Aliasghar Ajami

Dr. Aliasghar Ajami

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 May 2018 in Polymer Chemistry
Verified
Journal Article
Closed access
PDF file
MTMaximilian Tromayer
Maximilian Tromayer
ADAgnes Dobos
Agnes Dobos
PGPeter Gruber
Peter Gruber
AAAliasghar Ajami
Aliasghar Ajami
RDRoman Dedic
Roman Dedic
RLRobert Liska
Robert Liska
Direct cell encapsulation is a powerful tool for fabrication of biomimetic 3D cell culture models in vitro. This method allows more precise recapitulation of the natural environment and physiological functions of cells compared to classical 2D cultures. In contrast to seeding cells on prefabricated scaffolds, cell encapsulation offers benefits regarding high initial cell loading, uniformity of cell distribution and more defined cell–matrix contact. Two-photon polymerization (2PP) based 3D printing enables the precise engineering of cell-containing hydrogel constructs as tissue models. Two-photon initiators (2PIs) specifically developed for this purpose still exhibit considerable cyto- and phototoxicity, impairing the viability of encapsulated cells. This work reports the development of the first cleavable diazosulfonate 2PI DAS, largely overcoming these limitations. The material was characterized by standard spectroscopic methods, white light continuum two-photon absorption cross-section measurements, and its photosensitization of cytotoxic singlet oxygen was compared to the well-established 2PI P2CK. When DAS is used at double concentration to compensate for the lower two-photon cross section, its performance in 2PP-printing of hydrogels is similar to P2CK based on structuring threshold and structure swelling measurements. PrestoBlue metabolic assay showed vastly improved cytocompatibility of DAS in 2D. Cell survival in 3D direct encapsulation via 2PP was up to five times higher versus P2CK, further demonstrating the excellent biocompatibility of DAS and its potential as superior material for laser-based biofabrication.

14 July 2024 in Applied Physics B
Verified
Journal Article
Closed access
PDF file
AAAliasghar Ajami
Aliasghar Ajami
AOAleksandr Ovsianikov
Aleksandr Ovsianikov
RLRobert Liska
Robert Liska
SBStefan Baudis
Stefan Baudis

8 September 2020 in Journal of the Optical Society of America B
Verified
Journal Article
Closed access
SBShazia Bashir
Shazia Bashir
MRMuhammad Shahid Rafique
Muhammad Shahid Rafique
CNChandra Sekher Reddy Nathala
Chandra Sekher Reddy Nathala
AAAliasghar Ajami
Aliasghar Ajami
WHWolfgang Husinsky
Wolfgang Husinsky
RARafiq
Rafiq
This paper reports on the effect of both the pulse duration and environments on the surface morphology, ablated area, ablation rate, and mechanical properties of a femtosecond laser irradiated zinc (Zn) in air and ethanol. The targets were exposed to 1000 succeeding pulses of Ti:sapphire laser (800 nm) at a fluence of 2.5 J c m − 2 with various pulse durations ranging from 30 to 550 fs. The surface structures have been characterized by a field emission scanning electron microscope, whereas the ablation rate has been measured using confocal and optical microscopy. The mechanical behavior of irradiated targets has been explored by using a microhardness tester. It is observed that in the case of Zn ablation in air, a crater with nonuniform surface morphology along with formation of both micro- and nanoscale droplets rims, organized laser-induced periodic surfaces are observed, whereas in the case of ablation in ethanol, nano- and microscale scale droplets, pores, cones, agglomerates, and channels are formed. The growth and the shape of these structures are strongly dependent on the pulse durations and environments. The hardness of laser-treated samples is found to be higher as compared to untreated ones and is also found higher for liquid-assisted ablated Zn as compared to air-assisted ablated targets due to an increased chemical reactivity in an ethanol-confined environment. The decreasing trend of hardness with increasing pulse duration for both environments is observed, which is attributed to decreasing trend in both shock pressure and ablation pressure with increasing pulse duration.

