This paper aims to disclose the noticeable effect of local tangential force on vibration performance in fractional-slot concentrated-winding permanent magnet synchronous machines (PMSMs). The mechanism to induce vibrations by tangential force is revealed at first. It is found tangential force is able to deflect the yoke through the tooth's lever arm effect. This phenomenon is detailedly explained through finite element simulation and analytical description of the microscopic deformation in the paper. With the aid of a 10-pole/12-slot PMSM, the quantitative contribution of tangential force to the vibration is also investigated through simulation, vibration synthesis and experiments. Results show that due to the strong lever arm effect and not so small force amplitudes as commonly expected, the contribution of tangential force to final vibration is comparable to that of radial force. Besides that, the synthesized vibrations indicate the contribution of tangential force decreases with the increase of non-zero spatial order, in a way similar to radial force. In order to underpin the findings, more situations such as with different pole-slot combinations are also analyzed at last.
This paper investigates the vibration enhancement or weakening effect caused by permanent magnet synchronous motor radial and tangential force formed by tooth harmonics. First, the analytical expressions of an air gap magnetic field are deduced based on a permanent magnet synchronous motor model. Then, the Maxwell stress tensor method is employed to calculate the radial and tangential force density produced by permanent magnet magnetomotive force harmonics and tooth harmonics. Moreover, the spatial phase difference between the minimum non-zero spatial order radial and tangential force waves under loading operation are also obtained. It is followed by stator vibration deformation induced by radial and tangential force waves, and the vibration enhancement or weakening effect is discussed. This study shows that the tangential force wave has a significant influence on the vibration performance similar to the radial force wave. At specific frequencies, superposition of the radial and tangential force waves can intensify the vibration while weakening each other to reduce the vibration at other specific frequencies. Numerical simulation and a vibration measurement experiment of the prototype motor were carried out to confirm the proposed theory, which can guide motor designers in selecting an appropriate pole and slot combination to apply the weakening effect between radial and tangential force waves and improve PMSM vibration performance.
10 September 2024 in IEEE Transactions on Applied Superconductivity
This paper analyzes the vibration contribution of radial and tangential electromagnetic force harmonic of permanent magnet synchronous motor. Firstly, infer the analytical expressions of the air gap magnetic field generated by permanent magnet and armature reaction. Then, the radial and tangential electromagnetic force density produced by different sources are obtained with Maxwell stress theory. After that, the modal shapes and frequencies of the prototype are studied by means of finite element analysis and experimental modal testing. At last, the vibration contribution of radial and tangential electromagnetic force harmonic of the prototype is analyzed quantitatively by harmonic response simulation and experiment. The research demonstrates that in the motor design stage, if the vibration performance is the primary characteristic to be concerned, the contribution of the tangential force needs to be taken seriously.
12 August 2024 in IEEE Transactions on Applied Superconductivity
The permanent magnet synchronous motor (PMSM) has some shortcomings such as poor overload capacity and large vibration. In this paper, a special shaped pole piece motor is presented. According to the principle of magnetic field energy, the special-shaped pole piece (SSPP) increases the equivalent length of the air gap, and deduces the theoretical basis for the reduction of magnetic density and slot torque of the motor. The finite element model was established to analyze the no-load, rated load and overload conditions of the motor. The concentrated force of the teeth and vibration at each frequency were solved. The results show that the method can reduce the saturation degree of the motor, improve the overload capacity and efficiency, and weaken the low frequency vibration, so it has a significant application value.
13 May 2025 in IEEE Transactions on Transportation Electrification
Open-circuit fault, as a common type of winding faults, can lead to severe vibration in permanent magnet synchronous motors. However, the reason of this phenomenon is not well understood yet. Hence, this article proposes a similarity measure method for suppressing vibration of the four-unit permanent magnet synchronous motor under the open-circuit fault operation. Firstly, the shortcoming of the traditional fault tolerance method is studied, and the analysis indicates that the electromagnetic forces and moment are distributed asymmetrically along the air gap circumference. Then, it is found that the vibration intensification is induced by the asymmetric armature reaction magnetic field. By the proposed similarity measure method, the fault tolerance currents are derived and the armature reaction magnetic field is redesigned. The results show that the vibration performance is greatly improved by applying the proposed fault tolerance method. Finally, the prototype of an 8pole-12slot four-unit permanent magnet synchronous motor is manufactured. Several numerical simulations and prototype experiments are carried out to verify the effectiveness of the proposed fault tolerance method.
12 August 2024 in IEEE Transactions on Applied Superconductivity
The vibration mode number (VMN) is the crucial parameter for the electromagnetic vibration in the permanent magnet synchronous machine (PMSM). This paper proposed a method using the equivalent concentrated force (ECF) and the equivalent concentrated moment (ECM) to calculate the VMN. First, the ECF and the ECM were analyzed based on the force-transformation model. Because the VMN is equal to the spatial cycle number (SCN) of the ECF or ECM harmonics over the entire machine, the SCN calculation of the ECF or ECM harmonics was proposed. Then, a 10-pole/12-slot PMSM was used to compare VMNs obtained by the proposed method and FEM. It was demonstrated that the calculated result generally agreed with the simulated result. Finally, the proposed method was validated by measuring the vibration of the 10-pole/12-slot PMSM. The results proved that the proposed method can calculate the VMN.