Numerous screw fixation systems have evolved in clinical practice as a result of advances in screw insertion technology. Currently, pedicle screw (PS) fixation technology is recognized as the gold standard of posterior lumbar fusion, but it can also have some negative complications, such as screw loosening, pullout, and breakage. To address these concerns, cortical bone trajectory (CBT) has been proposed and gradually developed. However, it is still unclear whether cortical bone trajectory can achieve similar mechanical stability to pedicle screw and whether the combination of pedicle screw + cortical bone trajectory fixation can provide a suitable mechanical environment in the intervertebral space. The present study aimed to investigate the biomechanical responses of the lumbar spine with pedicle screw and cortical bone trajectory fixation. Accordingly, finite element analysis (FEA) and in vitro specimen biomechanical experiment (IVE) were performed to analyze the stiffness, range of motion (ROM), and stress distribution of the lumbar spine with various combinations of pedicle screw and cortical bone trajectory screws under single-segment and dual-segment fixation. The results show that dual-segment fixation and hybrid screw placement can provide greater stiffness, which is beneficial for maintaining the biomechanical stability of the spine. Meanwhile, each segment’s range of motion is reduced after fusion, and the loss of adjacent segments’ range of motion is more obvious with longer fusion segments, thereby leading to adjacent-segment disease (ASD). Long-segment internal fixation can equalize total spinal stresses. Additionally, cortical bone trajectory screws perform better in terms of the rotation resistance of fusion segments, while pedicle screw screws perform better in terms of flexion–extension resistance, as well as lateral bending. Moreover, the maximum screw stress of L4 cortical bone trajectory/L5 pedicle screw is the highest, followed by L45 cortical bone trajectory. This biomechanical analysis can accordingly provide inspiration for the choice of intervertebral fusion strategy.

14 September 2023 in Frontiers in Bioengineering and Biotechnology
Verified
Journal Article
Open access
BPBaoqing Pei
Baoqing Pei
MHMengyuan Hu
Mengyuan Hu
XWXueqing Wu
Xueqing Wu
DLDa Lu
Da Lu
SZShijia Zhang
Shijia Zhang
SWShuqin Wu
Shuqin Wu
In recent years, bone tissue engineering (BTE) has played an essential role in the repair of bone tissue defects. Although bioactive factors as one component of BTE have great potential to effectively promote cell differentiation and bone regeneration, they are usually not used alone due to their short effective half-lives, high concentrations, etc. The release rate of bioactive factors could be controlled by loading them into scaffolds, and the scaffold microstructure has been shown to significantly influence release rates of bioactive factors. Therefore, this review attempted to investigate how the scaffold microstructure affected the release rate of bioactive factors, in which the variables included pore size, pore shape and porosity. The loading nature and the releasing mechanism of bioactive factors were also summarized. The main conclusions were achieved as follows: i) The pore shapes in the scaffold may have had no apparent effect on the release of bioactive factors but significantly affected mechanical properties of the scaffolds; ii) The pore size of about 400 μm in the scaffold may be more conducive to controlling the release of bioactive factors to promote bone formation; iii) The porosity of scaffolds may be positively correlated with the release rate, and the porosity of 70%–80% may be better to control the release rate. This review indicates that a slow-release system with proper scaffold microstructure control could be a tremendous inspiration for developing new treatment strategies for bone disease. It is anticipated to eventually be developed into clinical applications to tackle treatment-related issues effectively.

15 April 2022 in Materials
Verified
Journal Article
Open access
PDF file
BPBaoqing Pei
Baoqing Pei
LGLei Guo
Lei Guo
XWXueqing Wu
Xueqing Wu
MHMengyuan Hu
Mengyuan Hu
SWShuqin Wu
Shuqin Wu
Yangwei WangYangwei Wang
Yangwei Wang
The turtle carapace has a high level of protection, due to its unique biological structure, and there is great potential to use the turtle carapace structure to improve the impact resistance of composite materials using bionic theory. In this paper, the chemical elements of the turtle carapace structure, as well as its mechanical properties, were investigated by studying the composition of the compounds in each part. In addition, the bionic sandwich structure, composed of the plate, core, and backplate, was designed using modeling software based on the microstructure of the keratin scutes, spongy bone, and the spine of the turtle carapace. Additionally, finite element analysis and drop-weight experiments were utilized to validate the impact-resistant performance of the bionic structures. The numerical results show that all of the bionic structures had improved impact resistance to varying degrees when compared with the control group. The experimental results show that the split plate, the core with changing pore gradients, and the backplate with stiffener all have a considerable effect on the impact-resistance performance of overall composite structures. This preliminary study provides theoretical support for composite material optimization.

