Peng Du

Mr. Peng Du


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 April 2022 in Buildings
Verified
Journal Article
Open access
PDF file
SYSha sha Yuan
Sha sha Yuan
KXKun Xiang
Kun Xiang
FYFeng Yan
Feng Yan
QLQing Liu
Qing Liu
XSXuan Sun
Xuan Sun
PDPeng Du
Peng Du
In ancient villages, the spread of uninterrupted fires caused great damage to clustered wooden houses. Thus, the spread of fire among wooden houses should be systematically studied to explore its characteristics. Statistical analysis is a feasible way to study the characteristics and underlying mechanisms of fire in full-scale wooden houses. In this study, 4 full-scale wooden buildings were built in an ethnic village in Guizhou Province, and the fire spread test was conducted by igniting a 0.63-MW power wood crib. To investigate the fire spread, the visual characteristics were observed, and the temperatures and heat radiation at special locations were monitored with thermocouples and radiation flowmeters, respectively. The effect of relative slope, heat radiation, and wind direction on fire spread characteristics was established by mathematical statistics, and the measured temperatures were used to verify the statistics’ regularity. The results showed that in wooden houses, fire spread was mainly influenced by the slope, the distance between houses, and wind direction. When the inner wall of a wooden house is protected by a fireproof coating, the thermal radiation spread and fire spread are both slower. The slope and distance had the same influence weight (0.41) on fire spread; however, since they affect the process in different ways, they should be analyzed separately for fire risk evaluation. The findings of this study provide a theoretical foundation for understanding the fire spread process in wooden buildings.

14 July 2020 in Water
Verified
Journal Article
Open access
PDF file
PDPeng Du
Peng Du
XLXing Li
Xing Li
YYYanling Yang
Yanling Yang
ZZZhiwei Zhou
Zhiwei Zhou
Xiaoyan FanXiaoyan Fan
Xiaoyan Fan
Jianyong FengJianyong Feng
Jianyong Feng
Gravity-driven membrane (GDM) ultrafiltration is a promising water treatment method due to its low energy consumption and low maintenance. However, the low stable permeability in algae-laden water treatment is currently limiting its wider application. With the ultimate goal of increasing permeability, the aim of this study was to evaluate the effect of a composite coagulant of aluminum sulfate-chitosan (AS-CS) on the GDM filtration performance. In parallel tests with a single AS coagulant and without pre-coagulation, the analysis of membrane fouling resistance and the membrane fouling mechanism were evaluated. The results indicated that the AS-CS/GDM system can alleviate 23.74% and 58.80% membrane fouling, respectively, compared with AS/GDM and the GDM system. The AS-CS/GDM system can effectively remove humic-like substances having a molecular weight (MW) of 3–100 kDa, resulting in removal of 98.32% of algae cells and removal of 66.25% of dissolved organic carbon; the AS-CS/GDM system thereby improved the concentration of attached biomass on the membrane surface with the stronger biodegradability of organic matters. The application of AS-CS pre-coagulation in the GDM process could enhance the proliferation of microorganisms and the removal of low molecular weight humic-like substances. Therefore, the AS-CS/GDM system is a potentially important approach for algae-laden water treatment.

20 April 2022 in Case Studies in Thermal Engineering
Verified
Journal Article
Open access
SYShasha Yuan
Shasha Yuan
XSXuan Sun
Xuan Sun
SLSongtao Liu
Songtao Liu
YLYinqing Li
Yinqing Li
PDPeng Du
Peng Du

21 October 2021 in Water
Verified
Journal Article
Open access
PDF file
KXKun Xiang
Kun Xiang
PGPan Geng
Pan Geng
XSXuan Sun
Xuan Sun
SYSha sha Yuan
Sha sha Yuan
PDPeng Du
Peng Du
XLXing Li
Xing Li
The biofilms generated in a fire extinguishing water supply system can cause corrosion and a reduction in the water supply capacity; thus, degrading the system performance. To mitigate microbial corrosion, appropriate disinfection measures are necessary. In this study, the secondary addition of chlorine is employed to investigate the kinetics of chlorine decay, and shock disinfection is applied to investigate the removal efficiency of corrosion bacteria, and the microbial composition of a biofilm on the pipe wall was also clarified. The results show that the residual chlorine content in the secondary chlorination process was directly correlated with the decay rate of residual chlorine and the corrosion rate of the pipe wall. Additionally, the chlorine impact disinfection method could reduce the electrochemical corrosion phenomenon of the pipe wall. When the concentration of chlorine was 3 mg/L, the removal rate of corrosion bacteria was higher in 60 min than in 30 min. Specifically, most of the bacteria were inactivated in 60 min and the biofilm was severely damaged. Shock disinfection could significantly inactivate all microflora in the biofilm; the relative abundances of microflora varied significantly, while the change of microflora at the phylum level was insignificant. This study can provide theoretical support for the secondary addition of chlorine and shock disinfection in a fire extinguishing water supply system.

3 October 2025 in Preprints.org
Verified
Preprint
Open access
PDF file
KXKun Xiang
Kun Xiang
PDPeng Du
Peng Du
HLHongrun Liu
Hongrun Liu
YFYaojia Fu
Yaojia Fu
TLTaoran Li
Taoran Li
Utility tunnel plays a critical role in concentrating various important urban engineering pipelines but faces severe fire risks and safety threats. In this study, the temperature distribution characteristics of cable fire in utility tunnel were studied by means of full-scale fire experiment, and the effects of spray intensity, cable fullness and ambient wind speed on fire extinguishing efficiency of high-pressure water mist fire extinguishing system (HWMFES) were investigated. The results show that the maximum heating area of cable fire in utility tunnel is localized to the three cable bridges nearest to and directly above the fire source, with a highest temperature exceeding 800°C, while other areas on the same side and the opposite side are negligibly affected. Increasing spray intensity significantly enhances the fire extinguishing efficiency of HWMFES. Reducing cable fullness can effectively shortens the fire extinguishing time of HWMFES. providing longitudinal ventilation of 2 m/s in utility tunnel can significantly improve the fire extinguishing efficiency of HWMFES. The results of this research can provide a theoretical foundation and data support for the engineering application of HWMFES in utility tunnels.

17 October 2025 in Fire
Verified
Journal Article
Open access
PDF file
KXKun Xiang
Kun Xiang
PDPeng Du
Peng Du
HLHongrun Liu
Hongrun Liu
YFYaojia Fu
Yaojia Fu
TLTaoran Li
Taoran Li
Utility tunnels concentrate various important urban engineering pipelines within a shared underground space, which poses significant fire risks, particularly from cable fires. In this study, a full-scale fire experiment was conducted to investigate the temperature distribution characteristics of cable fires in utility tunnels, along with the effects of spray intensity, cable fullness, and longitudinal ventilation on the extinguishing efficiency of a high-pressure water mist fire extinguishing system (HWMFES). The results show that the maximum heating area of a cable fire in a utility tunnel is localized to the three cable trays nearest to and directly above the fire source, with a peak temperature of 825 °C, while the impact on other areas is negligible. Increasing the spray intensity from 0.7 to 1.0 L/(min·m2) reduced the time required to lower temperatures to 50 °C by 40.8%, while reducing cable fullness from 12 to 6 cables per tray shortened extinguishing time by 22.5%. Additionally, applying a ventilation speed of 2 m/s enhanced cooling efficiency, reducing the time to reach 50 °C by 67.5% compared to still air conditions. These findings provide practical insights and data support for optimizing the design and application of HWMFES in enhancing fire safety in utility tunnels.