Hasan Naveed

Dr. Hasan Naveed

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 March 2022 in Vision
Verified
Journal Article
Open access
PDF file
ZAZahra Ashena
Zahra Ashena
SGSean Gallagher
Sean Gallagher
HNHasan Naveed
Hasan Naveed
DSDavid J. Spalton
David J. Spalton
Mayank NanavatyMayank Nanavaty
Mayank Nanavaty
This study aimed to assess the anterior corneal wavefront aberrations, keratometry, astigmatism vectors and pupil size between Pentacam HR® (Oculus Optikgeraete GmbH, Wetzlar, Germany) and iTrace® (Tracey Technologies Corp., Houston, TX, USA). In this observational study, 100 eyes (50 healthy volunteers) were scanned in mesopic light condition with a Pentacam HR® and iTrace®. Anterior corneal aberrations (spherical aberration (Z40), vertical coma (Z3 − 1), horizontal coma (Z3 + 1)), keratometry in the flattest (K1) and steepest meridian (K2), mean astigmatism, astigmatic vectors (J0 and J45), and pupil size were measured. We found a significant difference in Z40 (Pentacam®: +0.30 ± 0.11 µm and iTrace®: −0.03 µm ± 0.05 µm; p < 0.01) with no correlation between the devices (r = −0.12, p = 0.22). The devices were in complete agreement for Z3 − 1 (p = 0.78) and Z3 + 1 (p = 0.39), with significant correlation between the machines (r = −0.38, p < 0.01 and r = −0.6, p < 0.01). There was no difference in K1, K2 and mean astigmatism. J0 was negative with both devices (against-the-rule astigmatism), but there was no correlation. J45 was negative with the Pentacam HR® (more myopic oblique astigmatism) but significantly correlated between the devices. Pupil size was smaller with Pentacam HR® (p < 0.01). In summary, these devices cannot be used interchangeably. Corneal Z40 was significantly different with more negative Z40 with iTrace® compared to Pentacam HR®. iTrace® operates with lower illumination, giving larger pupil size than Pentacam HR®, which uses intense blue light during measurement. No correlation was found for J0. Pentacam HR® had a trend to record more negative J45 (myopic oblique astigmatism).

18 February 2022 in Vision
Verified
Journal Article
Open access
PDF file
YSYarrow Scantling-Birch
Yarrow Scantling-Birch
HNHasan Naveed
Hasan Naveed
RMRitika Mukhija
Ritika Mukhija
Mayank NanavatyMayank Nanavaty
Mayank Nanavaty
Smartphone apps are becoming increasingly popular in ophthalmology, one specific area of their application being toric intraocular lens (IOL) surgery for astigmatism correction. Our objective was to identify, review and objectively score smartphone apps applicable to toric IOL calculation and/or axis alignment. This review was divided into three phases. A review was conducted on four major app databases (phase I): National Health Service (NHS) Apps Library, Google Play Store, Apple App Store and Amazon Appstore. A systematic literature review (phase II) was conducted to identify studies for included apps in phase I of our study. Keywords used in both searches included: “toric lens”, “toric IOL”, “refraction”, “astigmatism”, “ophthalmology”, “eye calculator”, “ophthalmology calculator” and “refractive calculator”. Included apps were objectively scored (phase III) by three independent reviewers using the mobile app rating scale (MARS), a validated tool that ranks the quality of mobile health apps using a calculated mean app quality (MAQ) score. Phase I of our study screened 2428 smartphone apps, of which six apps for toric IOL calculation and four apps for axis marking were eligible and were selected for quantitative analysis. Phase II of our study screened 477 studies from PubMed, Medline and Google Scholar. Three studies validating two apps (toriCAM, iToric Patwardhan) in a clinical setting as adjunct tools for preoperative axis marking were identified. Phase III ranked Toric Calculator for iPhone (Apple iOS, MAQ 4.13; average MAQ 3.34 ± 0.54) as the highest-scoring toric IOL calculator, and iToric Patwardhan (Android OS, MAQ 4.13; average MAQ 3.41 ± 0.44) was the highest-scoring axis marker in our study. Our review identified and objectively scored ten smartphone apps available for toric IOL surgery adjuncts. Toric Calculator for iPhone and iToric Patwardhan were the highest-scoring toric IOL calculator and axis marker, respectively. Current literature, though limited, suggests that axis marking smartphone apps can achieve similar levels of misalignment reduction when compared to digital systems.

