Masume Khodsuz

Dr. Masume Khodsuz


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 January 2024 in IET Generation, Transmission & Distribution
Verified
Journal Article
Open access
MKMasume Khodsuz
Masume Khodsuz
MTMohammad Hossein Teymourian
Mohammad Hossein Teymourian
SSSeyyedmeysam Seyyedbarzegar
Seyyedmeysam Seyyedbarzegar
The role of surge arresters is vital in power systems' protection against transient overvoltages, which can arise due to occurrences like lightning strikes or switching operations. Based on the performance of the surge arrester, assessing its condition is an essential requirement for early detection of any damage or deterioration. This article proposes innovative criteria based on the surge arresters’ leakage current analysis for the classification of uniform and non‐uniform pollution levels. The leakage current signal of clean, uniform, and non‐uniform polluted surge arresters has been examined under different contamination levels, humidity, and non‐uniformity degrees. Based on the experimental results analysis, a new criterion has been proposed for assessing the surge arrester condition, which has resulted from the fifth and first‐order harmonics ratio of resistive leakage current. Analysis of the proposed criterion demonstrates that this index has a significant correlation to the pollution level. The proposed criterion ability has been established based on random forest, support vector machine, decision tree algorithm, and multi‐layer perceptron in Python language. The obtained criterion based on experimental data in different conditions has been employed for classifier training, which can be applied in the power network for better condition monitoring of surge arresters ensuring fast and accurate outcomes.

19 March 2024 in Engineering Applications of Artificial Intelligence
Verified
Journal Article
Closed access
MKMasume Khodsuz
Masume Khodsuz
SZSeyed Alireza Zamani
Seyed Alireza Zamani

21 February 2022 in Energies
Verified
Journal Article
Open access
PDF file
RTRohollah Tamaskani
Rohollah Tamaskani
MKMasume Khodsuz
Masume Khodsuz
Mohammad Yazdani AsramiMohammad Yazdani Asrami
Mohammad Yazdani Asrami
This paper aims to find the optimal size of parameters of a C-type filter in a non-sinusoidal system using a new optimization method called the Archimedes optimization algorithm (AOA). The inductance and capacitance values of the filter are acquired in which the power loss in the Thevenin resistor and the power loss characteristics of the load bus are minimized based on a new proposed objective function. Subject to technical and practical limitations of the IEEE 519 standard, an optimization problem is defined to achieve an optimal filter design that can increase the system power quality. The effectiveness of the proposed method is proved by comparison with the recent previously published methods. The results show the effectiveness of the proposed approach using the AOA in finding the minimum power losses and the harmonic content of frequency-dependent components. Eventually, the current study confirmed that the suggested objective function minimizes power losses of fundamental and harmonic order harmonics in non-sinusoidal systems.

15 December 2023 in IEEE Transactions on Dielectrics and Electrical Insulation
Verified
Journal Article
Closed access
MTMohammad Hossien Teymourian
Mohammad Hossien Teymourian
SSSeyyedmeysam Seyyedbarzegar
Seyyedmeysam Seyyedbarzegar
MKMasume Khodsuz
Masume Khodsuz
This paper investigates the leakage current (LC) analysis of metal oxide surge arresters (MOSA) under both uniform and fan-shape as a non-uniform pollution conditions and at different humidity levels (H), through experimental methods. The main contribution of the paper is examining the effect of fan-shape pollution on MOSA leakage current. Increasing the degree of non-uniformity (D) decreases the MOSA leakage current and its harmonic components. The experimental results show that D has a greater impact on reducing the harmonic components of the resistive leakage current, with a lesser effect on the fifth-order harmonic (Ir5) compared to the first (Ir1) and third-order harmonics (Ir3). The first, third, and fifth-order harmonics of the resistive leakage current demonstrate an approximate linear relationship with D. Therefore, D can influence on condition monitoring criteria, potentially leading to incorrect diagnosis of the MOSA condition. For instance, variation of pollution from uniform to D = 0.75 causes a two-fold decrease in the Ir3/Ir5 criterion.

28 December 2023 in IET Science, Measurement & Technology
Verified
Journal Article
Open access
MEMehdi Esmaieli
Mehdi Esmaieli
MKMasume Khodsuz
Masume Khodsuz
HNHassan Nouri
Hassan Nouri
The leakage current characteristic monitoring of transmission line insulators is considered a worthy technique for insulator state prediction. In this paper, the harmonic analysis of leakage current signals has been performed to analyze the composite insulator condition. Experimental studies of asymmetrically aged, fully aged, and virgin insulators have been conducted. The effects of different aging types, pollution, and humidity on leakage current components, such as harmonics and the phase differences with the applied voltage, have been investigated. The analysis of the results shows that the effect of asymmetric aging on leakage current components is non‐linear, and this non‐linearity increases with the degree of pollution. Also, the type of insulator aging can be determined by the ratio of the third‐ and fifth‐order leakage current harmonics. For instance, the classification of insulators into virgin, asymmetrically aged, and fully aged can be determined by examining the corresponding value ranges of 0–0.5, 0.5–0.9, and > 0.9, respectively. Similarly, the phase difference values of < 15% and those > 15% indicate the clean and polluted operating conditions individually.

12 October 2023 in IET Generation, Transmission & Distribution
Verified
Journal Article
Open access
MKMasume Khodsuz
Masume Khodsuz
This paper conducts the frequency‐dependent grounding system impact on externally gapped line arresters (EGLAs) operation and their placement effects on the lightning performance of a transmission line (TL). The study involves placing EGLAs at different phases of a 400‐kV double‐circuit TL with two downstream shield wires and selecting the optimal state with fewer back‐flashover incidents. The results show that using a non‐linear grounding system leads to a higher back return current from insulators or EGLAs, resulting in a higher flashover rate compared to the frequency grounding system (FGS). Installing four EGLAs in the middle and upper phases of the TL provides satisfactory lightning protection, and the flashover probability is zero and 4.2% for the FGS and the non‐linear grounding system, respectively. A sensitivity analysis including soil resistor variation, economic analysis, and grounding electrode configuration has been performed that confirms installing downstream shield wires and EGLAs is an effective and economical technique for lightning protection.