This research aimed to design and construct an electric wheelchair with mecanum wheels that can move in any desired direction and speed based on the joystick controller. This represents a significant improvement over traditional electric wheelchairs, which are limited to linear movement in a single direction. The research contribution of this study is the development of an electric wheelchair with mecanum wheels that allows for improved mobility and independence for wheelchair users. The design includes a joystick controller and the use of an average filter to improve the processing of the joystick. This represents a significant improvement over traditional electric wheelchairs, which are limited to linear movement in a single direction. The design and construction of the electric wheelchair followed the ISO 2570-2555 guidelines and utilized Arduino DUE as the main processor for controlling the rotation of the wheels. The gain of speed and angle of the analog joystick were determined using the technique of finding the resultant vector to control the direction and speed of the wheels. The resulting electric wheelchair had a standard structure and was able to move in the desired direction and speed based on the movement of the joystick controller, demonstrating the success of the design and construction in achieving its objective. In conclusion, the development of joystick control for electric wheelchairs is important and allows for the creation of significantly novel and improved designs such as the electric wheelchair with mecanum wheels presented in this research.
This research proposes an algorithm to preprocess photoplethysmography (PPG) and electrocardiogram (ECG) signals and apply the processed signals to the context aggregation network-based deep learning to achieve higher accuracy of continuous systolic and diastolic blood pressure monitoring than other reported algorithms. The preprocessing method consists of the following steps: (1) acquiring the PPG and ECG signals for a two second window at a sampling rate of 125 Hz; (2) separating the signals into an array of 250 data points corresponding to a 2 s data window; (3) randomizing the amplitude of the PPG and ECG signals by multiplying the 2 s frames by a random amplitude constant to ensure that the neural network can only learn from the frequency information accommodating the signal fluctuation due to instrument attachment and installation; (4) Fourier transforming the windowed PPG and ECG signals obtaining both amplitude and phase data; (5) normalizing both the amplitude and the phase of PPG and ECG signals using z-score normalization; and (6) training the neural network using four input channels (the amplitude and the phase of PPG and the amplitude and the phase of ECG), and arterial blood pressure signal in time-domain as the label for supervised learning. As a result, the network can achieve a high continuous blood pressure monitoring accuracy, with the systolic blood pressure root mean square error of 7 mmHg and the diastolic root mean square error of 6 mmHg. These values are within the error range reported in the literature. Note that other methods rely only on mathematical models for the systolic and diastolic values, whereas the proposed method can predict the continuous signal without degrading the measurement performance and relying on a mathematical model.
This paper presents the development of a hybrid feature—dorsal hand vein and dorsal geometry—modality for human recognition. Our proposed hybrid feature extraction method exploits two types of features: dorsal hand geometric-related and local vein pattern. Using geometric affine invariants, the peg-free system extracts minutia points and vein termination and bifurcation and constructs a set of geometric invariants, which are then used to establish the correspondence between two sets of minutiae—one for the query vein image and the other for the reference vein image. When the correspondence is established, geometric transformation parameters are computed to align the query with the reference image. Once aligned, hybrid features are extracted for identification. In this study, the algorithm was tested on a database of 140 subjects, in which ten different dorsal hand geometric-related images were taken for each individual, and yielded the promising results. In this regard, we have achieved an equal error rate (EER) of 0.243%, indicating that our method is feasible and effective for dorsal vein recognition with high accuracy. This hierarchical scheme significantly improves the performance of personal verification and/or identification.
10 September 2023 in International Journal of Robotics and Control Systems
This study examines the effectiveness of four different fuzzy logic controllers in self-balancing wheelchairs. The controllers under consideration are Type-1 Takagi-Sugeno-Kang (TSK) FLC, Interval Type-2 TSK FLC, Type-1 Mamdani FLC, and Interval Type-2 Mamdani FLC. A MATLAB-based simulation environment serves for the evaluation, focusing on key performance indicators like percentage overshoot, rise time, settling time, and displacement. Two testing methodologies were designed to simulate both ideal conditions and real-world hardware limitations. The simulations reveal distinct advantages for each controller type. For example, Type-1 TSK excels in minimizing overshoot but requires higher force. Interval Type-2 TSK shows the quickest settling times but needs the most force. Type-1 Mamdani has the fastest rise time with the lowest force requirement but experiences a higher percentage of overshoot. Interval Type-2 Mamdani offers balanced performance across all metrics. When a 2.7 N control input cap is imposed, Type-2 controllers prove notably more efficient in minimizing overshoot. These results offer valuable insights for future design and real-world application of self-balancing wheelchairs. Further studies are recommended for the empirical testing and refinement of these controllers, especially since the initial findings were limited to four-wheeled self-balancing robotic wheelchairs.
11 March 2023 in International Journal of Robotics and Control Systems
This study evaluates the performance of three control systems, namely the root locus method, type-1 Mamdani fuzzy logic system (FLS), and interval type-2 Mamdani FLS, in noise-free and noisy ball and beam systems. The main contribution of this study is enabling improved design and implementation of control systems in real-world applications by offering a comprehensive understanding of each control system's performance. The methodology involves conducting four tests focusing on various input types, including a 0.8-meter step input and sine wave function, and assessing the presence of noise in the system. The performance of each control system is analyzed using parameters such as rise time, setting time, and percentage overshoot, with the interval type-2 Mamdani FLS further examined by varying footprint of uncertainty values. Results from noise-free tests reveal that the root locus method has shorter rise and setting times, but a higher percentage overshoot compared to the type-1 Mamdani FLS and type-2 Mamdani FLS. In noisy environments, the type-2 Mamdani FLS with varying Footprint of Uncertainty values outperforms the type-1 Mamdani FLS with reduced rise time, setting time, and percentage overshoot. The root locus method shows a significantly higher percentage overshoot in noisy conditions compared to the other two control systems. In conclusion, the type-2 Mamdani FLS control system demonstrates superior capability under changing conditions compared to the type-1 Mamdani FLS, with its performance varying based on footprint of uncertainty values. This study highlights the importance of selecting the appropriate control system depending on specific needs and environmental factors.
17 October 2024 in International Journal of Robotics and Control Systems
In engineering, especially for robots, navigation, and biomedical uses, accurate angle estimation is absolutely crucial. Using data from the IMU6050 sensor, which combines accelerometer and gyroscope readings, this work contrasts two sensor fusion methods: the Kalman filter and the complementary filter. The aim of the research is to find the most efficient filtering method for preserving accuracy and resilience throughout several motion contexts, including low-noise (standard rotation) and high-noise (external disturbances). With an eye toward improving sensor accuracy in dynamic applications, the study contribution is a thorough investigation of filter performance under different noise levels. MATLAB quantified estimate accuracy using key metrics like root mean square error (RMSE) and mean absolute error (MAE). Under controlled noise levels, our approach included methodical error analysis of both filters. Results show that, especially under low-noise conditions, the Kalman filter beats the complementary filter in terms of lower MAE and RMSE; it also shows adaptability and robustness in high-noise environments with much fewer errors than accelerometer-only and complementary filter outputs. These results show the relevance of the Kalman filter in practical settings like robotic control, motion tracking, and possible biomedical equipment, including patient positioning systems and wheelchairs with balance control. Future studies might investigate the implementation of the Kalman filter in sophisticated systems requiring accuracy, such as telemedicine robots or autonomous navigation. This work develops sensor fusion techniques and offers understanding of consistent sensor data processing in several operating environments.