Xiaolong Yang

Prof. Xiaolong Yang

Guangxi University of Science and Technology

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2016 in International Journal of Applied Electromagnetics and Mechanics
Verified
Journal Article
Closed access
PDF file
XYXiaolong Yang
Xiaolong Yang
DLDe Cai Li
De Cai Li
To improve the pressure capacity of the magnetic fluid seal with a large sealing gap, a new type of stepped magnetic fluid seals was firstly proposed based on magnetic fluid seal with multiple magnetic sources or stepped labyrinth seals. A universal magnetic fluid seal with two permanent magnets and a diverging stepped magnetic fluid seal have been investigated by experimental methods. The experimental results of the both sealing structures have been compared and analyzed. The results indicate that the diverging stepped magnetic fluid seal shows good performance compared to the universal magnetic fluid seal without stepping structure and it is an effective method to improve magnetic fluid sealing capacity with a large gap.

1 March 2024 in Physics of Fluids
Verified
Journal Article
Closed access
PDF file
XYXiaolong Yang
Xiaolong Yang
XDXuankai Dou
Xuankai Dou
YLYang Liu
Yang Liu
GXGuojin Xie
Guojin Xie
To investigate the influence of temperature on the pressure transfer mechanism and failure mechanism for magnetic fluid seal (MFS) with opposite pole teeth (OPT), a sealing device with water circulation channel was designed. Sealing mechanism and performance of the sealing device at different temperatures were experimentally investigated under gas and vacuum environments, respectively, and comparison with the experimental results at normal temperature. Theoretical pressure resistance was calculated according to the theoretical pressure resistance formula for MFS with temperature coefficient. The results show that temperature affects the trend of pressure difference variation for the MFS-OPT. As temperature decreases, self-stability of the magnetic fluid film improves, while pressure resistance and self-healing capability of the MFS-OPT become more pronounced.

28 January 2019 in IEEE Transactions on Magnetics
Verified
Journal Article
Closed access
XYXiaolong Yang
Xiaolong Yang
PSPeng Sun
Peng Sun
FCFan Chen
Fan Chen
FHFuxiang Hao
Fuxiang Hao
DLDecai Li
Decai Li
PTPeter J. Thomas
Peter J. Thomas
To improve the pressure capability of ordinary ferrofluid seals with a large gap, a novel type of converging stepped ferrofluid seals was proposed. The leakage positions and the magnetic field distributions in the sealing gaps of the new device are studied computationally by means of the finite-element method. The theoretical pressure capabilities of the seal are calculated based on a new expression introduced for the particular new seal geometry and for different sealing gaps. Computational results for effects of the radial and axial sealing gaps on the pressure capabilities of the seal are compared to the experimental results obtained from measurements employing a prototype of the proposed new seal. A good agreement between theoretical and experimental results is obtained. It is found that the pressure capabilities of the new seal depend on the height of the radial sealing gap and on the width of the axial sealing gap.

23 June 2022 in Tribology Transactions
Verified
Journal Article
Closed access
YGYing Guan
Ying Guan
XYXiaolong Yang
Xiaolong Yang
Although the sealing mechanism of the embedded magnetic fluid seal is unclear, it is an effective way to improve the performance of the ordinary magnetic fluid seal. Embedded magnetic seals can be divided into diverging and converging embedded magnetic fluid seals, according to the direction of leakage of the sealed medium. This article mainly focuses on presenting a sealing device that can observe the change in the shape of the magnetic fluid film and investigate the mechanism of diverging and converging embedded magnetic fluid seals. The pressure transfer mechanism of the embedded magnetic fluid seal with a large gap was studied through experiments. Numerical analysis of the magnetic field distribution in the seal gap and calculation of the theoretical pressure capacity of the embedded magnetic fluid seal are produced on the basis of embedded magnetic fluid seal theory. The experimental pressure capacity is compared with the theoretical pressure capacity to verify the correctness of the embedded magnetic fluid seal pressure capacity theory. The research has investigated the effect of the number of magnetic fluid film ruptures on the self-restoring capacity of embedded magnetic fluid seals, compared with the self-restoring capacity of diverging and converging embedded magnetic fluid seals, and analyzed the data. The results illustrated that the experimental pressure capacity of the embedded magnetic fluid seal matched well with the theoretical pressure capacity, which verifies the correctness of the embedded magnetic fluid seal theory. The pressure transfers from one chamber to another when the pressure difference between the two sides of the magnetic fluid film under the pole tooth is larger than the pressure capacity of the magnetic fluid seal, and the air will enter from the high-pressure side seal chamber to the low-pressure side seal chamber, in turn. As the inlet pressure increases, the pressure trend in the radial chamber of the embedded magnetic fluid seal differs from that in the axial chamber. When the seal fails, the magnetic fluid shows microleakage and complete leakage. As the number of magnetic fluid film ruptures increases, the self-restoring capacity first decreases and then increases. The self-restoring capacity of the converging embedded magnetic fluid seals is better than that of the diverging embedded magnetic fluid seals.

1 February 2025 in Physics of Fluids
Verified
Journal Article
Closed access
XYXiaolong Yang
Xiaolong Yang
XLXue Li
Xue Li
JZJiehong Zhu
Jiehong Zhu
DLDenghui Li
Denghui Li
To enhance the mechanical properties of built-in valve-type magnetorheological dampers, a new magnetorheological fluid (abbreviated as HCMN-MRF) prepared using hydroxylated carbon nanotubes (HCNT)-coated micrometer-sized carbonyl iron particles (CIPs) mixed with nano-sized iron particles (NIPs) was investigated in this study. In order to assess the properties of the coated CIPs and the new MRFs, they were characterized morphologically and tested for performance. Under identical conditions, the HCNT-MRF and the commercial MRF were utilized in a built-in valve-type magnetorheological damper to conduct damping experiments, respectively. The outcomes of both MRF applications were meticulously compared and analyzed to evaluate their performance. It was found that the HCNT-coated CIPs exhibited a high saturation magnetization strength of 218 emu/g, and the new MRFs containing NIPs all have a sedimentation ratio of less than 25%. In addition, by applying the new MRF and the commercial MRF to the damper, the damper using the new MRF achieves a maximum damping force of 1505 N, which is significantly higher than the maximum damping force of 1005 N produced by the commercial MRF in the same damper, and for currents less than 2 A, the adjustable coefficients obtained with the new MRF are greater than those obtained with the commercial MRF, with a maximum adjustable coefficient of 3.2.

19 December 2023 in Vacuum
Verified
Journal Article
Closed access
XYXiaolong Yang
Xiaolong Yang
XZXinyue Zhu
Xinyue Zhu
YLYang Lei
Yang Lei
YHYinyan Huang
Yinyan Huang