Geng Wang

Dr. Geng Wang

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 September 2021 in Frontiers in Medicine
Verified
Journal Article
Open access
ZXZixuan Xiao
Zixuan Xiao
GWGeng Wang
Geng Wang
MZMiaoru Zhen
Miaoru Zhen
ZZZifeng Zhao
Zifeng Zhao
Purpose: To investigate the stability of intraocular lens (IOLs) with different haptics by swept-source anterior-segment optical coherence tomography (AS-OCT).Methods: Sixty-eight eyes from 55 patients received the implantation of Rayner 920H (Closed C-loop Group), Zeiss 509M (Plate Group) or Lenstec SOFTEC HD (C-loop Group) IOLs. The tilt and decentration of IOLs were evaluated using AS-OCT at least 1 month postoperatively.Results: Mean decentration and tilt of IOLs were 0.18 ± 0.12 mm (range 0.02 to 0.59 mm) and 5.63 ± 1.65° (range 2.2 to 9.6°) respectively. Decentration was significantly smaller in the plate haptic group (0.12 ± 0.06 mm) as compared to the C-loop group (0.22 ± 0.13 mm, P = 0.02). The tilt of IOL was also significantly smaller in the plate haptic group (4.96 ± 0.89°) as compared to the C-loop group (6.28 ± 1.83°, P = 0.01). There was marginal difference between the Closed C-loop group (5.52 ± 1.74°) and C-loop group (6.28 ± 1.83°, P = 0.07).Conclusions: The Plate-haptic IOLs should have better stability for the decentration and tilt than the C-loop design IOLs.

4 January 2022 in Frontiers in Medicine
Verified
Journal Article
Open access
WGWeifen Gong
Weifen Gong
HCHaoyu Chen
Haoyu Chen
FYFan Yang
Fan Yang
SLShibin Lin
Shibin Lin
CLChao Li
Chao Li
GWGeng Wang
Geng Wang
Purpose: To evaluate the ocular biometric parameters in patients with constant and intermittent exotropia by the measurement of swept-source optical coherence tomography (SS-OCT) optical biometer OA-2000 and comparing it with the normal control subjects.Design: Cross-sectional case-control study.Participants: Fifty-five constant and 24 intermittent patients with exotropia with central fixation and 77 orthotropic normal control participants aged 4–18 years old.Methods: Non-contact and high-resolution optical biometric OA-2000 measurements were conducted under uniform ambient light conditions. The statistical analysis included intraclass correlation coefficient (ICC), Bland-Altman plot, and independent t-tests.Main Outcome Measures: Spherical equivalent (SE), ocular biological parameters such as pupil diameter (PD), anterior chamber depth (ACD), lens thickness (LT), and axial lengths (AL). The absolute values of inter-eye differences for SE, PD, ACD, LT, and AL were recorded as AnisoSE, AnisoPD, AnisoACD, AnisoLT, and AnisoAL, respectively.Results: AnisoSE (0.878 vs. 0.577, P = 0.019), AnisoAL (0.395 vs. 0.208, P = 0.001), AnisoACD (0.060 vs. 0.032, P < 0.001), AnisoLT (0.060 vs. 0.031, P = 0.002), and AnisoPD (0.557 vs. 0.340, P = 0.002) were significantly larger in concomitant patients with exotropia. The SE, AL, ACD, LT, and PD showed excellent binocular correlation with ICC values that ranged from 0.943 to 0.987 in control participants and from 0.767 to 0.955 in concomitant exotropia patients. Bland-Altman plots showed the wider range of agreement in patients with concomitant exotropia than the control participants (SE: 5.0288 vs. 3.3258; AL: 2.2146 vs. 1.3172; ACD:0.3243 vs. 0.1682; PD: 2.4691 vs. 1.9241; and LT:0.3723 vs 0.1858).Conclusion: Patients with concomitant exotropia showed larger inter-eye differences in SE, ACD, LT, PD, and AL. Advice should be given to suspicious children to avoid or delay the development of concomitant exotropia.

