Franz Grehn

Franz Grehn

Auto-generated profile, based on publicly available information

Franz Grehn

Department of Ophthalmology, University Medical Centre of the Johannes Gutenberg University Mainz, Mainz, Germany

Research Focus & Metrics

Academic Career Length

26Years (2001-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2009 in Journal of Glaucoma
Verified
Journal Article
Closed access
AFAxel von Freyberg
Axel von Freyberg
MSMichael Sorg
Michael Sorg
MFMartina Msc Fuhrmann
Martina Msc Fuhrmann
CKChristine F. Kreiner
Christine F. Kreiner
JPJens Msc Pfannkuche
Jens Msc Pfannkuche
GGGert Goch
Gert Goch
Purpose An accurate measurement of intraocular pressure (IOP) is still essential for detecting, following-up, and treating glaucoma. The objective of the interdisciplinary project GlauPhon was to prove a new noncontact tonometry principle that analyzes the acoustic oscillation of the eye. Method Three enucleated porcine eyes were infused via the optic nerve with a saline solution. The IOP was adjusted by varying the height of the infusion bottle. A speaker closed one end of a cylindrical pressure chamber and an eye was fixed to the other side. A PC sound card induced the speaker to oscillate by generating a rectangular signal (20 Hz). A pressure sensor recorded the oscillating pressure within the chamber. For each IOP a calculation was performed that characterizes the attenuation profile. Results Each series of measurements revealed an evident dependency between the amplitude difference and the IOP. The highest signal belonged to low IOP levels and it decreased with increasing IOP. The correlation of the mean acoustical signal with the given IOP showed a highly significant correlation coefficient (r=−0.98). As a result, the measured oscillation parameters are strongly dependent on the exerted IOPs. Conclusions The experiments verified the presumed relation between the acoustic oscillation of the eye and the IOP. Nevertheless, further developments are necessary for converting the oscillation parameters into reliable IOP values, to construct a tonometry device for clinical trials.

1 July 2001 in Der Ophthalmologe
Verified
Journal Article
Closed access
PDF file
GPG. Picht
G. Picht
YMY. Mutsch
Y. Mutsch
FGF. Grehn
F. Grehn

5 October 2021 in BMJ Open
Verified
Journal Article
Open access
PDF file
NPNina Pirlich
Nina Pirlich
FGFranz Grehn
Franz Grehn
KMKatja Mohnke
Katja Mohnke
KMKonrad Maucher
Konrad Maucher
ASAlexander K. Schuster
Alexander K. Schuster
Esther M.  HoffmannEsther M. Hoffmann
Esther M. Hoffmann
Introduction Neonates and young infants with diagnosed or highly suspected glaucoma require an examination under anaesthesia to achieve accurate intraocular pressure (IOP) measurements, since crying or squinting of the eyes may increase IOP and lead to falsely high values. IOP considerably depends on perioperative variables such as haemodynamic factors, anaesthetics, depth of anaesthesia and airway management. The aim of this paper is to report the design and baseline characteristics of EyeBIS, which is a study to develop a standardised anaesthetic protocol for the measurement of IOP under anaesthesia in childhood glaucoma, by investigating the link between the magnitude of IOP and depth of anaesthesia. Methods and analysis This is a single-centre, prospective cohort study in 100 children with diagnosed or highly suspected glaucoma all undergoing ophthalmological examination under general anaesthesia. 20 children, who undergo general anaesthesia for other reasons, are included as controls. The primary outcome measure is the establishment of a standardised anaesthetic protocol for IOP measurement in childhood glaucoma by assessing the relationship between IOP and depth of anaesthesia (calculated as an electroencephalography variable, the bispectral index), with special emphasis on airway management and haemodynamic parameters. The dependence of IOP under anaesthesia on airway management and haemodynamic parameters will be described, using a mixed linear model. Restricting the model to patients with healthy eyes will allow to determine a 95% reference region, in which 95% of the measurement values of patients with healthy eyes can be expected. Ethics and dissemination The study has been approved by the local ethics committee of the Medical Association of Rhineland-Palatine (Ethik-Kommisssion der Landesaerztekammer Rheinland-Pfalz), Germany (approval number: 2019-14207). This work will be disseminated by publication of peer-reviewed manuscripts, presentation in abstract form at national and international scientific meetings and data sharing with other investigators. Trial registration number ClinicalTrials.gov Registry (NCT03972852).

4 June 2021 in F1000Research
Verified
Journal Article
Open access
PDF file
ASAlicja Strzalkowska
Alicja Strzalkowska
PSPiotr Strzalkowski
Piotr Strzalkowski
YYYousef Al Yousef
Yousef Al Yousef
JHJost Hillenkamp
Jost Hillenkamp
FGFranz Grehn
Franz Grehn
NLNils Loewen
Nils Loewen
Background: To compare two-year results of a filtering trabeculotomy (FTO) to conventional trabeculectomy (TE) in open-angle glaucoma by exact matching. Methods: 110 patients received an FTO and 86 a TE. FTO avoided the need for an iridectomy due to a preserved trabeculo-descemet window anterior to the scleral flap. TE employed a trabecular block excision and iridectomy. Mitomycin C was used in both. FTO and TE were exact matched by baseline intraocular pressure (IOP) and the number of glaucoma medications. Complete and qualified success (IOP ≤18 mmHg and IOP reduction ≥ 30%, with or without medication) were primary endpoints. IOP, visual acuity (BCVA), complications and intervention were secondary endpoints. Results: 44 FTO were exact matched to 44 TE. The IOP baseline in both groups was 22.5±4.7 mmHg on 3±0.9 medications. At 24 months, complete success was reached by 59% in FTO and 66% in TE, and qualified success by 59% in FTO and 71% in TE. In FTO, IOP was reduced to 12.4±4.3 mmHg at 12 months and 13.1±4.1 mmHg at 24 months. In TE, IOP was 11.3±2.2 mmHg at 12 months and 12.0±3.5 mmHg at 24 months. Medications could be reduced at 24 months to 0.6±1.3 in FTO and 0.2±0.5 in TE. There were no significant differences between the two groups in IOP, medications, complications or interventions at any point. Conclusion: Modifying aqueous flow through a limited trabeculotomy in FTO yielded clinical outcomes similar to traditional TE but allowed to avoid an iridectomy.

30 September 2020 in OphthaTherapy. Therapies in Ophthalmology
Verified
Journal Article
Open access
PDF file
FGFranz Grehn
Franz Grehn
EHEsther Hoffmann
Esther Hoffmann
The primary therapy of all forms of primary and secondary congenital glaucoma is surgical. In the last few decades, the options for customized surgical approach to different types of childhood glaucoma have significantly developed. In particular, circumferential trabeculotomy has shown some superiority over conventional trabeculotomy and is now also used to treat secondary congenital glaucoma. Goniotomy is still a valid alternative. Tube implants in childhood glaucoma still need improvements.

1 January 2012
Verified
Book Chapter
Closed access
PDF file
FGFranz Grehn
Franz Grehn