The objective of this study is to understand the combined effects of bone quality, implant materials and bodyweight on the biomechanical performance of cemented acetabular cup. Additionally, the performance of the cemented acetabular cup was evaluated for obesity cases or obese people. A total of 84 FE models (based on CT data) were developed based on combinations of three different cancellous bone material distributions to represent bone quality, four different implant material combinations and seven different bodyweights. The biomechanical performance of the acetabular cup was evaluated based on bone stress (both cortical and cancellous bone), cement mantle stress, micromotion and contact pressure between the acetabular cup and femoral head. Cortical bone stress, cancellous bone stress, cement stress, the contact pressure between implants and micromotion between implants are affected by different bone quality, implant material combinations and bodyweights. An increase in bodyweight would increase the cortical bone stress, cancellous bone stress, cement stress, contact pressure between implants and micromotion between implants. However, bodyweight affects the cortical and cancellous bone stress more (stiff rise of the bone stresses; nonlinear relation) as compared to other output parameters (mostly linear relation). Comparing cortical and cancellous bone stress, the stress versus bodyweight curve is much stiffer (stiff rise in the curve) for cortical bone than cancellous bone and that even further increases as bone quality decreases. Especially considering obesity cases or obese people (very high bodyweight), the performance of the cemented acetabular component is poor. Graphical [ ]
1 September 2021 in Engineering Fracture Mechanics
Similar to how fiber orientation affects composite materials, osteon orientation affects the elasticity and fracture behavior of cortical bone. The objective of this work is to predict the combined effect of orientations of the osteon, applied load, and various crack lengths on the fracture characteristics of cortical bone. Orthotropic modeling and analyses of cortical bone were carried out using the linear-elastic fracture mechanics (LEFM) based extended finite element method (XFEM). Five values of applied mode-I and mode-II load, five distinct crack lengths, and seven angular osteon orientations were taken into consideration to predict the change in SIF. In this work, the 2-D plane stress assumption with a straight-edge crack was taken into consideration. It was found that the values of SIF significantly increased when the load (15–35 MPa) and fracture length (1.8–2.2 mm) increased. SIF ( KI) values under mode-I loading were discovered to be substantially lower than SIF ( KI and KII) values under mode-II loading. Results of this study showed that osteon orientations with different crack lengths and applied loads had a significant impact on cortical bone fracture characteristics. Only the crack’s opening was discovered to be caused by mode-I loading; however, both the opening and shearing of the crack were found to be caused by mode-II loading. Despite differences in applied loads, crack lengths, and osteon orientations, the values of the SIF predicted in this work (under mode-I loading) using LEFM-based XFEM exhibited good agreement with the prior published experimental and numerical data.