1 January 2024 in Journal of Ophthalmology
Verified
Journal Article
Open access
XZXin Zhong
Xin Zhong
YLYan Li
Yan Li
YLYuancun Li
Yuancun Li
GWGeng Wang
Geng Wang
YDYali Du
Yali Du
MZMingzhi Zhang
Mingzhi Zhang
Background. This study aims to investigate the agreement between the NK and KS formulas in predicting the vault after implantation of an EVO‐implantable collamer lens (ICL). Methods. This retrospective study included 106 eyes of 57 patients who underwent ICL‐V4c implantation. Preoperative vault prediction was conducted by utilizing the NK and KS formulas, with postoperative measurements by anterior segment optical coherence tomography (AS‐OCT) at one month. The analysis focused on the consistency between predicted and achieved vaults, as well as the correlation between the achieved vault and various biometric parameters. Results. The mean achieved vault was 605.25 ± 212.72 µm, which was significantly smaller than the predicted vaults of 710.08 ± 195.08 and 673.80 ± 212.76 µm, using the NK and KS formulas, respectively (P < 0.05). The mean differences between the achieved vault and the predicted vault using the NK formula and KS formula were −104.82 μm (95% LoA: −600.38–391.19 μm) and −68.55 μm (95% LoA: −628.91–491.82 μm), respectively. Anterior chamber depth (ACD), vertical sulcus‐to‐sulcus (V‐STS) diameter, and crystalline lens rise (CLR) were independent factors associated with the achieved vault (P < 0.05). The two formulas showed no statistically significant difference in absolute prediction error (APE). Conclusion. The NK formula exhibited superior consistency and low predictive error compared to the KS formula in the 12.6 mm ICL group. AS‐OCT measurements overestimated the predicted ICL vault, especially in the 13.2 mm ICL size selection. Relying solely on the NK or KS formulas for predicting vaults before ICL surgery is not recommended.

25 August 2021 in Frontiers in Medicine
Verified
Journal Article
Open access
GWGeng Wang
Geng Wang
MZMiaoru Zhen
Miaoru Zhen
SLShasha Liu
Shasha Liu
KQKunliang Qiu
Kunliang Qiu
CLCui Liu
Cui Liu
MZMingzhi Zhang
Mingzhi Zhang
Purpose: This study was conducted in order to compare the diagnostic classification of Bruch's membrane opening-minimum rim width (BMO-MRW) and RNFL thickness in normal myopic subjects by using optical coherence tomography (OCT).Methods: This cross-sectional study involved 75 healthy myopic subjects [spherical equivalent (SE) ≤ −0.5D] from April 2019 to January 2020. One eye of each subject was randomly selected for examination. BMO-MRW and peripapillary RNFL thickness were measured by spectral-domain OCT (Spectralis, Heidelberg Engineering GmbH, Heidelberg, Germany). All the subjects were divided into three groups: low myopic group (SE > −3D), moderate myopic group (−6D < SE ≤ −3D), and high myopic group (SE ≤ −6D). A nonparametric test was used to analyze the difference among groups. Linear regression was used to analyze the relationship between BMO-MRW/RNFL thickness and axial length/spherical equivalent. McNemar test was used to compare the diagnostic classification between BMO-MRW and RNFL thickness.Results: The RNFL thickness classified a significantly higher percentage of eyes as outside normal limits/borderline in at least 1 quadrant (BMO-MRW, 4%; RNFL thickness, 34.67%; p < 0.01). There was no significant correlation between BMO-MRW/RNFL thickness and AL/SE. The low myopia (SE > −3D) had a significantly lower percentage of eyes classified as outside normal limits/borderline in at least 1 quadrant than the moderate myopia (−6D < SE ≤ −3D) and high myopia (SE ≤ −6D) (low myopia, 12.5%; moderate/high myopia, 42.42%/50%; p < 0.05).Conclusion: BMO-MRW had a lower percentage of eyes classified as outside normal limits/borderline in at least 1 quadrant than RNFL thickness in normal myopic subjects. When referring to the diagnostic classification of RNFL thickness in myopic subjects, caution should be exercised in interpreting positive results. Further studies are needed to compare the diagnostic accuracy of these two measurements in myopic glaucoma patients.

