Randazzini Luigi

Mr. Randazzini Luigi

Biomechatronics Laboratory University Magna Grecia of Catanzaro
orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 January 2022 in Actuators
Verified
Journal Article
Open access
PDF file
Donatella DragoneDonatella Dragone
Donatella Dragone
Randazzini LuigiRandazzini Luigi
Randazzini Luigi
Alessia CapaceAlessia Capace
Alessia Capace
FNFrancesca Nesci
Francesca Nesci
Carlo COSENTINOCarlo COSENTINO
Carlo COSENTINO
Alessio MEROLAAlessio MEROLA
Alessio MEROLA
This paper presents the mechatronic design of a biorobotic joint with controllable compliance, for innovative applications of “assist-as-needed” robotic rehabilitation mediated by a wearable and soft exoskeleton. The soft actuation of robotic exoskeletons can provide some relevant advantages in terms of controllable compliance, adaptivity and intrinsic safety of the control performance of the robot during the interaction with the patient. Pneumatic Artificial Muscles (PAMs), which belong to the class of soft actuators, can be arranged in antagonistic configuration in order to exploit the variability of their mechanical compliance for the optimal adaptation of the robot performance during therapy. The coupling of an antagonistic configuration of PAMs with a regulation mechanism can achieve, under a customized control strategy, the optimal tuning of the mechanical compliance of the exoskeleton joint over full ranges of actuation pressure and joint rotation. This work presents a novel mechanism, for the optimal regulation of the compliance of the biorobotic joint, which is characterized by a soft and hybrid actuation exploiting the storage/release of the elastic energy by bistable Von Mises elastic trusses. The contribution from elastic Von Mises structure can improve both the mechanical response of the soft pneumatic bellows actuating the regulation mechanism and the intrinsic safety of the whole mechanism. A comprehensive set of design steps is presented here, including the optimization of the geometry of the pneumatic bellows, the fabrication process through 3D printing of the mechanism and some experimental tests devoted to the characterization of the hybrid soft actuation. The experimental tests replicated the main operating conditions of the regulation mechanism; the advantages arising from the bistable hybrid soft actuation were evaluated in terms of static and dynamic performance, e.g., pressure and force transition thresholds of the bistable mechanism, linearity and hysteresis of the actuator response.

6 March 2023 in Smart Materials and Structures
Verified
Journal Article
Closed access
Donatella DragoneDonatella Dragone
Donatella Dragone
Randazzini LuigiRandazzini Luigi
Randazzini Luigi
GSGianni Stano
Gianni Stano
Alessia CapaceAlessia Capace
Alessia Capace
FNFrancesca Nesci
Francesca Nesci
Alessio MEROLAAlessio MEROLA
Alessio MEROLA
This work presents the main steps of design and testing of a novel haptic interface and adaptive admittance control scheme for optimal regulation of the human–machine interaction in hand rehabilitation mediated by a smart system in virtual–reality environment. The prototype development is the result of an integrated HW/SW design and, moreover, the advantages from additive manufacturing techniques and mechanical properties of soft materials are exploited for the realization steps. Indeed, to make the interface smart, a network of piezo-resistive force sensors is embedded into the user’s command interface and the acquired signals are used for the adaptive regulation of human–machine interaction. Another distinctive feature of the haptic interface, which enables to identify this latter as a smart system, is the interaction control based on the estimation of the user’s intention within a novel scheme of adaptive admittance control. The enhanced training process in rehabilitation assisted by the haptic interface and virtual environment has been experimentally validated during a series of goal-directed tasks. The improvement of the motor performance of the user under the assistance of the adaptive admittance control has been experimentally evaluated. Further results show that the rehabilitation system supports the quantitative assessment of the robustness of the motor learning performance of the hand under the generation of haptic disturbances.

28 August 2020 in Actuators
Verified
Journal Article
Open access
PDF file
Randazzini LuigiRandazzini Luigi
Randazzini Luigi
Alessia CapaceAlessia Capace
Alessia Capace
Carlo COSENTINOCarlo COSENTINO
Carlo COSENTINO
Rosa Daniela GrembialeRosa Daniela Grembiale
Rosa Daniela Grembiale
Francesco AmatoFrancesco Amato
Francesco Amato
Alessio MEROLAAlessio MEROLA
Alessio MEROLA
In the current clinical practice, the diagnosis of Rheumatoid Arthritis (RA) draws on the qualitative evaluation of pain sensitivity thresholds which is affected by several source of uncertainties, due to an operator-dependent diagnostic protocol. Taking our cue from the diagnostic shortcomings, we have explored the possibility of automating the measurement of mechanical nociceptive thresholds through the adoption of soft pneumatic actuators controlled by an embedded control unit. In this work, we want to show that a purpose-made biomechatronic device actuated by soft and pneumatic actuators is potentially a boon both for rheumatologists and biomedical researchers involved in nociception and physicophysical studies. In the full breadth and scope of the objective diagnosis of RA, the first prototype of a novel biomechatronic device for quantitative and automatic measurement of mechanical nociceptive thresholds has been designed and tested through nociception experiments on 10 subjects. The experimental results show that the designed device can reliably generate the controllable and repeatable nociceptive stimuli needed for the objective diagnosis of RA.