Izabela Gabryelczak

Dr. Izabela Gabryelczak


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 January 2022 in Materials
Verified
Journal Article
Open access
PDF file
Marcin KozakiewiczMarcin Kozakiewicz
Marcin Kozakiewicz
IGIzabela Gabryelczak
Izabela Gabryelczak
BBBartosz Bielecki-Kowalski
Bartosz Bielecki-Kowalski
Titanium alloys are used in skeletal surgery. However, once bone union is complete, such fixation material becomes unnecessary or even harmful. Resorbable magnesium materials have been available for several years (WE43 alloy). The aim of this study was to clinically compare magnesium versus titanium open reduction and rigid fixations in mandible condylar heads. Ten patients were treated for fractures of the mandibular head with magnesium headless compression screws (2.3 mm in diameter), and 11 patients were included as a reference group with titanium screws (1.8 mm in diameter) with similar construction. The fixation characteristics (delay, time, and number of screws), distant anatomical results (mandibular ramus height loss, monthly loss rate, and relative loss of reconstructed ramus height), basic functional data (mandibular movements, facial nerve function, and cutaneous perception) and the influence of the effects of the injury (fracture type, fragmentation, occlusion, additional fractures, and associated diseases) on the outcome were evaluated. The long-term results of treatment were evaluated after 18 months. Treatment results similar to those of traditional titanium fixation were found with magnesium screws. Conclusions: Resorbable metal screws can be a favored option for osteosynthesis because surgical reentry can be avoided. These materials provide proper and stable treatment results.

17 March 2022 in Materials
Verified
Journal Article
Open access
PDF file
Marcin KozakiewiczMarcin Kozakiewicz
Marcin Kozakiewicz
IGIzabela Gabryelczak
Izabela Gabryelczak
For some years now, fixation devices created with resorbable magnesium alloys for the mandibular head have been clinically available and are beginning to be used. It is thus valuable to evaluate the quality of unions in these cases. The aim of this study was radiological comparison of magnesium versus titanium open reduction and rigid fixations in the mandible condylar head. Thirty-one patients were treated for fractures of the mandibular head with magnesium WE43 alloy headless compression screws (diameter 2.3 mm) and, as a reference group, 29 patients were included with similar construction titanium screws (diameter 1.8 mm). The 12-month results of the treatment were evaluated by the texture analysis of CT. Near similar treatment results were found with magnesium screws in traditional titanium fixation. Magnesium screws result in a higher density of the bone structure in the mandibular head. Conclusions: The quantitative evaluation of bone union after surgical treatment of mandibular head fracture with magnesium compression headless screws indicates that stable consolidation was achieved. Undoubtedly, the resorption process of the screws was found to be incomplete after 12 months, evidenced by a marked densification of the bone structure at the fracture site.

Verified
Journal Article
Open access
PDF file
KGKacper Galant
Kacper Galant
MKMarcin Kozakiewicz
Marcin Kozakiewicz
ACAgata Izabela Ciosek
Agata Izabela Ciosek
KBKatarzyna Bogusiak
Katarzyna Bogusiak
IGIzabela Gabryelczak
Izabela Gabryelczak
Background/Objectives: Orbital fractures are a very serious problem due to the close location of the eyeball and a direct path to brain injuries, which is associated with serious consequences. This study aims to assess the usefulness of the Orbital Destruction Intensity (ODI) scale. Additionally, this article includes elements of an epidemiological study. Methods: A retrospective study of 160 patients admitted to the Department of Maxillofacial Surgery in Łódź (Poland) between January 2021 and June 2024 was conducted. In this study, general patient information (gender, age), details about the injuries (cause, affected orbit, accompanying symptoms), diagnosis (ODI scale, pathological classification), and treatment were assessed. Analysis of the distribution of features and regression analysis was performed in the case of quantitative data. To compare the assessment of the impact of a categorical variable on a quantitative variable, the Kruskal–Wallis test was used. A p-value of less than 0.05 was considered statistically significant. Results: The main cause of the accident was assault, which accounted for 39% of cases. An X-ray examination showed that patients had an average ODI score of 2.92 ± 1.69. Patients with low ODI scores mostly had isolated fractures of the orbital floor. As ODI scores increased, zygomaticomaxillary complex (ZMCO) fractures became more common as an additional fracture (p < 0.05). For patients with low ODI scores, treatment generally involves reconstructing the orbital wall with titanium mesh. For those with higher ODI scores, treatment may include microplate osteosynthesis or a combination of both methods (p < 0.05). Conclusions: A correlation was observed between the diagnosis based on ODI, anatomical classification, and the treatment provided. This relationship is related to the nature of the ODI scale, as, when the severity of the injury increases, additional anatomical structures (walls or rims of the orbit) are included.

21 May 2025 in Preprints.org
Verified
Preprint
Open access
PDF file
IGIzabela Gabryelczak
Izabela Gabryelczak
Marcin KozakiewiczMarcin Kozakiewicz
Marcin Kozakiewicz
Objectives: Against common belief, mandibular condyle fractures are not that rare, with morbidity rates ranging from 19 to 52%, depending on actual literature sources. Practitioners try to improve the surgical techniques applied to obtain the most satisfactory anatomical and functional effect. The purpose of this study is to identify the relationships that af-fect bone loss around screws and plates in mandibular condylar process fractures treated surgically using the Open Reduction and Internal Fixation (ORIF) technique. Materials and Methods Our research covered 276 fractures of the base, low and high neck of the condylar pro-cess. Based on CT scans, we studied various parameters, including bone healing in the fracture area, bone loss in the screws and plates area, change in the length of the man-dibular ramus following osteosynthesis and on the opposite side after 12 months, as well as deformities of the mandibular head. Results Using screws and plates is the gold standard for treating mandibular condylar process fractures. The number of screws used affects the bone loss ratio around head of the screw. Another factor that impacts the results achieved is the distance from the plate edge to the lateral pole of the mandibular head. Statistical evaluation indicated that proximity to the lateral pole is a risk factor for bone resorption at the plate edge. Conclusion Based on the collected data, it is possible to predict bone loss, determine the location and selection of plates and screws, as well as to plan the procedure, achieving the low-est possible loss rates.