This paper presents a new approach to wearable hand gesture recognition and finger angle estimation based on modified barometric pressure sensing. Barometric pressure sensors were encased and injected with VytaFlex rubber such that the rubber directly contacted the sensing element allowing pressure change detection when the encasing rubber was pressed. A wearable prototype consisting of an array of 10 modified barometric pressure sensors around the wrist was developed and validated with experimental testing for three different hand gesture sets and finger flexion/extension trials for each of the five fingers. Overall hand gesture recognition classification accuracy was 94%. Further analysis revealed that the most important sensor location was the underside of the wrist and that when reducing the sensor number to only 5 optimally placed sensors, classification accuracy was still 90%. For continuous finger angle estimation, aggregate R2 values between actual and predicted angles were thumb: 0.81±0.10, index finger: 0.85±0.06, middle finger: 0.77±0.08, ring finger: 0.77±0.12, and pinkie finger: 0.75±0.10, and the overall average was 0.79±0.05. These results demonstrate that a modified barometric pressure wristband can be used to classify hand gestures and to estimate individual finger joint angles. This approach could serve to improve clinical treatment for upper extremity deficiencies, such as for stroke rehabilitation, by providing objective patient motor control metrics to inform and aid physicians and therapists throughout the rehabilitation process.
Hand gestures are expressive motions that convey meaningful information. The ability for machines to extract and process the underlying meanings of these gestures is critical to many human-interactive applications. Various methods have been proposed, but the development of a more accurate, and simpler system could enable the machine and its user to exchange useful information more effectively. In this paper, a barometric-pressure-sensor-based wristband is presented as an initial proof of such concept. The wristband is composed of an array of 10 barometric pressure sensors spaced evenly around the wrist to estimate pressure profiles as tendons and muscles change with various hand gestures. Subject testing was performed to quantify classification accuracy for three groups of hand gestures: group 1) six wrist gestures, group 2) five single finger flexions, and group 3) ten Chinese number gestures. Leave-one-out cross-validation was used to compute classification accuracy. Results demonstrated classification accuracies of 98% for the wrist gestures, 95% for the single finger flexions, and 90% for Chinese number gestures. The presented pressure sensing wristband could potentially be used for a variety of applications including gesture-controlled devices, health-monitoring devices, and assistive devices for deaf-mute individuals.
Despite showing promising functional outcomes for pelvic reconstruction after sarcoma resection, custom-made pelvic implants continue to exhibit high complication rates due to fixation failures. Patient-specific finite element models have been utilized by researchers to evaluate implant durability. However, the effect of assumed boundary and loading conditions on failure analysis results of fixation screws remains unknown. In this study, the postoperative stress distributions in the fixation screws of a state-of-the-art custom-made pelvic implant were simulated, and the risk of failure was estimated under various combinations of two bone-implant interaction models (tied vs. frictional contact) and four load cases from level-ground walking and stair activities. The study found that the average weighted peak von Mises stress could increase by 22-fold when the bone-implant interactions were modeled with a frictional contact model instead of a tied model, and the likelihood of fatigue and pullout failure for each screw could change dramatically when different combinations of boundary and loading conditions were used. The inclusion of additional boundary and loading conditions led to a more reliable analysis of fixation durability. These findings demonstrated the importance of simulating multiple boundary conditions and load cases for comprehensive implant design evaluation using finite element analysis.
Aims: Internal hemipelvectomy without reconstruction of the pelvis is a viable treatment for pelvic sarcoma; however, the time it takes to return to excellent function is quite variable. Some patients require greater time and rehabilitation than others. To determine if psoas muscle recovery is associated with changes in ambulatory function, we retrospectively evaluated psoas muscle size and limb-length discrepancy (LLD) before and after treatment and their correlation with objective functional outcomes.Methods: T1-weighted MR images were evaluated at three intervals for 12 pelvic sarcoma patients following interval hemipelvectomy without reconstruction. Correlations between the measured changes and improvements in Timed Up and Go test (TUG) and gait speed outcomes were assessed both independently and using a stepwise multivariate regression model.Results: Increased ipsilesional psoas muscle size from three months postoperatively to latest follow-up was positively correlated with gait speed improvement (r = 0.66). LLD at three months postoperatively was negatively correlated with both TUG (r = -0.71) and gait speed (r = -0.61).Conclusion: This study suggests that psoas muscle strengthening and minimizing initial LLD will achieve the greatest improvements in ambulatory function. LLD and change in hip musculature remain substantial prognostic factors for achieving the best clinical outcomes after internal hemipelvectomy. Changes in psoas size were correlated with the amount of functional improvement. Several patients in this study did not return to their preoperative ipsilateral psoas size, indicating that monitoring changes in psoas size could be a beneficial rehabilitation strategy.Cite this article: Bone Joint J 2023;105-B(3):323–330.
Custom implants used for pelvic reconstruction in pelvic sarcoma surgery face a high complication rate due to mechanical failures of fixation screws. Consequently, patient-specific finite element (FE) models have been employed to analyze custom pelvic implant durability. However, muscle forces have often been omitted from FE studies of the post-operative pelvis with a custom implant, despite the lack of evidence that this omission has minimal impact on predicted bone, implant, and fixation screw stress distributions. This study investigated the influence of muscle forces on FE predictions of fixation screw pullout and fatigue failure in a custom pelvic implant. Specifically, FE analyses were conducted using a patient-specific FE model loaded with seven sets of personalized muscle and hip joint contact force loading conditions estimated using a personalized neuromusculoskeletal (NMS) model. Predictions of fixation screw pullout and fatigue failure—quantified by simulated screw axial forces and von Mises stresses, respectively—were compared between analyses with and without personalized muscle forces. The study found that muscle forces had a considerable influence on predicted screw pullout but not fatigue failure. However, it remains unclear whether including or excluding muscle forces would yield more conservative predictions of screw failures. Furthermore, while the effect of muscle forces on predicted screw failures was location-dependent for cortical screws, no clear location dependency was observed for cancellous screws. These findings support the combined use of patient-specific FE and NMS models, including loading from muscle forces, when predicting screw pullout but not fatigue failure in custom pelvic implants.