Francesco Boselli

Dr. Francesco Boselli

Agostino Gemelli University Polyclinic, Rome, Lazio, Italy

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 November 2022 in International Ophthalmology
Verified
Journal Article
Open access
PDF file
MCMatteo Mario Carlà
Matteo Mario Carlà
FBFrancesco Boselli
Francesco Boselli
FGFederico Giannuzzi
Federico Giannuzzi
TCTomaso Caporossi
Tomaso Caporossi
GGGloria Gambini
Gloria Gambini
SRStanislao Rizzo
Stanislao Rizzo
Background: Complicated cataract surgery is the main cause of secondary lens implantation surgery. Several approaches have been introduced to face those circumstances. As it concerns scleral-fixated IOLs for the posterior chamber, many types of IOL can be implanted. The aim of article is to review the single piece sutureless scleral fixation Carlevale lens; Methods: Narrative review; Results: Several works described as safe the IOL implantation utilizing the handshake approach, without tactile manipulation, which allows for self-centration and lens firm fixation in uncomplicated surgery. This allows to reduce high order aberration such as astigmatism and coma, with a very good postoperative BCVA Conclusions: Carlevale lens is one of the best option to manage insufficient capsular support.

2 April 2022 in Vision
Verified
Journal Article
Open access
PDF file
MCMatteo Mario Carlà
Matteo Mario Carlà
FBFrancesco Boselli
Francesco Boselli
FGFederico Giannuzzi
Federico Giannuzzi
GGGloria Gambini
Gloria Gambini
TCTomaso Caporossi
Tomaso Caporossi
Stanislao RizzoStanislao Rizzo
Stanislao Rizzo
Myopia is becoming more common across the world, affecting approximately two billion people and rising. Different kinds of therapies (optical, pharmaceutical, environmental, or behavioral) have been proposed to decrease myopia progression, but with variable results and a lack of standardization. The evidence that targeted myopic defocus inhibits eye length growth has paved the way for several contact and spectacle lense designs to induce a peripheral defocus, thus slowing myopia progression, but the perfect configuration has yet to be defined. One of the newest and more promising approaches in this field is the use of Defocus Incorporated Multiple Segments (DIMS) lenses. These lenses are built from the assumption that targeted myopic defocus, produced by 396 mid-peripheral lenslets with positive power, inhibits eye length growth. Recent studies have highlighted the effectiveness of these lenses compared to children who had worn single vision spectacle lenses, in terms of myopia control and tolerability. Despite the evidence that these lenses can help slow down the progression of myopia, the occasional mid-peripheral aberrations they can induce, as well as the overall eye strain that comes with wearing them, should not be overlooked. The aim of this review is to give attention to the advantages and the shortfalls of this new approach and to evaluate its effectiveness in clinical practice.

17 May 2022 in Diagnostics
Verified
Journal Article
Open access
PDF file
GGGloria Gambini
Gloria Gambini
MCMatteo Mario Carlà
Matteo Mario Carlà
FGFederico Giannuzzi
Federico Giannuzzi
FBFrancesco Boselli
Francesco Boselli
GGGiulia Grieco
Giulia Grieco
Stanislao RizzoStanislao Rizzo
Stanislao Rizzo
Background: The purpose of this study is to compare the morphology of six-month follow-up blebs created by a subconjunctival glaucoma surgical device (XEN45) to those created by a PreserFlo MicroShunt with a sub-Tenon insertion, utilizing AS-OCT. Methods: A retrospective study of 29 eyes who underwent XEN45 implantation and 29 eyes who underwent PreserFlo MicroShunt implantation. The patients were analyzed at 24 h, 1 week, 1 month, 3 months and 6 months. At each visit, the maturation and morphological alterations of the blebs were observed, as well as connections with the IOP. Results: In both groups, IOP showed significant reduction at all follow ups (p < 0.0001). In XEN group, the most common bleb morphology in the immediate postoperative was the subconjuntival separation type (42%) followed by the uniform type (34%), with a trend inversion at 6 month follow up (51% of uniform type). On the contrary, the most common morphology after PreserFlo was the multiple internal layer (55%), which showed a tendency to reduce over time and was substituted by the microcystic multiform, whose percentage increased over time (17% at day 1 vs. 44% at month 6). Uniform appearance was associated by the posterior episcleral fluid (PEF) lake presence. Both horizontal and vertical diameters significantly increased over time. Conclusion: XEN and PreserFlo implantation resulted in the production of diffuse blebs with different characteristics, which may influence IOP lowering capacity and bleb revisions necessity over time.

