Marko Munih

Prof. Dr. Marko Munih

orcid

Research Focus & Metrics

Academic Career Length

35Years (1992-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 February 2014 in Sensors
Verified
Journal Article
Open access
PDF file
MGMaja Goršič
Maja Goršič
RKRoman Kamnik
Roman Kamnik
LALuka Ambrozic
Luka Ambrozic
NVNicola Vitiello
Nicola Vitiello
DLDirk Lefeber
Dirk Lefeber
MMMarko Munih
Marko Munih
This paper presents a gait phase detection algorithm for providing feedback in walking with a robotic prosthesis. The algorithm utilizes the output signals of a wearable wireless sensory system incorporating sensorized shoe insoles and inertial measurement units attached to body segments. The principle of detecting transitions between gait phases is based on heuristic threshold rules, dividing a steady-state walking stride into four phases. For the evaluation of the algorithm, experiments with three amputees, walking with the robotic prosthesis and wearable sensors, were performed. Results show a high rate of successful detection for all four phases (the average success rate across all subjects >90%). A comparison of the proposed method to an off-line trained algorithm using hidden Markov models reveals a similar performance achieved without the need for learning dataset acquisition and previous model training.

6 March 2020 in Sensors
Verified
Journal Article
Open access
PDF file
EMElena Martini
Elena Martini
Tommaso FiumalbiTommaso Fiumalbi
Tommaso Fiumalbi
FDFilippo Dell’agnello
Filippo Dell’agnello
Zoran IvanićZoran Ivanić
Zoran Ivanić
MMMarko Munih
Marko Munih
SCSimona Crea
Simona Crea
Wearable robotic devices require sensors and algorithms that can recognize the user state in real-time, in order to provide synergistic action with the body. For devices intended for locomotion-related applications, shoe-embedded sensors are a common and convenient choice, potentially advantageous for performing gait assessment in real-world environments. In this work, we present the development of a pair of pressure-sensitive insoles based on optoelectronic sensors for the real-time estimation of temporal gait parameters. The new design makes use of a simplified sensor configuration that preserves the time accuracy of gait event detection relative to previous prototypes. The system has been assessed relatively to a commercial force plate recording the vertical component of the ground reaction force (vGRF) and the coordinate of the center of pressure along the so-called progression or antero-posterior plane (CoPAP) in ten healthy participants during ground-level walking at two speeds. The insoles showed overall median absolute errors (MAE) of 0.06 (0.02) s and 0.04 (0.02) s for heel-strike and toe-off recognition, respectively. Moreover, they enabled reasonably accurate estimations of the stance phase duration (2.02 (2.03) % error) and CoPAP profiles (Pearson correlation coefficient with force platform ρCoP = 0.96 (0.02)), whereas the correlation with vGRF measured by the force plate was lower than that obtained with the previous prototype (ρvGRF = 0.47 (0.20)). These results confirm the suitability of the insoles for online sensing purposes such as timely gait phase estimation and discrete event recognition.

15 January 2013 in Sensors
Verified
Journal Article
Open access
PDF file
MDMarco Donati
Marco Donati
NVNicola Vitiello
Nicola Vitiello
SRStefano Marco Maria De Rossi
Stefano Marco Maria De Rossi
TLTommaso Lenzi
Tommaso Lenzi
SCSimona Crea
Simona Crea
MCMaria Chiara Carrozza
Maria Chiara Carrozza
We present a sensor technology for the measure of the physical human-robot interaction pressure developed in the last years at Scuola Superiore Sant’Anna. The system is composed of flexible matrices of opto-electronic sensors covered by a soft silicone cover. This sensory system is completely modular and scalable, allowing one to cover areas of any sizes and shapes, and to measure different pressure ranges. In this work we present the main application areas for this technology. A first generation of the system was used to monitor human-robot interaction in upper- (NEUROExos; Scuola Superiore Sant’Anna) and lower-limb (LOPES; University of Twente) exoskeletons for rehabilitation. A second generation, with increased resolution and wireless connection, was used to develop a pressure-sensitive foot insole and an improved human-robot interaction measurement systems. The experimental characterization of the latter system along with its validation on three healthy subjects is presented here for the first time. A perspective on future uses and development of the technology is finally drafted.

22 August 2018 in Sensors
Verified
Journal Article
Open access
PDF file
EREva Repnik
Eva Repnik
UPUrška Puh
Urška Puh
NGNika Goljar
Nika Goljar
MMMarko Munih
Marko Munih
MMMatjaž Mihelj
Matjaž Mihelj
In patients after stroke, ability of the upper limb is commonly assessed with standardised clinical tests that provide a complete upper limb assessment. This paper presents quantification of upper limb movement during the execution of Action research arm test (ARAT) using a wearable system of inertial measurement units (IMU) for kinematic quantification and electromyography (EMG) sensors for muscle activity analysis. The test was executed with each arm by a group of healthy subjects and a group of patients after stroke allocated into subgroups based on their clinical scores. Tasks were segmented into movement and manipulation phases. Each movement phase was quantified with a set of five parameters: movement time, movement smoothness, hand trajectory similarity, trunk stability, and muscle activity for grasping. Parameters vary between subject groups, between tasks, and between task phases. Statistically significant differences were observed between patient groups that obtained different clinical scores, between healthy subjects and patients, and between the unaffected and the affected arm unless the affected arm shows normal performance. Movement quantification enables differentiation between different subject groups within movement phases as well as for the complete task. Spearman’s rank correlation coefficient shows strong correlations between patient’s ARAT scores and movement time as well as movement smoothness. Weak to moderate correlations were observed for parameters that describe hand trajectory similarity and trunk stability. Muscle activity correlates well with grasping activity and the level of grasping force in all groups.

1 September 2014 in Computer Methods and Programs in Biomedicine
Verified
Journal Article
Closed access
SŠSebastjan Šlajpah
Sebastjan Šlajpah
RKRoman Kamnik
Roman Kamnik
MMMarko Munih
Marko Munih

21 May 2008 in Simulation Modelling Practice and Theory
Verified
Journal Article
Closed access
Josip MusicJosip Music
Josip Music
RKRoman Kamnik
Roman Kamnik
MMMarko Munih
Marko Munih