This study focuses on the automatic generation control (AGC) system, which is crucial for maintaining balance between power generation and demand in power systems. The implementation of the AGC system needs to be more precise due to the increasing uncertainty surrounding renewable energy sources (RESs) and changes in demand. The objective of this study is to investigate the AGC functions in a two-area hybrid power system that combines a PV system with a reheat thermal system. To improve system performance, we utilize a proportional-integral (PI) controller. We utilized a recently developed optimization method, RIME, for tuning controller parameters. This technique has not been studied before in AGC processes. Furthermore, the optimization procedure utilizes a modified version of the integral time-multiplied absolute error (ITAE) objective function. The study compares the performance of the RIME-tuned PI controller under various scenarios, including changes in thermal system load, load variations in both areas, and robustness considerations, with well-known techniques in the literature, such as black widow optimization algorithm (BWOA), salp swarm algorithm (SSA), shuffled frog leaping algorithm (SFLA), firefly algorithm (FA) and genetic algorithm (GA). Our comparative study demonstrates that the proposed controller outperforms state-of-the-art approaches in terms of overshoot values and damping durations for both system frequency and tie-line power changes. The study provides valuable information on the effectiveness of the RIME-tuned PI controller in controlling AGC processes in complex hybrid power systems.
The frequency value should be kept constant to ensure and maintain synchronization in power systems. When the balance between generation and load is interrupted, the frequency value increases or decreases. This frequency deviation may lead to serious problems in the power system. Therefore, a design of a controller is required to keep the system frequency and tie-line power variations within specified limits, which is called automatic generation control (AGC) or load frequency control (LFC). This paper aims to determine the optimal controller parameters used in the LFC for a two-area non-reheat thermal power system integrated with various renewable energy sources (RES) such as photovoltaic (PV) and wind energy systems. The proposed controller is a PI–(1 + DD) controller which is a combination of proportional, integral, and double derivative controllers. The optimal gains of the proposed controller are determined by the Grey Wolf Optimization (GWO) algorithm. Moreover, the performance of the PI–(1 + DD) controller is tested under various scenarios such as different step load perturbations, random load changes, system parameters and RES variation. The results show that the PI–(1 + DD) controller provides an improvement of about 40% in system frequency overshoot and about 45% in settling time compared to other controllers.
1 February 2024 in International Journal of Dynamics and Control