Jie Zhou

Dr. Jie Zhou

Department of Biomechanical Engineering, Delft University of Technology, Mekelweg 2, 2628 CD Delft, The Netherlands
orcid

Research Focus & Metrics

Academic Career Length

37Years (1990-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2018 in Acta Biomaterialia
Verified
Journal Article
Closed access
Yageng LiYageng Li
Yageng Li
Jie ZhouJie Zhou
Jie Zhou
PPP. Pavanram
P. Pavanram
MLM.A. Leeflang
M.A. Leeflang
LFL.I. Fockaert
L.I. Fockaert
Amir A ZadpoorAmir A Zadpoor
Amir A Zadpoor

1 February 2018 in Journal of Alloys and Compounds
Verified
Journal Article
Closed access
XZXiang-Yu Zhang
Xiang-Yu Zhang
Gang FangGang Fang
Gang Fang
SLSander Leeflang
Sander Leeflang
ABAmarante J. Böttger
Amarante J. Böttger
Amir A ZadpoorAmir A Zadpoor
Amir A Zadpoor
Jie ZhouJie Zhou
Jie Zhou

1 January 2019 in Acta Biomaterialia
Verified
Journal Article
Closed access
XZXiang-Yu Zhang
Xiang-Yu Zhang
Gang FangGang Fang
Gang Fang
SLSander Leeflang
Sander Leeflang
Amir A ZadpoorAmir A Zadpoor
Amir A Zadpoor
Jie ZhouJie Zhou
Jie Zhou

1 September 2018 in Acta Biomaterialia
Verified
Journal Article
Closed access
Yageng LiYageng Li
Yageng Li
Holger JahrHolger Jahr
Holger Jahr
KLK. Lietaert
K. Lietaert
PPP. Pavanram
P. Pavanram
AYA. Yilmaz
A. Yilmaz
Amir A ZadpoorAmir A Zadpoor
Amir A Zadpoor

9 June 2010 in Journal of Materials Science: Materials in Medicine
Verified
Journal Article
Open access
PDF file
ZHZ. G. Huan
Z. G. Huan
MLM. A. Leeflang
M. A. Leeflang
Jie ZhouJie Zhou
Jie Zhou
LFL. E. Fratila-Apachitei
L. E. Fratila-Apachitei
JDJ. Duszczyk
J. Duszczyk
Zinc and zirconium were selected as the alloying elements in biodegradable magnesium alloys, considering their strengthening effect and good biocompatibility. The degradation rate, hydrogen evolution, ion release, surface layer and in vitro cytotoxicity of two Mg–Zn–Zr alloys, i.e. ZK30 and ZK60, and a WE-type alloy (Mg–Y–RE–Zr) were investigated by means of long-term static immersion testing in Hank’s solution, non-static immersion testing in Hank’s solution and cell-material interaction analysis. It was found that, among these three magnesium alloys, ZK30 had the lowest degradation rate and the least hydrogen evolution. A magnesium calcium phosphate layer was formed on the surface of ZK30 sample during non-static immersion and its degradation caused minute changes in the ion concentrations and pH value of Hank’s solution. In addition, the ZK30 alloy showed insignificant cytotoxicity against bone marrow stromal cells as compared with biocompatible hydroxyapatite (HA) and the WE-type alloy. After prolonged incubation for 7 days, a stimulatory effect on cell proliferation was observed. The results of the present study suggested that ZK30 could be a promising material for biodegradable orthopedic implants and worth further investigation to evaluate its in vitro and in vivo degradation behavior.

1 October 2020 in Acta Biomaterialia
Verified
Journal Article
Open access
Yageng LiYageng Li
Yageng Li
Holger JahrHolger Jahr
Holger Jahr
Jie ZhouJie Zhou
Jie Zhou
AZAmir Abbas Zadpoor
Amir Abbas Zadpoor
Partially due to the unavailability of ideal bone substitutes, the treatment of large bony defects remains one of the most important challenges of orthopedic surgery. Additively manufactured (AM) biodegradable porous metals that have emerged since 2018 provide unprecedented opportunities for fulfilling the requirements of an ideal bone implant. First, the multi-scale geometry of these implants can be customized to mimic the human bone in terms of both micro-architecture and mechanical properties. Second, a porous structure with interconnected pores possesses a large surface area, which is favorable for the adhesion and proliferation of cells and, thus, bony ingrowth. Finally, the freeform geometrical design of such biomaterials could be exploited to adjust their biodegradation behavior so as to maintain the structural integrity of the implant during the healing process while ensuring that the implant disappears afterwards, paving the way for full bone regeneration. While the AM biodegradable porous metals that have been studied so far have shown many unique properties as compared to their solid counterparts, the unprecedented degree of flexibility in their geometrical design has not yet been fully exploited to optimize their properties and performance. In order to develop the ideal bone implants, it is important to take advantage of the full potential of AM biodegradable porous metals through detailed and systematic study on their biodegradation behavior, mechanical properties, biocompatibility, and bone regeneration performance. This review paper presents the state of the art in AM biodegradable porous metals and is focused on the effects of material type, processing, geometrical design, and post-AM treatments on the mechanical properties, biodegradation behavior, in vitro biocompatibility, and in vivo bone regeneration performance of AM porous Mg, Fe, and Zn as well as their alloys. We also identify a number of knowledge gaps and the challenges encountered in adopting AM biodegradable porous metals for orthopedic applications and suggest some promising areas for future research.