CAMELIA ALBU

Dr. CAMELIA ALBU

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 April 2019 in Prenatal Diagnosis
Verified
Journal Article
Open access
PDF file
ASAdelina Staicu
Adelina Staicu
CACAMELIA ALBU
CAMELIA ALBU
RPRoxana Popa‐Stanila
Roxana Popa‐Stanila
LCLiviu Chiriac
Liviu Chiriac
DBDan Boitor-Borza
Dan Boitor-Borza
FSFlorin Stamatian
Florin Stamatian
Objective: The aim of this study was to establish the diagnostic accuracy of high‐field magnetic resonance imaging (MRI) at 7 Tesla (T) compared with that of stereomicroscopic autopsy for assessing first trimester fetuses.Methods: Nine consecutive cases of first trimester fetuses resulting from spontaneous and therapeutic pregnancy termination were considered. The cases were divided into two groups according to gestational age: the Embryo Group with cases of nine to 10 gestational weeks (GWs) and the Fetus Group with cases of 13 GWs. The first group was scanned using three‐dimensional fast imaging with steady state precession (3D FISP), and the second group was scanned using a two‐dimensional (2D) turbo spin‐echo high‐resolution T2‐weighted imaging (T2 WI) protocol. A radiologist and two embryologists interpreted the images. All cases were evaluated by invasive autopsy, with pathologist blinded to the imaging results. In total, the database included 270 items for evaluation (9 cases × 30 structures/case).Results: The global agreement between fetal high‐field virtopsy and microscopic or stereomicroscopic autopsy was evaluated using 225 evaluation items visible by both methods. Overall, using microscopic examination and stereomicroscopic autopsy as the gold standard, fetal high‐field virtopsy had a sensitivity of 94.6% [95% CI, 87.2‐98.3] and a specificity of 97.6% [95% CI, 95‐98.8]. The positive predictive value (PPV) was 93% [95% CI, 85.7‐96.6], and the negative predictive value (NPV) was 98.2% [95% CI, 95.7‐99.4]. Cohen kappa coefficient of agreement was k = 0.92 [95% CI, 0.82‐0.97], and the McNemar test showed p = 1.00.Conclusions: Virtual autopsy using high‐field MRI at 7 T can be considered a safe alternative approach to stereomicroscopic autopsy for the assessment of fetal structural anomalies at the end of the first trimester of pregnancy.

1 July 2020 in International Journal of Nanomedicine
Verified
Journal Article
Open access
PDF file
SIStefania D Iancu
Stefania D Iancu
CACAMELIA ALBU
CAMELIA ALBU
LCLiviu Chiriac
Liviu Chiriac
RMRemus Moldovan
Remus Moldovan
ASAndrei Stefancu
Andrei Stefancu
ZBZoltán Bálint
Zoltán Bálint
Purpose: Magnetic resonance imaging (MRI) contrast agents are pharmaceuticals that enable a better visualization of internal body structures. In this study, we present the synthesis, MRI signal enhancement capabilities, in vitro as well as in vivo cytotoxicity results of gold-coated iron oxide nanoparticles (Fe3O4@AuNPs) as potential contrast agents. Methods: Fe3O4@AuNPs were obtained by synthesizing iron oxide nanoparticles and gradually coating them with gold. The obtained Fe3O4@AuNPs were characterized by spectroscopies, transmission electron microscopy (TEM) and energy dispersive X-ray diffraction. The effect of the nanoparticles on the MRI signal was tested using a 7T Bruker PharmaScan system. Cytotoxicity tests were made in vitro on Fe3O4@AuNP-treated retinal pigment epithelium cells by WST-1 tests and in vivo by following histopathological changes in rats after injection of Fe3O4@AuNPs. Results: Stable Fe3O4@AuNPs were successfully prepared following a simple and fast protocol (< 1h worktime) and identified using TEM. The cytotoxicity tests on cells have shown biocompatibility of Fe3O4@AuNPs at small concentrations of Fe (< 1.95× 10− 8 mg/cell). Whereas, at higher Fe concentrations (eg 7.5× 10− 8 mg/cell), cell viability decreased to 80.88± 5.03%, showing a mild cytotoxic effect. MRI tests on rats showed an optimal Fe3O4@AuNPs concentration of 6mg/100g body weight to obtain high-quality images. The histopathological studies revealed significant transient inflammatory responses in the time range from 2 hours to 14 days after injection and focal cellular alterations in several organs, with the lung being the most affected organ. These results were confirmed by hyperspectral microscopic imaging of the same, but unstained tissues. In most organs, the inflammatory responses and sublethal cellular damage appeared to be transitory, except for the kidneys, where the glomerular damage indicated progression towards glomerular sclerosis. Conclusion: The obtained stable, gold covered, iron oxide nanoparticles with reduced cytotoxicity, gave a negative T2 signal in the MRI, which makes them suitable for candidates as contrast agent in small animal MRI applications.

