Donatella Dragone

Ms. Donatella Dragone

University Magna Graecia of Catanzaro
orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 January 2022 in Actuators
Verified
Journal Article
Open access
PDF file
Donatella DragoneDonatella Dragone
Donatella Dragone
Randazzini LuigiRandazzini Luigi
Randazzini Luigi
Alessia CapaceAlessia Capace
Alessia Capace
FNFrancesca Nesci
Francesca Nesci
Carlo COSENTINOCarlo COSENTINO
Carlo COSENTINO
Alessio MEROLAAlessio MEROLA
Alessio MEROLA
This paper presents the mechatronic design of a biorobotic joint with controllable compliance, for innovative applications of “assist-as-needed” robotic rehabilitation mediated by a wearable and soft exoskeleton. The soft actuation of robotic exoskeletons can provide some relevant advantages in terms of controllable compliance, adaptivity and intrinsic safety of the control performance of the robot during the interaction with the patient. Pneumatic Artificial Muscles (PAMs), which belong to the class of soft actuators, can be arranged in antagonistic configuration in order to exploit the variability of their mechanical compliance for the optimal adaptation of the robot performance during therapy. The coupling of an antagonistic configuration of PAMs with a regulation mechanism can achieve, under a customized control strategy, the optimal tuning of the mechanical compliance of the exoskeleton joint over full ranges of actuation pressure and joint rotation. This work presents a novel mechanism, for the optimal regulation of the compliance of the biorobotic joint, which is characterized by a soft and hybrid actuation exploiting the storage/release of the elastic energy by bistable Von Mises elastic trusses. The contribution from elastic Von Mises structure can improve both the mechanical response of the soft pneumatic bellows actuating the regulation mechanism and the intrinsic safety of the whole mechanism. A comprehensive set of design steps is presented here, including the optimization of the geometry of the pneumatic bellows, the fabrication process through 3D printing of the mechanism and some experimental tests devoted to the characterization of the hybrid soft actuation. The experimental tests replicated the main operating conditions of the regulation mechanism; the advantages arising from the bistable hybrid soft actuation were evaluated in terms of static and dynamic performance, e.g., pressure and force transition thresholds of the bistable mechanism, linearity and hysteresis of the actuator response.

15 February 2023 in Bioengineering
Verified
Journal Article
Open access
PDF file
Carlo RicciardiCarlo Ricciardi
Carlo Ricciardi
Francesco AmatoFrancesco Amato
Francesco Amato
ATAnnarita Tedesco
Annarita Tedesco
Donatella DragoneDonatella Dragone
Donatella Dragone
Carlo COSENTINOCarlo COSENTINO
Carlo COSENTINO
MRMaria Romano
Maria Romano
Cardiotocography (CTG) is one of the fundamental prenatal diagnostic methods for both antepartum and intrapartum fetal surveillance. Although it has allowed a significant reduction in intrapartum and neonatal mortality and morbidity, its diagnostic accuracy is, however, still far from being fully satisfactory. In particular, the identification of uncertain and suspicious CTG traces remains a challenging task for gynecologists. The introduction of computerized analysis systems has enabled more objective evaluations, possibly leading to more accurate diagnoses. In this work, the problem of classifying suspicious CTG recordings was addressed through a machine learning approach. A machine-based labeling was proposed, and a binary classification was carried out using a support vector machine (SVM) classifier to distinguish between suspicious and normal CTG traces. The best classification metrics showed accuracy, sensitivity, and specificity values of 92%, 92%, and 90%, respectively. The main results were compared both with results obtained by considering a more unbalanced dataset and with relevant literature studies in the field. The use of the SVM proved to be promising in the field of CTG classification. However, appropriate feature selection and dataset balancing are crucial to achieve satisfactory performance of the classifier.

6 September 2023 in Micromachines
Verified
Journal Article
Open access
PDF file
Donatella DragoneDonatella Dragone
Donatella Dragone
FDFrancesca Federica Donadio
Francesca Federica Donadio
CMChiara Mirabelli
Chiara Mirabelli
Carlo COSENTINOCarlo COSENTINO
Carlo COSENTINO
Francesco AmatoFrancesco Amato
Francesco Amato
Alessio MEROLAAlessio MEROLA
Alessio MEROLA
A minimally-invasive manipulator characterized by hyper-redundant kinematics and embedded sensing modules is presented in this work. The bending angles (tilt and pan) of the robot tip are controlled through tendon-driven actuation; the transmission of the actuation forces to the tip is based on a Bowden-cable solution integrating some channels for optical fibers. The viability of the real-time measurement of the feedback control variables, through optoelectronic acquisition, is evaluated for automated bending of the flexible endoscope and trajectory tracking of the tip angles. Indeed, unlike conventional catheters and cannulae adopted in neurosurgery, the proposed robot can extend the actuation and control of snake-like kinematic chains with embedded sensing solutions, enabling real-time measurement, robust and accurate control of curvature, and tip bending of continuum robots for the manipulation of cannulae and microsurgical instruments in neurosurgical procedures. A prototype of the manipulator with a length of 43 mm and a diameter of 5.5 mm has been realized via 3D printing. Moreover, a multiple regression model has been estimated through a novel experimental setup to predict the tip angles from measured outputs of the optoelectronic modules. The sensing and control performance has also been evaluated during tasks involving tip rotations.

