Yali Du

Yali Du


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 July 2023 in British Journal of Ophthalmology
Verified
Journal Article
Closed access
PDF file
YLYuancun Li
Yuancun Li
HWHongxi Wang
Hongxi Wang
ZGZhiqiang Guan
Zhiqiang Guan
CGChengyao Guo
Chengyao Guo
PGPi Guo
Pi Guo
MZMingzhi Zhang
Mingzhi Zhang
Aims To assess the global burden and economic inequalities in the distribution of blindness and vision loss between 1990 and 2019. Methods A secondary analysis of the Global Burden of Diseases, Injuries and Risk Factors Study (GBD) 2019. Data for disability-adjusted life-years (DALYs) due to blindness and vision loss were extracted from the GBD 2019. Data for gross domestic product per capita were extracted from the World Bank database. Slope index of inequality (SII) and concentration index were computed to assess absolute and relative cross-national health inequality, respectively. Results Countries with high, high-middle, middle, low-middle and low Socio-demographic Index (SDI) had decline of age-standardised DALY rate of 4.3%, 5.2%, 16.0%, 21.4% and 11.30% from 1990 to 2019, respectively. The poorest 50% of world citizens bore 59.0% and 66.2% of the burden of blindness and vision loss in 1990 and 2019, respectively. The absolute cross-national inequality (SII) fell from −303.5 (95% CI −370.8 to −236.2) in 1990 to −256.0 (95% CI −288.1 to −223.8) in 2019. The relative inequality (concentration index) for global blindness and vision loss remained essentially constant between 1991 (−0.197, 95% CI −0.234 to −0.160) and 2019 (−0.193, 95% CI −0.216 to −0.169). Conclusion Though countries with middle and low-middle SDI were the most successful in decreasing burden of blindness and vision loss, a high level of cross-national health inequality persisted over the past three decades. More attention must be paid to the elimination of avoidable blindness and vision loss in low-income and middle-income countries.

1 January 2024 in Journal of Ophthalmology
Verified
Journal Article
Open access
XZXin Zhong
Xin Zhong
YLYan Li
Yan Li
YLYuancun Li
Yuancun Li
GWGeng Wang
Geng Wang
YDYali Du
Yali Du
MZMingzhi Zhang
Mingzhi Zhang
Background. This study aims to investigate the agreement between the NK and KS formulas in predicting the vault after implantation of an EVO‐implantable collamer lens (ICL). Methods. This retrospective study included 106 eyes of 57 patients who underwent ICL‐V4c implantation. Preoperative vault prediction was conducted by utilizing the NK and KS formulas, with postoperative measurements by anterior segment optical coherence tomography (AS‐OCT) at one month. The analysis focused on the consistency between predicted and achieved vaults, as well as the correlation between the achieved vault and various biometric parameters. Results. The mean achieved vault was 605.25 ± 212.72 µm, which was significantly smaller than the predicted vaults of 710.08 ± 195.08 and 673.80 ± 212.76 µm, using the NK and KS formulas, respectively (P < 0.05). The mean differences between the achieved vault and the predicted vault using the NK formula and KS formula were −104.82 μm (95% LoA: −600.38–391.19 μm) and −68.55 μm (95% LoA: −628.91–491.82 μm), respectively. Anterior chamber depth (ACD), vertical sulcus‐to‐sulcus (V‐STS) diameter, and crystalline lens rise (CLR) were independent factors associated with the achieved vault (P < 0.05). The two formulas showed no statistically significant difference in absolute prediction error (APE). Conclusion. The NK formula exhibited superior consistency and low predictive error compared to the KS formula in the 12.6 mm ICL group. AS‐OCT measurements overestimated the predicted ICL vault, especially in the 13.2 mm ICL size selection. Relying solely on the NK or KS formulas for predicting vaults before ICL surgery is not recommended.

