Amirhossein Borjali

Mr. Amirhossein Borjali

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 January 2022 in Sensors
Verified
Journal Article
Open access
PDF file
Mohsen ForouzanmehrMohsen Forouzanmehr
Mohsen Forouzanmehr
Kazem Reza KashyzadehKazem Reza Kashyzadeh
Kazem Reza Kashyzadeh
ABAmirhossein Borjali
Amirhossein Borjali
AIAnastas Ivanov
Anastas Ivanov
MJMosayeb Jafarnode
Mosayeb Jafarnode
Mahmoud ChizariMahmoud Chizari
Mahmoud Chizari
Bipolar Plates (BPPs) are the most crucial component of the Polymer Electrolyte Membrane (PEM) fuel cell system. To improve fuel cell stack performance and lifetime, corrosion resistance and Interfacial Contact Resistance (ICR) enhancement are two essential factors for metallic BPPs. One of the most effective methods to achieve this purpose is adding a thin solid film of conductive coating on the surfaces of these plates. In the present study, 410 Stainless Steel (SS) was selected as a metallic bipolar plate. The coating process was performed using titanium nitride and chromium nitride by the Cathodic Arc Evaporation (CAE) method. The main focus of this study was to select the best coating among CrN and TiN on the proposed alloy as a substrate of PEM fuel cells through the comparison technique with simultaneous consideration of corrosion resistance and ICR value. After verifying the TiN and CrN coating compound, the electrochemical assessment was conducted by the potentiodynamic polarization (PDP) and electrochemical impedance spectroscopy (EIS) tests. The results of PDP show that all coated samples have an increase in the polarization resistance (Rp) values (ranging from 410.2 to 690.6 Ω·cm2) compared to substrate 410 SS (230.1 Ω·cm2). Corrosion rate values for bare 410 SS, CrN, and TiN coatings were measured as 0.096, 0.032, and 0.060 mpy, respectively. Facilities for X-ray Diffraction (XRD), Scanning Electron Microscope (FE-SEM, TeScan-Mira III model and made in the Czech Republic), and Energy Dispersive X-ray Spectroscopy (EDXS) were utilized to perform phase, corrosion behavior, and microstructure analysis. Furthermore, ICR tests were performed on both coated and uncoated specimens. However, the ICR of the coated samples increased slightly compared to uncoated samples. Finally, according to corrosion performance results and ICR values, it can be concluded that the CrN layer is a suitable choice for deposition on 410 SS with the aim of being used in a BPP fuel cell system.

4 September 2020 in bioRxiv
Verified
Preprint
Open access
PDF file
ABAmirhossein Borjali
Amirhossein Borjali
MMMahdi Mohseni
Mahdi Mohseni
Mahmoud ChizariMahmoud Chizari
Mahmoud Chizari
Background: Bone tunnel enlargement is considered as a potential problem following ACL reconstruction and can cause a fixation failure and complicate its revision surgery. This study evaluates post tibial tunnel expansion in ACL reconstruction using an interference screw. Methods: A series of in-vitro experimental tests on animal bone and tissues were used to simulate post ACL reconstruction. The study believes an unbalanced lateral force can cause a local enlargement on the contact zone inside the tunnel. Grayscale X-ray images were used to assess the screw alignment inside the tunnel. Results: They showed a slight misalignment between the screw and the tunnel axis as the tendon strands moved along the side of the tunnel, and the screw had partial contact with the tendon and bone along the tunnel. According to the results, increased stress in the tunnel wall causes tunnel enlargement. Although the tunnel created away from the tibial central axis produced a higher strength, it results in higher stress on the wall of the tunnel which can increase the risk of tunnel expansion. Conclusions: The current study believes the use of an unguided interference screw insertion potentially increases risks of the misaligned fixation and cause a tunnel enlargement. This risk may be controlled by restricting the post-operative rehabilitation.