1 January 2020 in Journal of Clinical and Experimental Dentistry
Verified
Journal Article
Open access
MEM. Ebrahimi-Chaharom
M. Ebrahimi-Chaharom
LSL. Safyari
L. Safyari
HSH. Safarvand
H. Safarvand
EJE. Jafari-Navimipour
E. Jafari-Navimipour
POParnian Alizadeh Oskuee
Parnian Alizadeh Oskuee
MBM. Bahari
M. Bahari
The present study was aimed to evaluate the effect of pre-heating of bulk -fill resin composites on monomer elution from them. Three different types of resin composites were used including Tetric N-Ceram Bulk Fill, X-tra Fill and X-tra Base. 10 cylindrical samples were prepared from each resin composites. Before light curing, 5 samples were pre-heated until reaching 68˚C, then 5 other samples were polymerized at room temperature. After 24 hours, release of UDMA, TEGDMA and BIS-GMA monomers were measured by High-Performance Liquid Chromatography analysis. Data analysis was performed by two-way ANOVA test, Games-Howell and Sidak post hoc tests. Pre-heating did not have any statistically significant effect on the mean values of UDMA, TEGDMA and Bis-GMA elution (p>0.05). The greatest amount of released Bis-GMA and UDMA was obtained from Tetric N-Ceram Bulk-fill composite. The greatest amount of released TEGDMA was obtained from X-tra Fill composite. X-tra Base composite showed the lowest amount of monomer release (P<0.001). Pre-heating did not have any effect on monomer release from bulk-fill resin composites. Moreover, the amount and the type of monomers released from various bulk-fill resin composites were not similar. Key words:Bulk fill composite resin, elution, HPLC, residual monomer, temperature.

22 June 2018 in Applied Physics B
Verified
Journal Article
Open access
PDF file
AAAliasghar Ajami
Aliasghar Ajami
WHWolfgang Husinsky
Wolfgang Husinsky
AOAleksandr Ovsianikov
Aleksandr Ovsianikov
RLRobert Liska
Robert Liska
We present an experimental technique to determine the degenerate two-photon absorption (2PA) spectra by performing a single Z-scan using a high-spectral-irradiance white light continuum (WLC) generated by a hollow core fiber. The hollow fiber was filled with Argon (Ar) gas at a pressure of 0.6 bar and was pumped with 500 mJ, 30 fs, and 800 nm pulses. The broadband WLC pulses with 350 nm bandwidth in the range of 600–950 nm were compressed to sub-8 fs pulses. To characterize and interpret the data obtained from this method, the spectral, temporal and spatial characteristics of the WLC were first analyzed. The WLC emerging from the compressor was dispersed using a prism pair and then focused into the sample by a cylindrical lens. Since different spectral components are spatially separated, any part of the sample in the beam cross section is irradiated with almost single wavelength pulses leading to only a degenerate 2PA process. The nonlinear transmittance was then measured by a charge-coupled-device (CCD) line camera as a function of the sample position while the sample was moved along the beam direction by a motorized translation stage. In this way the Z-scans at different wavelengths in the WLC spectral range can be measured and thus the wavelength-resolved degenerate 2PA spectra can be obtained by performing a single scan using dispersive WLC. This method was verified on a well-characterized dye Rhodamine B and yield a reasonable agreement with the data found in the literature. We used this method to determine the 2PA spectra of some two-photon initiators (2PIs) developed for two-photon polymerization (2PP) based 3D micro-structuring.

24 February 2026 in SSRN Electronic Journal
Verified
Preprint
Open access
AAAliasghar Ajami
Aliasghar Ajami
SMSoodabeh Moniri
Soodabeh Moniri
This work demonstrates the capability of pulsed UV laser stereolithography (SLA) for surface texturing with controllable micro-topographies. Rather than emphasizing analytical modeling, this study focuses on numerical calculations and experimental validation to reveal how pulse repetition rate (PRR), scanning speed, and average laser power collectively determine the morphology of polymerized structures on a transparent substrate. A modified exposure model, adapted from existing continuous-wave SLA formulations, was employed to numerically predict the curing profiles produced under dynamic, pulsed irradiation. The numerical calculations show that increasing PRR enhances pulse overlap, resulting in smoother and more uniform polymer lines, while higher pulse energy or average power deepens the cured regions and promotes the coalescence of isolated hillocks into continuous ribbons. Experiments conducted using a custom-built pulsed SLA setup confirmed these predictions. Field-emission scanning electron microscopy (FESEM) and optical microscopy analyses revealed a consistent morphological evolution, from discrete micro-hillocks to merged, saw-tooth, and finally ribbon-like structures, matching the numerically calculated profiles. The control of PRR, scanning speed, and average laser power directly governs the lateral and vertical curing dimensions, as confirmed by numerical calculations and experiment. Consequently, this method allows for the straightforward creation of tailored surface topographies, including hillocks and craters with dimensions from tens to hundreds of microns. This combined numerical–experimental approach highlights pulsed SLA as a promising tool for designing functional microtextures for optical, and biomedical applications.