals. The results showed that the selected features were statistically significant (p<0.05). The proposed method was tested and achieved classification of 63-89% accuracy, 63-100% sensitivity, and 62-100% specificity, respectively. The results were compared with reports utilizing different neural network techniques, indicating competitive performance. The HOS spectral features can be reliable to participate in neural network systems to sort heart sound (HS) signals as normal or abnormal. The bispectral matrix is a new presentation of attributes describing signals. The ANFIS is a suggestive successful tool, which has not been attempted in Physio-net challenge 2016. The HOS attributes and ANFIS can participate successfully in PhysioNet Challenge 2016.

15 July 2024 in Journal of Imaging
Verified
Journal Article
Open access
PDF file
NGNasr Gharaibeh
Nasr Gharaibeh
Roberto de FazioRoberto de Fazio
Roberto de Fazio
Bassam Odeh Al-NaamiBassam Odeh Al-Naami
Bassam Odeh Al-Naami
Abdel-Razzak Mohammad Al-HinnawiAbdel-Razzak Mohammad Al-Hinnawi
Abdel-Razzak Mohammad Al-Hinnawi
Paolo ViscontiPaolo Visconti
Paolo Visconti
Accurate prognosis and diagnosis are crucial for selecting and planning lung cancer treatments. As a result of the rapid development of medical imaging technology, the use of computed tomography (CT) scans in pathology is becoming standard practice. An intricate interplay of requirements and obstacles characterizes computer-assisted diagnosis, which relies on the precise and effective analysis of pathology images. In recent years, pathology image analysis tasks such as tumor region identification, prognosis prediction, tumor microenvironment characterization, and metastasis detection have witnessed the considerable potential of artificial intelligence, especially deep learning techniques. In this context, an artificial intelligence (AI)-based methodology for lung cancer diagnosis is proposed in this research work. As a first processing step, filtering using the Butterworth smooth filter algorithm was applied to the input images from the LUNA 16 lung cancer dataset to remove noise without significantly degrading the image quality. Next, we performed the bi-level feature selection step using the Chaotic Crow Search Algorithm and Random Forest (CCSA-RF) approach to select features such as diameter, margin, spiculation, lobulation, subtlety, and malignancy. Next, the Feature Extraction step was performed using the Multi-space Image Reconstruction (MIR) method with Grey Level Co-occurrence Matrix (GLCM). Next, the Lung Tumor Severity Classification (LTSC) was implemented by using the Sparse Convolutional Neural Network (SCNN) approach with a Probabilistic Neural Network (PNN). The developed method can detect benign, normal, and malignant lung cancer images using the PNN algorithm, which reduces complexity and efficiently provides classification results. Performance parameters, namely accuracy, precision, F-score, sensitivity, and specificity, were determined to evaluate the effectiveness of the implemented hybrid method and compare it with other solutions already present in the literature.

17 March 2022 in Electronics
Verified
Journal Article
Open access
PDF file
Bassam Odeh Al-NaamiBassam Odeh Al-Naami
Bassam Odeh Al-Naami
HFhossam fraihat
hossam fraihat
JAJamal Al-Nabulsi
Jamal Al-Nabulsi
NGNasr Gharaibeh
Nasr Gharaibeh
Paolo ViscontiPaolo Visconti
Paolo Visconti
Abdel-Razzak Mohammad Al-HinnawiAbdel-Razzak Mohammad Al-Hinnawi
Abdel-Razzak Mohammad Al-Hinnawi
The research paper proposes a novel denoising method to improve the outcome of heart-sound (HS)-based heart-condition identification by applying the dual-tree complex wavelet transform (DTCWT) together with the adaptive neuro-fuzzy inference System (ANFIS) classifier. The method consists of three steps: first, preprocessing to eliminate 50 Hz noise; second, applying four successive levels of DTCWT to denoise and reconstruct the time-domain HS signal; third, to evaluate ANFIS on a total of 2735 HS recordings from an international dataset (PhysioNet Challenge 2016). The results show that the signal-to-noise ratio (SNR) with DTCWT was significantly improved (p < 0.001) as compared to original HS recordings. Quantitatively, there was an 11% to many decibel (dB)-fold increase in SNR after DTCWT, representing a significant improvement in denoising HS. In addition, the ANFIS, using six time-domain features, resulted in 55–86% precision, 51–98% recall, 53–86% f-score, and 54–86% MAcc compared to other attempts on the same dataset. Therefore, DTCWT is a successful technique in removing noise from biosignals such as HS recordings. The adaptive property of ANFIS exhibited capability in classifying HS recordings.

29 August 2022 in Computers
Verified
Journal Article
Open access
PDF file
AAAhmad A Almazloum
Ahmad A Almazloum
Abdel-Razzak Mohammad Al-HinnawiAbdel-Razzak Mohammad Al-Hinnawi
Abdel-Razzak Mohammad Al-Hinnawi
Roberto de FazioRoberto de Fazio
Roberto de Fazio
Paolo ViscontiPaolo Visconti
Paolo Visconti
The aim of the research work is to investigate the operability of the entire 23 pulmonary function parameters, which are stipulated by the American Thoracic Society (ATS) and the European Respiratory Society (ERS), to design a medical decision support system capable of classifying the pulmonary function tests into normal, obstructive, restrictive, or mixed cases. The 23 respiratory parameters specified by the ATS and the ERS guidelines, obtained from the Pulmonary Function Test (PFT) device, were employed as input features to a Multi-Layer Perceptron (MLP) neural network. Thirteen possible MLP Back Propagation (BP) algorithms were assessed. Three different categories of respiratory diseases were evaluated, namely obstructive, restrictive, and mixed conditions. The framework was applied on 201 PFT examinations: 103 normal and 98 abnormal cases. The PFT decision support system’s outcomes were compared with both the clinical truth (physician decision) and the PFT built-in diagnostic software. It yielded 92–99% and 87–92% accuracies on the training and the test sets, respectively. An 88–94% area under the receiver operating characteristic curve (ROC) was recorded on the test set. The system exceeded the performance of the PFT machine by 9%. All 23 ATS\ERS standard PFT parameters can be used as inputs to design a PFT decision support system, yielding a favorable performance compared with the literature and the PFT machine’s diagnosis program.