26 May 2025 in BMJ Open Ophthalmology
Verified
Journal Article
Open access
PDF file
ZWZhengfang Wang
Zhengfang Wang
SZShuang Zhou
Shuang Zhou
YZYeye Zhang
Yeye Zhang
JLJianwei Lin
Jianwei Lin
JLJinyan Lin
Jinyan Lin
GWGeng Wang
Geng Wang
Purpose: To assess the application of generative adversarial networks (GANs) to restore the blurred optical coherence tomography (OCT) images caused by optical media opacity in eyes. Methods: In this cross-sectional study, a spectral-domain OCT (Zeiss Cirrus 5000, Germany) was used to scan the macula of 510 eyes from 272 Chinese subjects. Optical media opacity was simulated with an algorithm for training set (420 normal eyes). Images for three test sets were from the following: 56 normal eyes before and after fitting neutral density filter (NDF), 34 eyes before and after cataract surgeries and 90 eyes processed by algorithm. GANs of pix2pix was trained with training set and restored blurred images in test sets. Structural similarity index (SSIM) and peak signal-to-noise ratio (PSNR) were used to evaluate the performance of GANs. Results: PSNR for test sets before and after image restoration was 18.37±0.44 and 19.94±0.29 for NDF (p<0.01), 16.65±0.99 and 16.91±0.26 for cataract (p=0.68) and 18.33±0.55 and 20.83±0.41 for algorithm regenerated graph (p<0.01), respectively. SSIM for test sets before and after image restoration was 0.85±0.02 and 1.00±0.00 for NDF (p<0.01), 0.92±0.07 and 0.97±0.02 for cataract (p<0.01) and 0.86±0.02 and 0.99±0.01 for algorithm regenerated graph (p<0.01), respectively. Conclusions: GANs can be used to restore blurred OCT images caused by optical media opacity in eyes. Future studies are warranted to optimise this technique before the application in clinical practice.

11 March 2022 in BMC Ophthalmology
Verified
Journal Article
Open access
PDF file
FLFuyao Liu
Fuyao Liu
DLDanting Lin
Danting Lin
CZCe Zheng
Ce Zheng
GWGeng Wang
Geng Wang
Background: To study the iridolenticular contact area (ILCA) under different light conditions in acute primary angle closure (APAC). Methods: This cross-sectional, observational study involved 22 unilateral APAC patients and 59 cataract patients (59 eyes). Images of the APAC eyes, fellow eyes and cataract eyes were collected by anterior segment optical coherence tomography (ASOCT) under different light conditions respectively. The ILCA, anterior chamber width (ACW), anterior chamber area (ACA), lens vault (LV), angle opening distance at 750 μm (AOD750), trabecular iris space area at 750 μm (TISA750) and iris area at 750 μm (IA750) were measured using Image J software. Results: The ILCA of cataract eyes were significantly larger than APAC eyes (4.424 ± 1.208 vs 4.049 ± 2.725mm2, P = 0.034) and fellow eyes (4.424 ± 1.208 vs 3.651 ± 1.629 mm2, P = 0.008) under dark condition. Under dark condition, ILCA of APAC eyes was negatively correlated with AOD750 (r = -0.444, P = 0.038), TISA750 (r = -0.498, P = 0.018). The ILCA of cataract eyes under dark condition was significantly greater than under bright condition (4.424 ± 1.208 vs 2.526 ± 0.992 mm2, P < 0.001). Conclusions: This study showed that ILCA in both APAC eye and fellow eye were smaller than cataract eye. Future study should focus on both the contact area and force at the interface of lens and iris with larger sample size.