30 August 2024 in Actuators
Verified
Journal Article
Open access
PDF file
FDFrancesca Federica Donadio
Francesca Federica Donadio
Donatella DragoneDonatella Dragone
Donatella Dragone
Anna ProcopioAnna Procopio
Anna Procopio
Francesco AmatoFrancesco Amato
Francesco Amato
Carlo COSENTINOCarlo COSENTINO
Carlo COSENTINO
Alessio MEROLAAlessio MEROLA
Alessio MEROLA
This paper describes the design and characterisation of a novel hybrid pneumatic rotational actuator that aims to overcome the limitations of both rigid and soft actuators while combining their advantages; indeed, the designed actuator consists of a soft air chamber having an auxetic structure constrained between two rigid frames connected by a soft hinge joint inspired by the musculoskeletal structure of a lobster leg. The main goal is to integrate the advantages of soft actuation, such as inherent compliance and safe human–robot interaction, with those of rigid components, i.e., the robustness and structural stability limiting the ineffective expansion of the soft counterpart of the actuator. The air chamber and its auxetic structure are capable of leveraging the hyper-elastic properties of the soft fabrication material, thereby optimising the response and extending the operational range of the rotational actuator. Each component of the hybrid actuator is fabricated using a 3D-printing method based on Fused Deposition Modeling technology; the soft components are made of thermoplastic polyurethane, and the rigid components are made of polylactic acid. The design phases were followed by some experimental tests to characterise the hybrid actuation by reproducing the typical operating conditions of the actuator itself. In particular, the actuator response in unconstrained expansion and isometric and isobaric conditions has been evaluated. The experimental results show linearity, good repeatability, and sensitivity of the actuator response vs. pneumatic pressure input, other than a small percentage hysteresis, which is ten times less than that observed in commercial soft pneumatic actuators.

6 March 2023 in Smart Materials and Structures
Verified
Journal Article
Closed access
Donatella DragoneDonatella Dragone
Donatella Dragone
Randazzini LuigiRandazzini Luigi
Randazzini Luigi
GSGianni Stano
Gianni Stano
Alessia CapaceAlessia Capace
Alessia Capace
FNFrancesca Nesci
Francesca Nesci
Alessio MEROLAAlessio MEROLA
Alessio MEROLA
This work presents the main steps of design and testing of a novel haptic interface and adaptive admittance control scheme for optimal regulation of the human–machine interaction in hand rehabilitation mediated by a smart system in virtual–reality environment. The prototype development is the result of an integrated HW/SW design and, moreover, the advantages from additive manufacturing techniques and mechanical properties of soft materials are exploited for the realization steps. Indeed, to make the interface smart, a network of piezo-resistive force sensors is embedded into the user’s command interface and the acquired signals are used for the adaptive regulation of human–machine interaction. Another distinctive feature of the haptic interface, which enables to identify this latter as a smart system, is the interaction control based on the estimation of the user’s intention within a novel scheme of adaptive admittance control. The enhanced training process in rehabilitation assisted by the haptic interface and virtual environment has been experimentally validated during a series of goal-directed tasks. The improvement of the motor performance of the user under the assistance of the adaptive admittance control has been experimentally evaluated. Further results show that the rehabilitation system supports the quantitative assessment of the robustness of the motor learning performance of the hand under the generation of haptic disturbances.

1 July 2026 in International Journal of Robust and Nonlinear Control
Verified
Journal Article
Open access
Alessio MEROLAAlessio MEROLA
Alessio MEROLA
FNFrancesca Nesci
Francesca Nesci
Donatella DragoneDonatella Dragone
Donatella Dragone
Francesco MontefuscoFrancesco Montefusco
Francesco Montefusco
Francesco AmatoFrancesco Amato
Francesco Amato
Carlo COSENTINOCarlo COSENTINO
Carlo COSENTINO
This paper presents novel results regarding the input–output finite‐time stability (IO‐FTS) of nonlinear quadratic systems (NLQSs), a class of dynamical models particularly useful for the study of robotic systems, biochemical reaction networks, and other processes of interest to the applied sciences. After introducing the class of nonautonomous NLQSs, a sufficient condition ensuring the IO‐FTS of NLQSs, with time‐varying parameters and subject to input disturbances, represents the first main contribution. The analysis conditions are then exploited to develop state‐ and output‐feedback control laws that achieve IO finite‐time stabilization for an assigned NLQS. These sufficient conditions are expressed in terms of feasibility problems based on linear matrix inequalities (LMIs), which can be efficiently solved via off‐the‐shelf numerical tools. The applicability of the devised results is illustrated throughout the paper using examples of analysis and synthesis related to flight control systems described by NLQSs with time‐varying parameters.