An economical corncob biochar-based magnetic iron–copper bimetallic nanomaterial (marked as MBC) was successfully synthesized and optimized through a co-precipitation and pyrolysis method. It was successfully used to activate H2O2 to remove ciprofloxacin (CIP) from aqueous solutions. This material had high catalytic activity and structural stability. Additionally, it had good magnetic properties, which can be easily separated from solutions. In MBC/H2O2, the removal efficiency of CIP was 93.6% within 360 min at optimal reaction conditions. The conversion of total organic carbon (TOC) reached 51.0% under the same situation. The desorption experiments concluded that adsorption and catalytic oxidation accounted for 34% and 66% on the removal efficiency of CIP, respectively. The influences of several reaction parameters were systematically evaluated on the catalytic activity of MBC. OH was proved to play a significant role in the removal of CIP through electron paramagnetic resonance (EPR) analysis and a free radical quenching experiment. Additionally, such outstanding removal efficiency can be attributed to the excellent electronic conductivity of MBC, as well as the redox cycle reaction between iron and copper ions, which achieved the continuous generation of hydroxyl radicals. Integrating HPLC-MS, ion chromatography and density functional theory (DFT) calculation results, and possible degradation of the pathways of the removal of CIP were also thoroughly discussed. These results provided a theoretical basis and technical support for the removal of CIP in water.
As a key parameter in the adsorption process, removal rate is not available under most operating conditions due to the time and cost of experimental testing. To address this issue, evaluation of the efficiency of NH4+ removal from stormwater by coal-based granular activated carbon (CB-GAC), a novel approach, the response surface methodology (RSM), back-propagation artificial neural network (BP-ANN) coupled with genetic algorithm (GA), has been applied in this research. The sorption process was modeled based on Box-Behnben design (BBD) RSM method for independent variables: Contact time, initial concentration, temperature, and pH; suggesting a quadratic polynomial model with p-value < 0.001, R2 = 0.9762. The BP-ANN with a structure of 4-8-1 gave the best performance. Compared with the BBD-RSM model, the BP-ANN model indicated better prediction of the response with R2 = 0.9959. The weights derived from BP-ANN was further analyzed by Garson equation, and the results showed that the order of the variables’ effectiveness is as follow: Contact time (31.23%) > pH (24.68%) > temperature (22.93%) > initial concentration (21.16%). The process parameters were optimized via RSM optimization tools and GA. The results of validation experiments showed that the optimization results of GA-ANN are more accurate than BBD-RSM, with contact time = 899.41 min, initial concentration = 17.35 mg/L, temperature = 15 °C, pH = 6.98, NH4+ removal rate = 63.74%, and relative error = 0.87%. Furthermore, the CB-GAC has been characterized by Scanning electron microscopy (SEM), X-ray diffraction (XRD) and Brunauer-Emmett-Teller (BET). The isotherm and kinetic studies of the adsorption process illustrated that adsorption of NH4+ onto CB-GAC corresponded Langmuir isotherm and pseudo-second-order kinetic models. The calculated maximum adsorption capacity was 0.2821 mg/g.
Utility tunnel plays a critical role in concentrating various important urban engineering pipelines but faces severe fire risks and safety threats. In this study, the temperature distribution characteristics of cable fire in utility tunnel were studied by means of full-scale fire experiment, and the effects of spray intensity, cable fullness and ambient wind speed on fire extinguishing efficiency of high-pressure water mist fire extinguishing system (HWMFES) were investigated. The results show that the maximum heating area of cable fire in utility tunnel is localized to the three cable bridges nearest to and directly above the fire source, with a highest temperature exceeding 800°C, while other areas on the same side and the opposite side are negligibly affected. Increasing spray intensity significantly enhances the fire extinguishing efficiency of HWMFES. Reducing cable fullness can effectively shortens the fire extinguishing time of HWMFES. providing longitudinal ventilation of 2 m/s in utility tunnel can significantly improve the fire extinguishing efficiency of HWMFES. The results of this research can provide a theoretical foundation and data support for the engineering application of HWMFES in utility tunnels.
Utility tunnels concentrate various important urban engineering pipelines within a shared underground space, which poses significant fire risks, particularly from cable fires. In this study, a full-scale fire experiment was conducted to investigate the temperature distribution characteristics of cable fires in utility tunnels, along with the effects of spray intensity, cable fullness, and longitudinal ventilation on the extinguishing efficiency of a high-pressure water mist fire extinguishing system (HWMFES). The results show that the maximum heating area of a cable fire in a utility tunnel is localized to the three cable trays nearest to and directly above the fire source, with a peak temperature of 825 °C, while the impact on other areas is negligible. Increasing the spray intensity from 0.7 to 1.0 L/(min·m2) reduced the time required to lower temperatures to 50 °C by 40.8%, while reducing cable fullness from 12 to 6 cables per tray shortened extinguishing time by 22.5%. Additionally, applying a ventilation speed of 2 m/s enhanced cooling efficiency, reducing the time to reach 50 °C by 67.5% compared to still air conditions. These findings provide practical insights and data support for optimizing the design and application of HWMFES in enhancing fire safety in utility tunnels.