Zhonghe Xu

Zhonghe Xu

Auto-generated profile, based on publicly available information

Zhonghe Xu

School of Electrical Engineering, Harbin Institute of Technology, Harbin, China

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 March 2022 in IEEE Transactions on Magnetics
Verified
Journal Article
Closed access
ZXZhonghe Xu
Zhonghe Xu
Guodong YuGuodong Yu
Guodong Yu
Yongxiang XuYongxiang Xu
Yongxiang Xu
JZJibin Zou
Jibin Zou
Zeroth-mode vibration is the dominant noise source in permanent magnet synchronous machines (PMSMs). In conventional approaches, the zeroth-mode vibration is reduced by lowering the amplitudes of concentrated forces. Different from conventional approaches, this article proposes a zeroth-mode vibration suppression method through adjustment on phase difference of concentrated forces. First, the characteristics of concentrated forces are analyzed considering the effect of slotted structure on air-gap electromagnetic force wave (EMFW), and the relationship between phase difference of concentrated force harmonics (CFHs) and the mode of vibration is obtained. Subsequently, the effects of both permanent magnet (PM) and harmonic currents on air-gap EMFW are analyzed. It is found that the phase differences of CFHs can be adjusted by combining PM shape optimization and harmonic current injection. Finally, a 12-pole 36-slot PMSM and a 16-pole 48-slot PMSM are carried out to calculate the concentrated forces and vibrations by finite element method (FEM). It is proven that the proposed method can adjust the phase difference from zero to two tooth pitches, and the zeroth-mode vibration is significantly suppressed.

6 March 2024 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
Yongxiang XuYongxiang Xu
Yongxiang Xu
ZXZhonghe Xu
Zhonghe Xu
JZJibin Zou
Jibin Zou
Guodong YuGuodong Yu
Guodong Yu
Zeroth-mode vibration is the important noise source in most permanent magnet synchronous machines (PMSMs). In this article, the electromagnetic force and the vibration were studied along different directions, and a new method was proposed to suppress the zeroth-mode vibration for surface-mounted PMSMs (SPMSMs). First, it was found that the vibration response is almost inversely proportional to the fourth power of the axial spatial order of the electromagnetic force harmonic by studying the electromagnetic force and the vibration along different directions. Based on the relationship, a new method is proposed to increase the axial spatial order of the electromagnetic force harmonic for the zeroth-mode vibration suppression. Next, the effect of the proposed method is validated by simulating the electromagnetic performances and the vibrations of three 10-pole/30-slot SPMSMs, whose rotors are designed using different methods. Finally, three prototypes are built to compare the vibration accelerations, and the results prove that the proposed method can suppress the zeroth-mode vibration effectively.

16 July 2024 in IEEE Transactions on Transportation Electrification
Verified
Journal Article
Closed access
Yongxiang XuYongxiang Xu
Yongxiang Xu
ZXZhonghe Xu
Zhonghe Xu
JZJibin Zou
Jibin Zou
Guodong YuGuodong Yu
Guodong Yu
Zeroth-mode vibration is the main electromagnetic (EM) vibration component in integral-slot permanent magnet synchronous machines (PMSMs). This paper proposes a new method for integral-slot surface-mounted PMSMs to suppress the zeroth-mode vibration by increasing the vibration mode from zero to the pole pair number. The proposed method involves designing two different permanent magnet (PM) shapes, respectively, for the N and S poles to make the specified EM force harmonics under adjacent poles equal in amplitude and opposite in phase. In this paper, the EM vibration was analyzed based on the modulation effect of the slotted structure and the theorem of translation of a force. The relationship between the vibration mode and the EM force harmonics has been summed up. Based on this, the proposed method was expounded, and a 10-pole/30-slot surface-mounted PMSM was taken as an instance to demonstrate the process of the proposed method. Three prototypes with different rotors were simulated and measured to validate the proposed method. The results have proved the effectiveness of the proposed method.

28 June 2024 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
XZXiaofeng Zhang
Xiaofeng Zhang
Yongxiang XuYongxiang Xu
Yongxiang Xu
JZJibin Zou
Jibin Zou
ZXZhonghe Xu
Zhonghe Xu
For the annular permanent magnet synchronous motor (APMSM), a novel strategy for driving multi-passive carriers is innovatively proposed in this article. The strategy abandons the concept of “phase” in motor control, adopts a single coil as the basic control unit, and independently controls the currents of the coils coupled with the carrier. This strategy can realize a single stator driving multiple carriers, effectively reducing the spacing of carriers and lowering the system's copper loss. An experimental platform based on a field-programmable gate array (FPGA) and a digital signal processor (DSP) is built to verify the effectiveness of the proposed strategy.

13 May 2025 in IEEE Transactions on Transportation Electrification
Verified
Journal Article
Closed access
MLMingchuan Liu
Mingchuan Liu
JZJibin Zou
Jibin Zou
BZBoyuan Zheng
Boyuan Zheng
ZXZhonghe Xu
Zhonghe Xu
Yongxiang XuYongxiang Xu
Yongxiang Xu
Open-circuit fault, as a common type of winding faults, can lead to severe vibration in permanent magnet synchronous motors. However, the reason of this phenomenon is not well understood yet. Hence, this article proposes a similarity measure method for suppressing vibration of the four-unit permanent magnet synchronous motor under the open-circuit fault operation. Firstly, the shortcoming of the traditional fault tolerance method is studied, and the analysis indicates that the electromagnetic forces and moment are distributed asymmetrically along the air gap circumference. Then, it is found that the vibration intensification is induced by the asymmetric armature reaction magnetic field. By the proposed similarity measure method, the fault tolerance currents are derived and the armature reaction magnetic field is redesigned. The results show that the vibration performance is greatly improved by applying the proposed fault tolerance method. Finally, the prototype of an 8pole-12slot four-unit permanent magnet synchronous motor is manufactured. Several numerical simulations and prototype experiments are carried out to verify the effectiveness of the proposed fault tolerance method.

12 August 2024 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
ZXZhonghe Xu
Zhonghe Xu
Yongxiang XuYongxiang Xu
Yongxiang Xu
MLMingchuan Liu
Mingchuan Liu
RZRupeng Zhao
Rupeng Zhao
The vibration mode number (VMN) is the crucial parameter for the electromagnetic vibration in the permanent magnet synchronous machine (PMSM). This paper proposed a method using the equivalent concentrated force (ECF) and the equivalent concentrated moment (ECM) to calculate the VMN. First, the ECF and the ECM were analyzed based on the force-transformation model. Because the VMN is equal to the spatial cycle number (SCN) of the ECF or ECM harmonics over the entire machine, the SCN calculation of the ECF or ECM harmonics was proposed. Then, a 10-pole/12-slot PMSM was used to compare VMNs obtained by the proposed method and FEM. It was demonstrated that the calculated result generally agreed with the simulated result. Finally, the proposed method was validated by measuring the vibration of the 10-pole/12-slot PMSM. The results proved that the proposed method can calculate the VMN.