29 July 2022 in PLOS ONE
Verified
Journal Article
Open access
PDF file
WWWei Wang
Wei Wang
BPBaoqing Pei
Baoqing Pei
SWShuqin Wu
Shuqin Wu
DLDa Lu
Da Lu
PHPeiyan He
Peiyan He
XWXueqing Wu
Xueqing Wu
Background: Few studies have analyzed the different biomechanical properties of the lumbar with various morphological parameters, which play an important role in injury and degeneration. This study aims to preliminarily investigate biomechanical characteristics of the spine with different sagittal alignment morphotypes by using finite element (FE) simulation and in-vitro testing. Methods: According to the lumbar-pelvic radiographic parameters of the Chinese population, the parametric FE models (L1-S1-pelvis) of Roussouly’s type (1–4) were validated and developed based on the in-vitro biomechanical testing. A pure moment of 7.5 Nm was applied in the three anatomical planes to simulate the physiological activities of flexion, extension, left-right lateral bending and left-right axial rotation. Results: The sagittal configuration of four Roussouly’s type models had a strong effect on the biomechanical responses in flexion and extension. The apex of the lumbar lordosis is a critical position where the segment has the lowest range of motion among all the models. In flexion-extension, type 3 and 4 models with a good lordosis shape had a more uniform rotation distribution at each motor function segment, however, type 1 and 2 models with a straighter spine had a larger proportion of rotation at the L5-S1 level. In addition, type 1 and 2 models had higher intradiscal pressures (IDPs) at the L4-5 segment in flexion, while type 4 model had larger matrix and fiber stresses at the L5-S1 segment in extension. Conclusion: The well-marched lordotic type 3 lumbar had greater stability, however, a straighter spine (type 1 and 2) had poor balance and load-bearing capacity. The hypolordotic type 4 model showed larger annulus fiber stress. Therefore, the sagittal alignment of Roussouly’s type models had different kinetic and biomechanical responses under various loading conditions, leading to different clinical manifestations of the lumbar disease.

15 September 2021 in Journal of Nanomaterials
Verified
Journal Article
Open access
PDF file
DLDa Lu
Da Lu
XWXueqing Wu
Xueqing Wu
WWWei Wang
Wei Wang
CMChenghao Ma
Chenghao Ma
BPBaoqing Pei
Baoqing Pei
SWShuqin Wu
Shuqin Wu
Nanoparticles play a vital role in bone tissue repair engineering, especially iron oxide nanoparticles (IONPs), which have magnetic properties, semiconductor properties, and nontoxicity at the same time, and their applications in biomedicine have received widespread attention. This review summarizes the excellent performance of IONPs in enhancing scaffold functions, promoting stem cell differentiation, and labeling positioning, in order to understand the research progress and future development trends of IONPs in bone tissue repair engineering, as well as the security issues. Firstly, IONPs can affect the expression of genes and proteins to accelerate the process of biomineralization under a magnetic field. Then, the composite of IONPs and polymers can synthesize a scaffold which can promote the attachment, proliferation, and bone differentiation of stem cells. Furthermore, IONPs can also mark the location of drugs in the body to follow up the process of bone repair. Therefore, extensive research on the manufacturing and application range of IONPs is of great significance to bone tissue repair engineering.

15 July 2022 in Frontiers in Bioengineering and Biotechnology
Verified
Journal Article
Open access
BPBaoqing Pei
Baoqing Pei
DLDa Lu
Da Lu
XWXueqing Wu
Xueqing Wu
YXYangyang Xu
Yangyang Xu
CMChenghao Ma
Chenghao Ma
SWShuqin Wu
Shuqin Wu
Periodical and consecutive distraction is an effective treatment for severe early onset scoliosis (EOS), which enables the spinal coronal and sagittal plane deformity correction. However, the rate of rod fractures and postoperative complications was still high mainly related to the distraction process. Previous studies have primarily investigated the maximum safe distraction force without a rod broken, neglecting the spinal re-imbalance and distraction energy consumption, which is equally vital to evaluate the operative value. This study aimed to reveal the kinematic and biomechanical responses occurring after spinal distraction surgery, which were affected by traditional bilateral fixation. The spinal models (C6-S1) before four distractions were reconstructed based on CT images and the growing rods were applied with the upward displacement load of 0–25 mm at an interval of 5 mm. Relationships between the distraction distance, the distraction force and the thoracic and lumbar Cobb angle were revealed, and the spinal displacement and rotation in three-dimensional directions were measured. The spinal overall imbalance would also happen during the distraction process even under the safe force, which was characterized by unexpected cervical lordosis and lateral displacement. Additionally, the law of diminishing return has been confirmed by comparing the distraction energy consumption in different distraction distances, which suggests that more attention paid to the spinal kinematic and biomechanical changes is better than to the distraction force. Notably, the selection of fixed segments significantly impacts the distraction force at the same distraction distance. Accordingly, some results could provide a better understanding of spinal distraction surgery.