14 October 2023 in Research Square
Verified
Preprint
Open access
PDF file
XZXin Zhong
Xin Zhong
YLYan Li
Yan Li
YLYuancun Li
Yuancun Li
GWGeng Wang
Geng Wang
YDYali Du
Yali Du
MZMingzhi Zhang
Mingzhi Zhang
Background The purpose of this study is to investigate the agreement of NK and KS formulas in predicting the vault after implantation of EVO-implantable collamer lens (ICL).Methods In this retrospective study, a total of 106 eyes of 59 patients who underwent ICL-V4c implantation were included. The predicted vault using the NK formula and the KS formula was provided by anterior segment optical coherence tomography (AS-OCT) automatically. The achieved vault was measured by AS-OCT at 1 month after surgery. Multivariate linear regression analyses were performed for evaluating correlations between postoperative vault and other biological parameters.Results The achieved vault was 604.34 ± 214.66 µm, which was significantly smaller than the predicted vaults of 713.50 ± 195.32 and 679.27 ± 211.00 µm, using the NK and KS formulas, respectively (P < 0.05). The 95% limits of agreement of the achieved vault and the predicted vault using the KS formula were narrower than those of the achieved vault and the predicted vault using the NK formula in both ICL size groups. Anterior chamber depth (ACD) and sulcus-to-sulcus diameter (STS) were independent factors associated with achieved vault (P < 0.05). It’s no significant difference in absolute prediction error (APE) between the two formulas.Conclusion There is no significant difference between the NK and KS formulas in terms of absolute predicted error vault. It should be noted that AS-OCT tended to overestimate the predicted ICL vault, particularly when selecting larger ICL sizes. ACD and STS were identified as potential crucial factors influencing the achieved vault.

11 July 2023 in Research Square
Verified
Preprint
Open access
PDF file
XZXin Zhong
Xin Zhong
TLTong Li
Tong Li
YDYali Du
Yali Du
Background Implantable Collamer Lens (ICL) surgery is a beneficial option for correcting high myopia due to its stable long-term outcomes and improved night vision with a wider optical zone. The reversible procedure is particularly useful for high myopia correction. Traumatic displacement of ICL is rare but carries the potential to develop vision-threatening complication. Timely intervention with thoroughly consideration of surgical planning remains challenging. We present a rare case of traumatic dislocation and pupillary capture of the ICL after blunt trauma, in which the patient underwent surgical intervention of ICL repositioning. Case presentation A 44-year-old man presented with a loss of vision in his left eye, accompanied by photophobia and pain, after receiving blunt ocular trauma from a fist one hour ago. This patient had undergone bilateral ICL implantation for high myopia four years prior to presentation. On examination, one footplate of the ICL was entrapped in the pupillary, located on the nasal side of the iris. The patient showed 4+ red blood cells and Grade I hyphema in the anterior chamber of his left eye, along with moderate vitreous hemorrhage and slight angle recession at the 9 o'clock position. The dislocation and pupillary capture of the ICL were surgically corrected to a horizontal position under topical anesthesia one week after the injury, resulting in a stable location in his left eye with stable postoperative vault. Conclusion Traumatic ICL dislocation is rare but poses the risk of long-term complications. Prompt intervention can lessen the chances of complications in difficult cases. Thorough examination is vital to quickly identify and diagnose the dislocation, which may mitigate potential vision-threatening complications.

18 November 2024 in International Journal of Ophthalmology
Verified
Journal Article
Open access
PDF file
XZXin Zhong
Xin Zhong
TLTong Li
Tong Li
YDYali Du
Yali Du
MZMingzhi Zhang
Mingzhi Zhang

20 July 2026 in British Journal of Ophthalmology
Verified
Journal Article
Closed access
PDF file
ZGZhiqiang Guan
Zhiqiang Guan
YLYongyi Li
Yongyi Li
YLYuancun Li
Yuancun Li
ZQZhen Qian
Zhen Qian
YDYali Du
Yali Du
KQKunliang Qiu
Kunliang Qiu
Background and aims: The current study aims to investigate how age, period and cohort effects have shaped the patterns of diabetic retinopathy-related vision loss globally, distinguishing between loss associated with type 1 versus 2 diabetes. Methods: A secondary analysis of data from the Global Burden of Disease (GBD) 2021 study was conducted by using estimates of blindness and vision loss due to DR across different socio-demographic index (SDI) categories. Age-standardised prevalence rates, relative percentage changes, net drift and local drift were analysed. Findings: Globally, age-standardised prevalence (ASPR) of diabetes-related blindness and vision loss rose from 48.8 per 100 000 in 1990 to 67.3 per 100 000 in 2021, with type 1 diabetes-related blindness and vision loss ASPR showing a modest decrease (from 1.8 to 1.7 per 100 000). The highest relative increase was recorded in the high SDI group (45.8%). For Type 1 diabetes, low-middle and low SDI groups exhibited more pronounced declines in associated ASPR. Increasing ASPR with advancing age was consistent across SDI groups though less pronounced for type 1 than type 2 diabetes. Unfavourable period and cohort effects were observed for type 2 but not type 1-related blindness and vision loss risk. High-middle SDI and middle SDI groups showed the most notable increase in period and cohort effect, whereas low-middle and low SDI groups experienced favourable period and cohort risks during the study duration. Conclusions: Substantially different trends were observed for ASPR, period and cohort effects in recent decades for type 1 versus type 2 diabetes across different SDI.