Hao Zhang

Prof. Dr. Hao Zhang

orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 March 2024 in Coordination Chemistry Reviews
Verified
Journal Article
Closed access
GCGuo-Ying Chen
Guo-Ying Chen
TCTong-Qing Chai
Tong-Qing Chai
HZHao Zhang
Hao Zhang
Feng-Qing YangFeng-Qing Yang
Feng-Qing Yang

17 October 2022 in Microchimica Acta
Verified
Journal Article
Closed access
PDF file
HZHang-Yu Zhou
Hang-Yu Zhou
LPLi-Jing Peng
Li-Jing Peng
TTTao Tian
Tao Tian
WZWei-Yi Zhang
Wei-Yi Zhang
GCGuo-Ying Chen
Guo-Ying Chen
Feng-Qing YangFeng-Qing Yang
Feng-Qing Yang

17 August 2022 in Chemosensors
Verified
Journal Article
Open access
PDF file
WZWei-Yi Zhang
Wei-Yi Zhang
HZHao Zhang
Hao Zhang
Feng-Qing YangFeng-Qing Yang
Feng-Qing Yang
In this study, a paper-based sensor was developed for the detection of hydrogen-peroxide-related biomarkers, with glucose oxidase catalyzing as an example. Potassium iodide can catalyze the oxidation of 3,3′,5,5′-tetramethylbenzidine in the presence of hydrogen peroxide to colorize the paper-based biosensor detection area, which was imaged by a scanner, and the color intensity was analyzed by the Adobe Photoshop. Under the optimal conditions, the color intensity shows a good linear relationship with hydrogen peroxide and glucose concentrations in the ranges of 0.1–5.0 mM and 0.5–6.0 mM, respectively. The detection limit of hydrogen peroxide is 0.03 mM and the limit of quantification of glucose is 0.5 mM. Besides, the method was employed in measuring glucose concentration in fruit samples, and the spiked recoveries are in the range of 95.4–106.1%. This method is cost-effective, environmentally friendly, and easy to be operated, which is expected to realize the point-of-care testing of more hydrogen-peroxide-related biomarkers.

11 April 2019 in Molecules
Verified
Journal Article
Open access
PDF file
WFWen FeiYan
Wen FeiYan
TCTiezhu Chen
Tiezhu Chen
HYhongxiang Yin
hongxiang Yin
JLJuan Lin
Juan Lin
HZHao Zhang
Hao Zhang
The resource shortage of Rhizoma Paridis has never been effectively addressed, and the industry continues to search for alternative resources. The in vitro effects on thrombin of Paris saponins and in vivo hemostatic activity of Paris fargesii var. brevipetala (PF) were evaluated in this study. PF is considered to be an alternative source of Rhizoma Paridis (RP). The in vitro incubation experiment was designed to investigate the effects on thrombin activity of Paris saponin H (PS H) and saponin extract in PF. The bleeding time of mouse tail snipping was used to evaluate the in vivo hemostatic effects of Paris saponins. Also, in vivo changes in four blood coagulation parameters in rats after oral administration of different groups of Paris saponins were compared. The effects of Paris saponins on liver function and blood lipid parameters were examined in order to avoid drug-induced liver injury. Activity studies of thrombin after ultra-filtration centrifugation showed that Paris saponins were able to enhance thrombin activity. Ultra performance liquid chromatography mass spectrometry (UPLC-MS) analysis results of the substrates led us to speculate that there is a specific binding between Paris saponins and thrombin. PS H and Paris saponins in PF significantly shortened the bleeding time in mice. One pathway by which Paris saponins enhance in vivo blood coagulation is by increasing fibrinogen (FIB), among the four blood coagulation parameters in rats. At the same time, the effects on liver and blood lipid parameters were insignificant. P. fargesii var. brevipetala can be developed as an alternative medicinal source of Rhizoma Paridis.

18 October 2022 in Biosensors
Verified
Journal Article
Open access
PDF file
WZWei-Yi Zhang
Wei-Yi Zhang
TTTao Tian
Tao Tian
LPLi-Jing Peng
Li-Jing Peng
HZHang-Yu Zhou
Hang-Yu Zhou
HZHao Zhang
Hao Zhang
Feng-Qing YangFeng-Qing Yang
Feng-Qing Yang
In this work, indoxyl-glucoside was used as the substrate to develop a cost-effective, paper-based analytical device for the fluorescent and colorimetric dual-mode detection of β-glucosidase activity through a smartphone. The β-glucosidase can hydrolyze the colorless substrate indoxyl-glucoside to release indoxyl, which will be self-oxidized to generate green products in the presence of oxygen. Meanwhile, the green products emit bright blue-green fluorescence under ultraviolet–visible light irradiation at 365 nm. Fluorescent or colorimetric images were obtained by a smartphone, and the red-green-blue channels were analyzed by the Adobe Photoshop to quantify the β-glucosidase activity. Under the optimum conditions, the relative fluorescent and colorimetric signals have a good linear relationship with the activity of β-glucosidase, in the range of 0.01–1.00 U/mL and 0.25–5.00 U/mL, and the limits of detection are 0.005 U/mL and 0.0668 U/mL, respectively. The activities of β-glucosidase in a crude almond sample measured by the fluorescent and colorimetric methods were 23.62 ± 0.53 U/mL and 23.86 ± 0.25 U/mL, respectively. In addition, the spiked recoveries of normal human serum and crude almond samples were between 87.5% and 118.0%. In short, the paper-based device, combined with a smartphone, can provide a simple, environmentally friendly, and low-cost method for the fluorescent and colorimetric dual-mode detection of β-glucosidase activity.

1 August 2021 in Science of The Total Environment
Verified
Journal Article
Open access
JRJosé Germán Rodríguez
José Germán Rodríguez
IAIsabelle Amouroux
Isabelle Amouroux
MBMaría Jesús Belzunce-Segarra
María Jesús Belzunce-Segarra
PBPhilippe Bersuder
Philippe Bersuder
TBThi Bolam
Thi Bolam
HZHao Zhang
Hao Zhang
The current study evaluates the effect of seawater physico-chemical characteristics on the relationship between the concentration of metals measured by Diffusive Gradients in Thin films (DGT) passive samplers (i.e., DGT-labile concentration) and the concentrations measured in discrete water samples. Accordingly, Inductively Coupled Plasma Mass Spectrometry (ICP-MS) was used to measure the total dissolved metal concentrations in the discrete water samples and the labile metal concentrations obtained by DGT samplers; additionally, lead and cadmium conditional labile fractions were determined by Anodic Stripping Voltammetry (ASV) and total dissolved nickel was measured by Cathodic Stripping Voltammetry (CSV). It can be concluded that, in general, the median ratios of DGT/ICP and DGT/ASV(CSV) were lower than 1, except for Ni (median ratio close to 1) and Zn (higher than 1). This indicates the importance of speciation and time-integrated concentrations measured using passive sampling techniques, which is in line with the WFD suggestions for improving the chemical assessment of waterbodies. It is the variability in metal content in waters rather than environmental conditions to which the variability of the ratios can be attributed. The ratios were not significantly affected by the temperature, salinity, pH, oxygen, DOC or SPM, giving a great confidence for all the techniques used. Within a regulatory context such as the EU Water Framework Directive this is a great advantage, since the simplicity of not needing to use corrections to minimize the effects of environmental variables could help in implementing DGTs within monitoring networks.