Suejit Pechprasarn

Prof. Dr. Suejit Pechprasarn


Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 September 2017 in Sensors
Verified
Journal Article
Open access
PDF file
PSPhitsini Suvarnaphaet
Phitsini Suvarnaphaet
SPSuejit Pechprasarn
Suejit Pechprasarn
The advantages conferred by the physical, optical and electrochemical properties of graphene-based nanomaterials have contributed to the current variety of ultrasensitive and selective biosensor devices. In this review, we present the points of view on the intrinsic properties of graphene and its surface engineering concerned with the transduction mechanisms in biosensing applications. We explain practical synthesis techniques along with prospective properties of the graphene-based materials, which include the pristine graphene and functionalized graphene (i.e., graphene oxide (GO), reduced graphene oxide (RGO) and graphene quantum dot (GQD). The biosensing mechanisms based on the utilization of the charge interactions with biomolecules and/or nanoparticle interactions and sensing platforms are also discussed, and the importance of surface functionalization in recent up-to-date biosensors for biological and medical applications.

8 February 2022 in Scientific Reports
Verified
Journal Article
Open access
PDF file
KTKitsada Thadson
Kitsada Thadson
SSSuvicha Sasivimolkul
Suvicha Sasivimolkul
PSPhitsini Suvarnaphaet
Phitsini Suvarnaphaet
SVSarinporn Visitsattapongse
Sarinporn Visitsattapongse
SPSuejit Pechprasarn
Suejit Pechprasarn
Angular scanning-based surface plasmon resonance measurement has been utilized in label-free sensing applications. However, the measurement accuracy and precision of the surface plasmon resonance measurements rely on an accurate measurement of the plasmonic angle. Several methods have been proposed and reported in the literature to measure the plasmonic angle, including polynomial curve fitting, image processing, and image averaging. For intensity detection, the precision limit of the SPR is around 10–5 RIU to 10–6 RIU. Here, we propose a deep learning-based method to locate the plasmonic angle to enhance plasmonic angle detection without needing sophisticated post-processing, optical instrumentation, and polynomial curve fitting methods. The proposed deep learning has been developed based on a simple convolutional neural network architecture and trained using simulated reflectance spectra with shot noise and speckle noise added to generalize the training dataset. The proposed network has been validated in an experimental setup measuring air and nitrogen gas refractive indices at different concentrations. The measurement precision recovered from the experimental reflectance images is 4.23 × 10–6 RIU for the proposed artificial intelligence-based method compared to 7.03 × 10–6 RIU for the cubic polynomial curve fitting and 5.59 × 10–6 RIU for 2-dimensional contour fitting using Horner's method.

14 September 2021 in Sensors
Verified
Journal Article
Open access
PDF file
TTTreesukon Treebupachatsakul
Treesukon Treebupachatsakul
SSSiratchakrit Shinnakerdchoke
Siratchakrit Shinnakerdchoke
SPSuejit Pechprasarn
Suejit Pechprasarn
This paper provides a theoretical framework to analyze and quantify roughness effects on sensing performance parameters of surface plasmon resonance measurements. Rigorous coupled-wave analysis and the Monte Carlo method were applied to compute plasmonic reflectance spectra for different surface roughness profiles. The rough surfaces were generated using the low pass frequency filtering method. Different coating and surface treatments and their reported root-mean-square roughness in the literature were extracted and investigated in this study to calculate the refractive index sensing performance parameters, including sensitivity, full width at half maximum, plasmonic dip intensity, plasmonic dip position, and figure of merit. Here, we propose a figure-of-merit equation considering optical intensity contrast and signal-to-noise ratio. The proposed figure-of-merit equation could predict a similar refractive index sensing performance compared to experimental results reported in the literature. The surface roughness height strongly affected all the performance parameters, resulting in a degraded figure of merit for surface plasmon resonance measurement.

13 September 2017 in Sensors
Verified
Journal Article
Open access
PDF file
WPWeeratouch Pongruengkiat
Weeratouch Pongruengkiat
SPSuejit Pechprasarn
Suejit Pechprasarn
Optical resonators are sensors well known for their high sensitivity and fast response time. These sensors have a wide range of applications, including in the biomedical fields, and cancer detection is one such promising application. Sensor diagnosis currently has many limitations, such as being expensive, highly invasive, and time-consuming. New developments are welcomed to overcome these limitations. Optical resonators have high sensitivity, which enable medical testing to detect disease in the early stage. Herein, we describe the principle of whispering-gallery mode and ring optical resonators. We also add to the knowledge of cancer biomarker diagnosis, where we discuss the application of optical resonators for specific biomarkers. Lastly, we discuss advancements in optical resonators for detecting cancer in terms of their ability to detect small amounts of cancer biomarkers.

11 August 2021 in Scientific Reports
Verified
Journal Article
Open access
PDF file
KTKitsada Thadson
Kitsada Thadson
SVSarinporn Visitsattapongse
Sarinporn Visitsattapongse
SPSuejit Pechprasarn
Suejit Pechprasarn
A deep learning algorithm for single-shot phase retrieval under a conventional microscope is proposed and investigated. The algorithm has been developed using the context aggregation network architecture; it requires a single input grayscale image to predict an output phase profile through deep learning-based pattern recognition. Surface plasmon resonance imaging has been employed as an example to demonstrate the capability of the deep learning-based method. The phase profiles of the surface plasmon resonance phenomena have been very well established and cover ranges of phase transitions from 0 to 2π rad. We demonstrate that deep learning can be developed and trained using simulated data. Experimental validation and a theoretical framework to characterize and quantify the performance of the deep learning-based phase retrieval method are reported. The proposed deep learning-based phase retrieval performance was verified through the shot noise model and Monte Carlo simulations. Refractive index sensing performance comparing the proposed deep learning algorithm and conventional surface plasmon resonance measurements are also discussed. Although the proposed phase retrieval-based algorithm cannot achieve a typical detection limit of 10–7 to 10–8 RIU for phase measurement in surface plasmon interferometer, the proposed artificial-intelligence-based approach can provide at least three times lower detection limit of 4.67 × 10–6 RIU compared to conventional intensity measurement methods of 1.73 × 10–5 RIU for the optical energy of 2500 pJ with no need for sophisticated optical interferometer instrumentation.

4 July 2014 in Light: Science & Applications
Verified
Journal Article
Open access
SPSuejit Pechprasarn
Suejit Pechprasarn
BZBei Zhang
Bei Zhang
DADarren Albutt
Darren Albutt
JZJing Zhang
Jing Zhang
MSmike somekh
mike somekh
As disease diagnosis becomes more sophisticated, there is a requirement to measure small numbers of molecules attached to, for instance, an antibody. This requires a sensor capable not only of high sensitivity but also the ability to make measurements over a highly localized region. In previous publications, we have shown how a modified confocal microscope allows one to make localized surface plasmon (SP) measurements on a scale far smaller than the surface plasmon propagation distance. The present implementation presents a new ultrastable interferometer system, which greatly improves the noise performance. Hitherto, we have used the central part of the back focal plane to form a reference beam with the reradiated surface plasmons. In the current system, we block the central part and use the spatial light modulator to deflect s-polarized light into the pinhole to form an interference signal with the surface plasmons, thus creating an ultrastable interferometer formed with two beams incident at very similar angles. We demonstrate the superior noise performance of the system in hostile environments and examine further adaptations of the system to further enhance noise performance.