17 January 2022 in Diagnostics
Verified
Journal Article
Open access
PDF file
CACAMELIA ALBU
CAMELIA ALBU
ASAdelina Staicu
Adelina Staicu
RPRoxana Popa-Stanilă
Roxana Popa-Stanilă
CBCosmina Ioana Bondor
Cosmina Ioana Bondor
BPBogdan Pop
Bogdan Pop
FSFlorin Stamatian
Florin Stamatian
The examination of very small fetal hearts requires special equipment and a specialist that are not available in many general pathology laboratories. Compared to conventional examination, the four-chamber cardiac dissection (4CCD) method can be performed by any pathologist using instruments generally available in pathology services. The aim of this study is to evaluate the efficiency of the 4CCD method in the examination of small fetal hearts using post-mortem magnetic resonance imaging (pm-MRI) at 7T as the standard. Twelve fetuses with gestational ages between 13 and 19 weeks have been included in this study. All fetuses underwent pm-MRI examination prior to pathologic examination. The 4CCD method was used for the cardiac examination in all cases following the same guidelines for cardiac sectioning. The 4CCD was able to identify all cardiac anatomic structures as compared to pm-MRI at 7T, demonstrating a sensibility of 95.8% (95% CI, 94.5–95.8) and specificity of 100% (95% CI, 32.3–100). The overall accuracy in identifying cardiac anatomic structures was 95.8% (95% CI, 93.4–95.8). Additionally, the 4CCD method was able to detect cardiac anomalies with an overall diagnostic accuracy of 91% (95% CI, 85.8–94.2), sensibility of 67.6% (95% CI, 54.5–75.3), and specificity of 97% (95% CI, 93.7–99) as compared to pm-MRI at 7T. The four-chamber view dissection method can be considered as an alternative to the conventional inflow–outflow dissection method in selected cases.

1 January 2018
Verified
Journal Article
Closed access
CACAMELIA ALBU
CAMELIA ALBU
ASAdelina Staicu
Adelina Staicu
RPRoxana Tania Popa-Stanila
Roxana Tania Popa-Stanila
AMAlina Camelia Milas
Alina Camelia Milas
LCLiviu Bogdan Chiriac
Liviu Bogdan Chiriac
VSVasile Florin Stamatian
Vasile Florin Stamatian

30 August 2018 in Medical Ultrasonography
Verified
Journal Article
Closed access
PDF file
DCDelia Clinciu
Delia Clinciu
MDMarina Dudea-Simon
Marina Dudea-Simon
CACAMELIA ALBU
CAMELIA ALBU
RCrazvan ciortea
razvan ciortea
DDDoru Constantin Mihai Diculescu
Doru Constantin Mihai Diculescu
DMDan Mihu
Dan Mihu
Twin reversed arterial perfusion (TRAP) sequence is a rare and severe complication specific to monochorionic twin pregnancies, involving the presence of an acardiac twin and a structurally normal co-twin (pump twin). We report on the case of a33-year-old female with a biamniotic monochorionic twin pregnancy complicated with TRAP sequence and polyhydramnios. The patient underwent fetoscopic termination of the acardiac twin and at 34 gestational weeks (GW) was readmitted with a retroplacental hematoma. The patient gave birth through caesarean section to a living female fetus, weighing 1480 g. To the best of our knowledge, this is the first case reporting a twin pregnancy with TRAP sequence complicated with retroplacental hematoma.

22 March 2023 in Diagnostics
Verified
Journal Article
Open access
PDF file
ASAdelina Staicu
Adelina Staicu
CACAMELIA ALBU
CAMELIA ALBU
GNGeorgiana Nemeti
Georgiana Nemeti
CBCosmina Ioana Bondor
Cosmina Ioana Bondor
DBDan Boitor-Borza
Dan Boitor-Borza
DMDaniel Muresan
Daniel Muresan
Introduction: This research aims to describe a progressive pattern of ultrasound placental remodeling in patients with a history of SARS-CoV-2 infection during pregnancy. Materials and Methods: This was a longitudinal, cohort study which enrolled 23 pregnant women with a history of former mild SARS-CoV-2 infection during the current pregnancy. Four obstetricians analyzed placental ultrasound images from different gestational ages following COVID infection and identified the presence and degree of remodeling. We assessed the inter-rater agreement and the interclass correlation coefficients. Pathology workup included placental biometry, macroscopic and microscopic examination. Results: Serial ultrasound evaluation of the placental morphology revealed a progressive pattern of placental remodeling starting from 30–32 weeks of gestation towards term, occurring approximately 8–10 weeks after the SARS-CoV-2 infection. Placental changes—the “starry sky” appearance and the “white line” along the basal plate—were identified in all cases. Most placentas presented normal subchorionic perivillous fibrin depositions and focal stem villi perivillous fibrin deposits. Focal calcifications were described in only 13% of the cases. Conclusions: We identified two ultrasound signs of placental remodeling as potential markers of placental viral shedding following mild SARS-CoV-2. The most likely pathology correspondence for the imaging aspect is perivillous and, respectively, massive subchorionic fibrin deposits identified in most cases.