Torleif Dahlin

Prof. Torleif Dahlin

orcid

Research Focus & Metrics

Academic Career Length

28Years (1999-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 August 2004 in Geophysical Prospecting
Verified
Journal Article
Closed access
PDF file
TDTorleif Dahlin
Torleif Dahlin
MWMoosoo Won
Moosoo Won

1 August 2017 in Journal of Applied Geophysics
Verified
Journal Article
Closed access
KHKristofer Hellman
Kristofer Hellman
MRMathias Ronczka
Mathias Ronczka
TGThomas Günther
Thomas Günther
MWMarcus Wennermark
Marcus Wennermark
CRCarsten Rücker
Carsten Rücker
TDTorleif Dahlin
Torleif Dahlin

16 November 2016 in Geosciences
Verified
Journal Article
Open access
PDF file
AAAndres Saul Gonzales Amaya
Andres Saul Gonzales Amaya
TDTorleif Dahlin
Torleif Dahlin
GBGerhard Barmen
Gerhard Barmen
JRJan-Erik Rosberg
Jan-Erik Rosberg
Conceptual models of aquifer systems can be refined and complemented with geophysical data, and they can assist in understanding hydrogeological properties such as groundwater storage capacity. This research attempts to use geoelectrical methods, Electrical Resistivity Tomography and Induced Polarization parameters, for mapping the subsurface in alluvial fans and to demonstrate its applicability; the Punata alluvial fan was used as a case study. The resistivity measurements proved to be a good tool for mapping the subsurface in the fan, especially when used in combination with Induced Polarization parameters (i.e., Normalized Chargeability). The Punata alluvial fan characterization indicated that the top part of the subsurface is composed of boulders in a matrix of finer particles and that the grain size decreases with depth; the electrical resistivity of these deposits ranged from 200 to 1000 Ωm, while the values of normalized chargeability were lower than 0.05 mS/m. The bottom of the aquifer system consisted of a layer with high clay content, and the resistivity ranged from 10 to 100 Ωm, while the normalized chargeability is higher than 0.07 mS/m. With the integration of these results and lithological information, a refined conceptual model is proposed; this model gives a more detailed description of the local aquifer system. It can be concluded that geoelectrical methods are useful for mapping aquifer systems in alluvial fans.

10 November 2005 in Environmental Geology
Verified
Journal Article
Closed access
PDF file
VLVirginie Leroux
Virginie Leroux
TDTorleif Dahlin
Torleif Dahlin


1 January 2016 in Geophysics
Verified
Journal Article
Open access
STSoňa Tomaškovičová
Soňa Tomaškovičová
Thomas Ingeman-NielsenThomas Ingeman-Nielsen
Thomas Ingeman-Nielsen
ACAnders Vest Christiansen
Anders Vest Christiansen
IBInooraq Brandt
Inooraq Brandt
TDTorleif Dahlin
Torleif Dahlin
BEBo Elberling
Bo Elberling
Although electric resistivity tomography (ERT) is now regarded as a standard tool in permafrost monitoring, high grounding resistances continue to limit the acquisition of time series over complete freeze-thaw cycles. In an attempt to alleviate the grounding resistance problem, we have tested three electrode designs featuring increasing sizes and surface area, in the laboratory and at three different field sites in Greenland. Grounding resistance measurements showed that changing the electrode shape (using plates instead of rods) reduced the grounding resistances at all sites by 28%–69% during unfrozen and frozen ground conditions. Using meshes instead of plates (the same rectangular shape and a larger effective surface area) further improved the grounding resistances by 29%–37% in winter. Replacement of rod electrodes of one entire permanent permafrost monitoring array by meshes resulted in an immediate reduction of the average grounding resistance by 73% from 1.5 to 0.4 kΩ (unfrozen conditions); in addition, the length of the acquisition period during the winter season was markedly prolonged. Grounding resistance time series from the three ERT monitoring stations in Greenland showed that the electrodes were rarely perfectly grounded and that grounding resistances exceeding 1 MΩ may occur in severe cases. We concluded that the temperature, electrode shape, and lithology at the sites have a marked impact on electrode performance. Choosing an optimized electrode design may be the deciding factor for successful data acquisition, and should therefore be considered when planning a long-term monitoring project.