8 September 2020 in Journal of Craniofacial Surgery
Verified
Journal Article
Closed access
RARabiya Mbbs Aseem
Rabiya Mbbs Aseem
YSYarrow Bsc (Hons) Scantling-Birch
Yarrow Bsc (Hons) Scantling-Birch
HNHasan Naveed
Hasan Naveed
SGSri Mbbs Gore
Sri Mbbs Gore
AMAshraf Mfds (Rcsi) Messiha
Ashraf Mfds (Rcsi) Messiha
IDIndran Mbbch Davagnanam
Indran Mbbch Davagnanam
Background: Midface augmentation and orbital surgery carry an inherent risk of injury to the infraorbital vascular bundle, especially the infraorbital nerve where it exits the infraorbital foramen (IOF). This can result in significant morbidity for the patient, including paresthesia and neuralgia. Studies report significant heterogeneity in IOF position according to gender, ethnicity, and laterality. A knowledge of the relationship of the IOF to regional soft tissue, bony landmarks, and its variation among ethnicities is likely to reduce iatrogenic injuries. Methods: A single-center retrospective computed tomography (CT)-based study was conducted. Twenty Caucasians and 20 Black Africans patients were selected from an existing radiologic database at Moorfields Eye Hospital, London, UK. DICOM image viewing software (Syngo, Siemens Healthineers) was used to record the position of the IOF using standardized sagittal and axial views. Results: There was a statistically significant difference in the horizontal position of the IOF in the 2 races (P = 0.00). The combined measurements were used to derive a rectangular zone of variability measuring 14.30 mm by 10.60 mm. This zone was found to lie 3.50 mm below the infraorbital rim, 7.10 mm medial to the piriform aperture, and 11.60 mm from the lateral orbital rim. Conclusion: A sound knowledge of key facial landmarks is necessitated when performing midface augmentation and orbital surgery. An anatomical safe zone depicting the variation of the IOF will help reduce iatrogenic injury to the infraorbital nerve and prevent patient morbidity.

1 February 2021 in Postgraduate Medical Journal
Verified
Journal Article
Closed access
PDF file
YSYarrow Scantling-Birch
Yarrow Scantling-Birch
RNRichard Newton
Richard Newton
HNHasan Naveed
Hasan Naveed
SRSaul Rajak
Saul Rajak
MBMahmood F Bhutta
Mahmood F Bhutta
Lower respiratory infections are often caused or precipitated by viruses and are a leading cause of global morbidity and mortality. Mutations in these viral genomes can produce highly infectious strains that transmit across species and have the potential to initiate epidemic, or pandemic, human viral respiratory disease. Transmission between humans primarily occurs via the airborne route and is accelerated by our increasingly interconnected and globalised society. To this date, there have been four major human viral respiratory outbreaks in the 21st century. Healthcare workers (HCWs) are at particular risk during respiratory epidemics or pandemics. This is due to crowded working environments where social distancing, or wearing respiratory personal protective equipment for prolonged periods, might prove difficult, or performing medical procedures that increase exposure to virus-laden aerosols, or bodily fluids. This review aims to summarise the evidence and approaches to occupational risk and protection of HCWs during epidemic or pandemic respiratory viral disease.

Verified
Journal Article
Open access
PDF file
MEMohamed Elalfy
Mohamed Elalfy
ANAhmed Negm
Ahmed Negm
SSShady Mohamed Soliman
Shady Mohamed Soliman
HNHasan Naveed
Hasan Naveed
SHSamer Hamada
Samer Hamada
WMWaleed Mohamed Mahran
Waleed Mohamed Mahran
Background: Anterior lamellar keratoplasty (ALK) is a less invasive procedure than PK, and thus avoids many of the intraocular complications associated with PK. DALK can be performed using several different techniques, with either a manual dissection, a keratome or femtosecond-laser assisted dissection, or with a big bubble technique. To analyse the outcomes and compare the results of three deep anterior lamellar keratoplasty (DALK) techniques. Methods: This study included 105 DALK cases performed at Queen Victoria Hospital, East Grinstead, UK, in the period between January 2016 and May 2022. Cases were classified into four groups based on technique: BB-DALK, manual DALK, FS-DALK and ‘converted to PK group’. Results: There was significant improvement in VA and Kmax compared to the preoperative values in all groups. There was no significant difference detected in VA and Kmax between all groups. Conclusions: Performing DALK surgery with any suitable technique (manual, big-bubble or femtosecond-assisted) is effective and causes significant improvements in VA and Kmax, even in cases where a conversion to penetrating keratoplasty is required. However, every technique has its pros and cons and should be tailored according to surgeon preference and individual case pathology.

29 July 2020 in Journal of Ophthalmic and Vision Research
Verified
Journal Article
Open access
PDF file
HNHasan Naveed
Hasan Naveed
VLVictor Leung
Victor Leung
MZMehran Zarei-Ghanavati
Mehran Zarei-Ghanavati
CLChristopher Leak
Christopher Leak
CLChristopher Liu
Christopher Liu
The COVID-19 pandemic necessitates implementation of exposure control measures in all facets of the healthcare sector. Healthcare professionals who work in busy ophthalmology clinics and theaters are amidst the highest at-risk of contracting COVID- 19. The authors review the up-to-date scientific evidence of SARS-CoV-2 transmission to demystify and explain the exposure control options available for ophthalmic workplace and offer insights from an industrial hygiene standpoint. As the we enter the post-COVID world, these measures will be critical to enhance workplace safety, and thus protect patients and staff alike.