Verified
Journal Article
Open access
PDF file
GGGloria Gambini
Gloria Gambini
LSLuca Scartozzi
Luca Scartozzi
FGFederico Giannuzzi
Federico Giannuzzi
MCMatteo Mario Carlà
Matteo Mario Carlà
FBFrancesco Boselli
Francesco Boselli
SRStanislao Rizzo
Stanislao Rizzo
Fabry disease (FD) is an X-linked lysosomal storage disorder, causing Gb-3 (globotriaosylceramide) buildup in cellular lysosomes throughout the body, in particular in blood vessel walls, neuronal cells, and smooth muscle. The gradual accumulation of this glycosphingolipid in numerous eye tissues causes conjunctival vascular abnormalities, corneal epithelial opacities (cornea verticillata), lens opacities, and retinal vascular abnormalities. Although a severe vision impairment is rare, these abnormalities are diagnostic indicators and prognostics for severity. Cornea verticillata is the most common ophthalmic feature in both hemizygous men and heterozygous females. Vessel tortuosity has been linked to a faster disease progression and may be useful in predicting systemic involvement. New technologies such as optical coherence tomography angiography (OCTA) are useful for monitoring retinal microvasculature alterations in FD patients. Along with OCTA, corneal topographic analysis, confocal microscopy, and electro-functional examinations, contributed to the recognition of ocular abnormalities and have been correlated with systemic involvement. We offer an update regarding FD ocular manifestations, focusing on findings derived from the most recent imaging modalities, to optimize the management of this pathology.

17 March 2022 in Diagnostics
Verified
Journal Article
Open access
PDF file
MCMatteo Mario Carlà
Matteo Mario Carlà
FBFrancesco Boselli
Francesco Boselli
FGFederico Giannuzzi
Federico Giannuzzi
GGGloria Gambini
Gloria Gambini
TCTomaso Caporossi
Tomaso Caporossi
Stanislao RizzoStanislao Rizzo
Stanislao Rizzo
Intraoperative optical coherence tomography (iOCT) is a noninvasive imaging technique that gives real-time dynamic feedback on surgical procedures. iOCT was first employed in vitreoretinal surgery, but successively served as a guidance in several anterior segment surgical approaches: keratoplasty, implantable Collamer lens (ICL) implantation, and cataract surgery. Among all of those approaches, the unbeatable features of iOCT are fully exploited in anterior and posterior lamellar keratoplasty, and the purpose of this review is to focus on the advantages and shortfalls of iOCT in these techniques, in order to assess whether this technology could be a real step forward. In deep anterior lamellar keratoplasty (DALK), iOCT is useful to evaluate the needle depth into the corneal stroma, the big bubble dissection plane, and residual stromal bed, thus aiding the standardization of the technique and the reduction of failures. In Descemet stripping automated endothelial keratoplasty (DSAEK), iOCT allowed for clear visibility of fluid at the graft/host interface, allowing for immediate rescue maneuvers and granting the best graft apposition. In Descemet membrane endothelial keratoplasty (DMEK), iOCT can track the lenticule unfolding in real time and assess graft orientation even in severe hazy corneas, thus optimizing surgical times, as well as avoiding the use of potentially hazardous exterior markers (such as the “S” stamp) and preventing unnecessary manipulation of the graft. Overall, the role of iOCT appeared crucial in several complicated cases, overcoming the difficulties of poor visualization in a fast, non-invasive way, thus raising this approach as possible gold standard for challenging conditions. Further improvements in the technology may enable autonomous centering and tracking, overcoming the current constraint of instrument-induced shadowing.

23 February 2024 in Pharmaceutics
Verified
Journal Article
Open access
PDF file
MCMatteo Mario Carlà
Matteo Mario Carlà
MSMaria Cristina Savastano
Maria Cristina Savastano
FBFrancesco Boselli
Francesco Boselli
FGFederico Giannuzzi
Federico Giannuzzi
Stanislao RizzoStanislao Rizzo
Stanislao Rizzo
The ranibizumab (RBZ) port delivery system (PDS) is a device designed to continuously deliver RBZ in the vitreous chamber for the treatment of neovascular age-related macular degeneration (nAMD). It is implanted during a surgical procedure and can provide sustained release of the medication for several months. This review, updated to January 2024, focuses on past clinical studies as well as current and forthcoming trials looking into a PDS with RBZ. In the phase 2 LADDER trial, the mean time to first refill of a PDS with RBZ 100 mg/mL was 15.8 months, with the pharmacokinetic (PK) profile showing a sustained concentration of RBZ in the blood and aqueous humor. More recently, a PDS with RBZ (100 mg/mL) refilled every 24 weeks was shown to be non-inferior to a monthly intravitreal injection (IVI) with RBZ (0.5 mg) over 40 and 92 weeks in the phase 3 ARCHWAY trial. The refill every 24 weeks allowed for a RBZ vitreous exposure within the concentration range of monthly intravitreal injections (IVIs), and the expected half-life (106 days) was comparable with the in vitro results. Nonetheless, vitreous hemorrhage and endophthalmitis were more common side effects in PDS patients. In conclusion, a PDS continuously delivering RBZ has a clinical effectiveness level comparable with IVI treatment. However, a greater frequency of unfavorable occurrences highlights the need for procedure optimization for a wider adoption. Ongoing trials and possible future approaches need to be addressed.