Roman Kamnik

Prof. Dr. Roman Kamnik

orcid

Research Focus & Metrics

Academic Career Length

29Years (1998-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2014 in Computer Methods and Programs in Biomedicine
Verified
Journal Article
Closed access
SŠSebastjan Šlajpah
Sebastjan Šlajpah
RKRoman Kamnik
Roman Kamnik
MMMarko Munih
Marko Munih

3 June 2016 in Sensors
Verified
Journal Article
Open access
PDF file
Gianmarco BaldiniGianmarco Baldini
Gianmarco Baldini
GSGary Steri
Gary Steri
FDFranc Dimc
Franc Dimc
RGRaimondo Giuliani
Raimondo Giuliani
RKRoman Kamnik
Roman Kamnik
The correct identification of smartphones has various applications in the field of security or the fight against counterfeiting. As the level of sophistication in counterfeit electronics increases, detection procedures must become more accurate but also not destructive for the smartphone under testing. Some components of the smartphone are more likely to reveal their authenticity even without a physical inspection, since they are characterized by hardware fingerprints detectable by simply examining the data they provide. This is the case of MEMS (Micro Electro-Mechanical Systems) components like accelerometers and gyroscopes, where tiny differences and imprecisions in the manufacturing process determine unique patterns in the data output. In this paper, we present the experimental evaluation of the identification of smartphones through their built-in MEMS components. In our study, three different phones of the same model are subject to repeatable movements (composing a repeatable scenario) using an high precision robotic arm. The measurements from MEMS for each repeatable scenario are collected and analyzed. The identification algorithm is based on the extraction of the statistical features of the collected data for each scenario. The features are used in a support vector machine (SVM) classifier to identify the smartphone. The results of the evaluation are presented for different combinations of features and Inertial Measurement Unit (IMU) outputs, which show that detection accuracy of higher than 90% is achievable.

14 March 2005 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Closed access
RKRoman Kamnik
Roman Kamnik
JSJian Qing Shi
Jian Qing Shi
RMRoderick Murray-Smith
Roderick Murray-Smith
TBT. Bajd
T. Bajd
This paper presents analysis of the standing-up manoeuvre in paraplegia considering the body supportive forces as a potential feedback source in functional electrical stimulation (FES)-assisted standing-up. The analysis investigates the significance of arm, feet, and seat reaction signals to the human body center-of-mass (COM) trajectory reconstruction. The standing-up behavior of eight paraplegic subjects was analyzed, measuring the motion kinematics and reaction forces to provide the data for modeling. Two nonlinear empirical modeling methods are implemented-Gaussian process (GP) priors and multilayer perceptron artificial neural networks (ANN)-and their performance in vertical and horizontal COM component reconstruction is compared. As the input, ten sensory configurations that incorporated different number of sensors were evaluated trading off the modeling performance for variables chosen and ease-of-use in everyday application. For the purpose of evaluation, the root-mean-square difference was calculated between the model output and the kinematics-based COM trajectory. Results show that the force feedback in COM assessment in FES assisted standing-up is comparable alternative to the kinematics measurement systems. It was demonstrated that the GP provided better modeling performance, at higher computational cost. Moreover, on the basis of averaged results, the use of a sensory system incorporating a six-dimensional handle force sensor and an instrumented foot insole is recommended. The configuration is practical for realization and with the GP model achieves an average accuracy of COM estimation 16 /spl plusmn/ 1.8 mm in horizontal and 39 /spl plusmn/ 3.7 mm in vertical direction. Some other configurations analyzed in the study exhibit better modeling accuracy, but are less practical for everyday usage.

21 January 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
AMAna Mandeljc
Ana Mandeljc
ARAleksander Rajhard
Aleksander Rajhard
MMMarko Munih
Marko Munih
RKRoman Kamnik
Roman Kamnik
Due to the ageing population and an increasing number of stroke patients, we see the potential future of rehabilitation in telerehabilitation, which might alleviate the workload of physiotherapists and occupational therapists. In order to enable the use of telerehabilitation, devices aimed for home and independent use need to be developed. This paper describes the design of a robotic device for post-stroke wrist and finger rehabilitation and evaluates the movement it can perform. Six healthy subjects were tested in three experimental conditions: performing a coupled movement of wrist and fingers from flexion to extension without the device, with a passive device, and with an active device. The kinematics of the hand were captured using three Optotrak Certus motion capture systems and tracking 11 infrared active light-emitting diode (LED) markers. The results are presented in the form of base-line trajectories for all middle finger (MF) joints. In addition, the deviations of trajectories between conditions across all subjects were computed for the metacarpophalangeal (MCP) joint and fingertip of the MF and pinkie (PF) finger. Deviations from the base-line trajectory between measurement protocols and the root-mean-square deviation (RMSD) values indicate that the motion of the hand, imposed by the developed device, is comparable to the unconstrained motion of the healthy subjects, especially when moving into the extension, opening the hand.

28 November 2021 in Electronics
Verified
Journal Article
Open access
PDF file
SKStanko Kružić
Stanko Kružić
Josip MusicJosip Music
Josip Music
RKRoman Kamnik
Roman Kamnik
Vladan PapićVladan Papić
Vladan Papić
When a mobile robotic manipulator interacts with other robots, people, or the environment in general, the end-effector forces need to be measured to assess if a task has been completed successfully. Traditionally used force or torque estimation methods are usually based on observers, which require knowledge of the robot dynamics. Contrary to this, our approach involves two methods based on deep neural networks: robot end-effector force estimation and joint torque estimation. These methods require no knowledge of robot dynamics and are computationally effective but require a force sensor under the robot base. Several different architectures were considered for the tasks, and the best ones were identified among those tested. First, the data for training the networks were obtained in simulation. The trained networks showed reasonably good performance, especially using the LSTM architecture (with a root mean squared error (RMSE) of 0.1533 N for end-effector force estimation and 0.5115 Nm for joint torque estimation). Afterward, data were collected on a real Franka Emika Panda robot and then used to train the same networks for joint torque estimation. The obtained results are slightly worse than in simulation (0.5115 Nm vs. 0.6189 Nm, according to the RMSE metric) but still reasonably good, showing the validity of the proposed approach.

6 October 2017 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Closed access
SŠSebastjan Šlajpah
Sebastjan Šlajpah
RKRoman Kamnik
Roman Kamnik
MMMarko Munih
Marko Munih
The direction of the Earth's magnetic field is used as a reference vector to determine the heading in orientation estimation with wearable sensors. However, the magnetic field strength is weak and can be easily disturbed in the vicinity of ferromagnetic materials, which may result in inaccurate estimate of orientation. This paper presents a novel method for estimating and compensating for magnetic disturbances. The compensation algorithm is implemented within a kinematic-based extended Kalman filter and is based on an assessment of the magnetic disturbance and the change of orientation in each time step. The proposed algorithm was experimentally validated by measuring the orientation of a simple mechanical system with three degrees of freedom in an artificially disturbed magnetic field. The results of the experimental evaluation show that an Kalman filter algorithm that incorporates compensating for magnetic disturbances is capable of estimating the orientation with moderate error (the absolute median errors Δθ̃ X , Δθ̃ Z <; 2°, Δθ̃ Y <; 9°) when the Earth's magnetic field is disturbed by magnetic disturbance with a magnitude equal to twice the magnitude of the Earth's own magnetic field in different directions.