Matteo Gavazzoni

Mr. Matteo Gavazzoni

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

11 October 2021 in Fatigue & Fracture of Engineering Materials & Structures
Verified
Journal Article
Open access
PDF file
MGMatteo Gavazzoni
Matteo Gavazzoni
MPMarco Pisati
Marco Pisati
Stefano BerettaStefano Beretta
Stefano Beretta
Stefano FolettiStefano Foletti
Stefano Foletti
This paper focuses on numerical the prediction of multiaxial static strength of lattice structures. We analyze a body‐centered cubic cell printed with Selective Laser Melting in AlSi10Mg aluminum alloy. Parent material is experimentally characterized, and the Gurson‐Tveergard‐Needleman (GTN) damage model is calibrated to predict failure in numerical simulations. The GTN model is used to predict failure of the lattice structures exhibiting brittle localized fracture, and it is validated through static tests. The results of experimental tension/compression monotonic tests on lattice samples are compared with the results of numerical simulations performed on as‐built geometry reconstructed by X‐ray computed tomography, showing a good correlation. Combining the damage model with computational micromechanics, multiaxial loading conditions are simulated to investigate the effective multiaxial strength of the lattice material. Yielding and failure loci are found by fitting a batch of points obtained by some multiaxial loading simulations. A formulation based on the criterion proposed by Tsai and Wu (1971) for anisotropic materials provides a good description of yielding and failure behavior under multiaxial load. Results are discussed, with a specific focus on the effect of as‐built defects on multiaxial strength, by comparing the resistance domains of as‐manufactured and as‐designed lattices.


Verified
Journal Article
Open access
PDF file
MGMatteo Gavazzoni
Matteo Gavazzoni
NFNicola Ferro
Nicola Ferro
Simona PerottoSimona Perotto
Simona Perotto
Stefano FolettiStefano Foletti
Stefano Foletti
We present a new algorithm to design lightweight cellular materials with required properties in a multi-physics context. In particular, we focus on a thermo-elastic setting by promoting the design of unit cells characterized both by an isotropic and an anisotropic behavior with respect to mechanical and thermal requirements. The proposed procedure generalizes the microSIMPATY algorithm to a thermo-elastic framework by preserving all the good properties of the reference design methodology. The resulting layouts exhibit non-standard topologies and are characterized by very sharp contours, thus limiting the post-processing before manufacturing. The new cellular materials are compared with the state-of-art in engineering practice in terms of thermo-elastic properties, thus highlighting the good performance of the new layouts which, in some cases, outperform the consolidated choices.

23 April 2026 in Designs
Verified
Journal Article
Open access
PDF file
RCRoberta Cromi
Roberta Cromi
BFBerti Francesca
Berti Francesca
MGMatteo Gavazzoni
Matteo Gavazzoni
LBLuigi La Barbera
Luigi La Barbera
DPDalila Di Palma
Dalila Di Palma
TVTomaso Villa
Tomaso Villa
Bone resorption secondary to stress shielding is a leading cause of hip implant failure, primarily due to the stiffness mismatch between the femur and the prosthesis. Although anatomical stem designs generally provide improved load transfer, Dorr type C femurs often require straight stems to ensure adequate primary stability. This work presents a systematic approach to designing a straight, additively manufactured porous titanium hip stem aimed at minimizing stress shielding. The lattice architecture is customized to replicate the mechanical properties of bone based on patient-specific femoral CT scans. The performance of the resulting porous implant is numerically assessed under simplified physiological gait loading conditions. The implant behavior is evaluated through a homogenization strategy to model the lattice structure, significantly reducing the computational effort and making the methodology easily replicable. Compared to its full counterpart, the porous design achieves a significant reduction in predicted bone loss, suggesting that the proposed framework is a promising proof of concept for patient-specific implants. While further experimental validation and larger cohort studies are required, these findings highlight the potential of mechanically tunable porous structures to mitigate the stress shielding phenomenon in anatomical conditions such as Dorr type C femurs, which require straight stems.