The role of surge arresters is vital in power systems' protection against transient overvoltages, which can arise due to occurrences like lightning strikes or switching operations. Based on the performance of the surge arrester, assessing its condition is an essential requirement for early detection of any damage or deterioration. This article proposes innovative criteria based on the surge arresters’ leakage current analysis for the classification of uniform and non‐uniform pollution levels. The leakage current signal of clean, uniform, and non‐uniform polluted surge arresters has been examined under different contamination levels, humidity, and non‐uniformity degrees. Based on the experimental results analysis, a new criterion has been proposed for assessing the surge arrester condition, which has resulted from the fifth and first‐order harmonics ratio of resistive leakage current. Analysis of the proposed criterion demonstrates that this index has a significant correlation to the pollution level. The proposed criterion ability has been established based on random forest, support vector machine, decision tree algorithm, and multi‐layer perceptron in Python language. The obtained criterion based on experimental data in different conditions has been employed for classifier training, which can be applied in the power network for better condition monitoring of surge arresters ensuring fast and accurate outcomes.
15 December 2023 in IEEE Transactions on Dielectrics and Electrical Insulation
This paper investigates the leakage current (LC) analysis of metal oxide surge arresters (MOSA) under both uniform and fan-shape as a non-uniform pollution conditions and at different humidity levels (H), through experimental methods. The main contribution of the paper is examining the effect of fan-shape pollution on MOSA leakage current. Increasing the degree of non-uniformity (D) decreases the MOSA leakage current and its harmonic components. The experimental results show that D has a greater impact on reducing the harmonic components of the resistive leakage current, with a lesser effect on the fifth-order harmonic (Ir5) compared to the first (Ir1) and third-order harmonics (Ir3). The first, third, and fifth-order harmonics of the resistive leakage current demonstrate an approximate linear relationship with D. Therefore, D can influence on condition monitoring criteria, potentially leading to incorrect diagnosis of the MOSA condition. For instance, variation of pollution from uniform to D = 0.75 causes a two-fold decrease in the Ir3/Ir5 criterion.
28 February 2024 in Physica C: Superconductivity and its Applications
Al2O3 nanoparticles were used to improve the performance of the vital properties of transformer oil (TO) under normal operating conditions and when subjected to thermal aging. Different weight percentages of Al2O3 in the TO were considered to maximize the breakdown voltage (BDV). Al2O3 nanofluid (NF) increases the BDV by 116% (31.1 kV to 67.4 kV) and the heat transfer by 33.4%, and also minimizes partial discharge (PD) by 66%. The reduction of PD is also related to the ability of Al2O3 to adsorb hydrogen and acetylene, two oil-soluble gases that are effective in PD. Even Al2O3NF was more resistant to water content in TO. BDV for TO and Al2O3NF, when water content increased to more than 30 ppm, were reduced by 57% and 19%, respectively. According to Arrhenius equation, both samples were placed at 120°C for 29 days to age samples (equivalent to about 30 years). Aged Al2O3NF has continued its exceptional performance and improved BDV by 121% compared to aged TO, and also Al2O3NF showed its capacity well and improved PD compared to aged TO by 71%. All the favorable properties of Al2O3NF are conditional on the stability of Al2O3. FESEM confirms the stability of Al2O3.