13 July 2021 in bioRxiv
Verified
Preprint
Open access
PDF file
MMMahdi Mohseni
Mahdi Mohseni
ANAmir Nourani
Amir Nourani
HKHossein Korani
Hossein Korani
HMHadi Moeinnia
Hadi Moeinnia
ABAmirhossein Borjali
Amirhossein Borjali
Mahmoud ChizariMahmoud Chizari
Mahmoud Chizari
Background: Bone and site hold tendon inside (BASHTI) is an implant-less technique that can solve some of the problems associated with other anterior cruciate ligament (ACL) reconstructive methods. This study aims to investigate the effect of core bone diameter variation on the biomechanical properties of a reconstructed ACL using BASHTI technique. Methods: A number of 15 laboratory samples of reconstructed ACL were built using bovine digital tendons and Sawbones blocks. Samples were divided into three groups with different core bone diameters of 8 mm, 8.5 mm, and 9 mm. The double-stranded tendon size and bone tunnel diameter were 8 mm and 10 mm, respectively. A loading scenario consisting of two cyclic loadings followed by a single cycle pull-out loading was applied to the samples simulating the after-surgery loading conditions to observe the fixation strength. Results: Results showed that the core bone diameter had a significant effect on the failure mode of the samples ( P = 0.006) and their fixation strength ( P < 0.001). Also, it was observed that the engaging length and the average cyclic stiffness (ACS) of them were influenced by the core bone diameter significantly (engaging length: P = 0.001, ACS: P = 0.007), but its effect on the average pull-out stiffness was not significant ( P = 0.053). Conclusions: It was concluded that core bone diameter variation has a significant impact on the mechanical properties of ACL reconstruction when BASHTI technique is used, and it should be noted for surgeons who use BASHTI technique. Abstract Figure: Highlights: A new implant-less technique was used to reconstruct anterior cruciate ligament. Artificial bone and fresh animal soft tissue used to simulate the fixation process. Loading condition were carefully chosen to simulate the post-operation. Components geometry had direct effect on biomechanical properties of the fixation. Optimum geometry was found trough an experimental examination.

11 February 2023 in Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
Verified
Journal Article
Open access
ABAmirhossein Borjali
Amirhossein Borjali
GFGholamHossein Farrahi
GholamHossein Farrahi
Mahmoud ChizariMahmoud Chizari
Mahmoud Chizari
Bone and Site Hold Tendon Inside (BASHTI) technique is an implant-less surgical methodology used for anterior cruciate ligament (ACL) reconstruction. It has some clinical advantages, such as speeding up the healing process. Since the force required to insert the core bone inside the tunnel may damage the core bone and affect the fixation process, the study aims to investigate the strength of fixation of BASHTI technique using proposed sheathed core bones. Experimental tests were performed to evaluate the biomechanical strength of the fixation. Synthetic bone combined with bovine tendons as a graft was used. Polymers were used to create the sheath for mechanical testing. The results showed that fixation strength and stiffness in PTFE sheath with 0.1 mm were 343.86 N and 114.62 N/mm and in PVC sheath with similar thickness, 235.95 N, and 93.36 N/mm. Subsequently, 0.2 mm PTFE sheaths were tested in two different sections: incomplete fixation and complete fixation. The strength and stiffness of the first section were 221.6 N and 66.99 N/mm and for the second section 420.02 N and 126.16 N/mm. Using sheath facilitates the fixation process in BASHTI technique. The 0.1 mm PTFE sheath and 0.2 mm PTFE sheath with complete fixation provide higher fixation strength than other groups. The outcome showed that engaged length has a direct effect on the fixation strength. The BASHTI technique offers an implant-less organic ACL reconstruction method that can improve the fixation method and speed up the healing process.

23 September 2020 in medRxiv
Verified
Preprint
Open access
PDF file
FBFarid Behzadian
Farid Behzadian
ABAmirhossein Borjali
Amirhossein Borjali
Mahmoud ChizariMahmoud Chizari
Mahmoud Chizari
Many people may suffer from missing a tooth or teeth for different reasons. Dental implants are one of the primary solutions which are being used increasingly in the last few decades. In the first stage of the usual procedure, the surgeon uses a drill to create a socket into the jaw bone; then, in the next step, the implant, which is a fine metal screw most of the time, will be inserted into the pre-drilled socket. This study investigates the biomechanical behaviors of a new dental implant which has a different performance and thread design. The strength of the new implant has been assessed under a daily loading through a series of experimental tests using dummy foam block substitute to the natural human jawbone. The feature of the new design was modified to introduce a new dental implant for brittle jawbones. The study was closely focusing on the design criteria of the implant applicable for D3-D4 zones of the jaw bone.