Pragati Kumar

Dr. Pragati Kumar

orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 October 2012 in Discover Nano
Verified
Journal Article
Open access
PDF file
PKPragati Kumar
Pragati Kumar
NSNupur Saxena
Nupur Saxena
RCRamesh Chandra
Ramesh Chandra
VGVinay Gupta
Vinay Gupta
AAAvinash Agarwal
Avinash Agarwal
DKDinakar Kanjilal
Dinakar Kanjilal
Nanotwin structures are observed in high-resolution transmission electron microscopy studies of cubic phase CdS quantum dots in powder form by chemical co-precipitation method. The deposition of thin films of nanocrystalline CdS is carried out on silicon, glass, and TEM grids keeping the substrates at room temperature (RT) and 200°C by pulsed laser ablation. These films are then subjected to thermal annealing at different temperatures. Glancing angle X-ray diffraction results confirm structural phase transitions after thermal annealing of films deposited at RT and 200°C. The variation of average particle size and ratio of intensities in Raman peaks I 2LO/I 1LO with annealing temperature are studied. It is found that electron-phonon interaction is a function of temperature and particle size and is independent of the structure. Besides Raman modes LO, 2LO and 3LO of CdS at approximately 302, 603, and 903 cm−1 respectively, two extra Raman modes at approximately 390 and 690 cm−1 are studied for the first time. The green and orange emissions observed in photoluminescence are correlated with phase transition.

11 June 2021 in Journal of Physics: Condensed Matter
Verified
Journal Article
Closed access
HWHuaping Wang
Huaping Wang
JMJianmin Ma
Jianmin Ma
JZJun Zhang
Jun Zhang
YFYuezhan Feng
Yuezhan Feng
MVMani Teja Vijjapu
Mani Teja Vijjapu
Jie HuangJie Huang
Jie Huang
Gas sensor technology is widely utilized in various areas ranging from home security, environment and air pollution, to industrial production. It also hold great promise in non-invasive exhaled breath detection and an essential device in future internet of things. The past decade has witnessed giant advance in both fundamental research and industrial development of gas sensors, yet current efforts are being explored to achieve better selectivity, higher sensitivity and lower power consumption. The sensing layer in gas sensors have attracted dominant attention in the past research. In addition to the conventional metal oxide semiconductors, emerging nanocomposites and graphene-like two-dimensional materials also have drawn considerable research interest. This inspires us to organize this comprehensive 2020 gas sensing materials roadmap to discuss the current status, state-of-the-art progress, and present and future challenges in various materials that is potentially useful for gas sensors.

17 December 2022 in Optical and Quantum Electronics
Verified
Journal Article
Closed access
PDF file
SSSundar Singh
Sundar Singh
VKVeerendra Kumar
Veerendra Kumar
STSanjeev Tyagi
Sanjeev Tyagi
NSNupur Saxena
Nupur Saxena
ZKZishan H. Khan
Zishan H. Khan
PKPragati Kumar
Pragati Kumar

1 September 2012 in Physica B: Condensed Matter
Verified
Journal Article
Closed access
PKPragati Kumar
Pragati Kumar
NSNupur Saxena
Nupur Saxena
FSF. Singh
F. Singh
AAAvinash Agarwal
Avinash Agarwal

16 November 2015 in RSC Advances
Verified
Journal Article
Closed access
PDF file
PKPragati Kumar
Pragati Kumar
NSNupur Saxena
Nupur Saxena
SDSheetal Dewan
Sheetal Dewan
FSFouran Singh
Fouran Singh
VGVinay Gupta
Vinay Gupta
A highly sensitive UV-detector is devised for the first time from ion beam irradiated nanocrystalline CdS (nc-CdS) thin films. The UV-sensors are fabricated using pulsed laser deposited nc-CdS thin films on Si wafer and subsequent irradiation treatment. Swift heavy ion irradiation (SHII) of the nc-CdS thin films is carried out using 70 MeV 58Ni6+ ions. The sensors used in the present study are easy to fabricate and require inexpensive materials; they feature characteristics similar to those of UV sensors designed with complex structures and expensive procedures. Current–voltage (I–V) measurements reveal an enrichment in carrier concentration and improvement in conductivity after exposure to SHII. This giant conductivity may be attributed to an enhancement in sulfur vacancies as a consequence of SHII. The sensor exhibits improvements in the responsivity, photosensitivity, and efficiency as a function of the ion fluence and attains maximum values of ∼53 W A−1, 576.4% and 15.6 × 103% respectively for a film irradiated at a fluence of 1 × 1013 ions per cm2. The response time of the sensor reduces with the increase in ion fluence and reaches a minimum of a rise time of 165 ms and fall time of 65 ms at 3 V for these sensors. A possible mechanism involved in the SHII induced moderation of conductivity and consequently photosensitivity is explained on the basis of variation in the defect densities.

1 March 2014 in Journal of Luminescence
Verified
Journal Article
Closed access
PKPragati Kumar
Pragati Kumar
NSNupur Saxena
Nupur Saxena
RCRamesh Chandra
Ramesh Chandra
KGKun Gao
Kun Gao
SZShengqiang Zhou
Shengqiang Zhou
DKD. Kanjilal
D. Kanjilal