Roberta Cromi

Ms. Roberta Cromi

orcid

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 April 2026 in Designs
Verified
Journal Article
Open access
PDF file
RCRoberta Cromi
Roberta Cromi
BFBerti Francesca
Berti Francesca
MGMatteo Gavazzoni
Matteo Gavazzoni
LBLuigi La Barbera
Luigi La Barbera
DPDalila Di Palma
Dalila Di Palma
TVTomaso Villa
Tomaso Villa
Bone resorption secondary to stress shielding is a leading cause of hip implant failure, primarily due to the stiffness mismatch between the femur and the prosthesis. Although anatomical stem designs generally provide improved load transfer, Dorr type C femurs often require straight stems to ensure adequate primary stability. This work presents a systematic approach to designing a straight, additively manufactured porous titanium hip stem aimed at minimizing stress shielding. The lattice architecture is customized to replicate the mechanical properties of bone based on patient-specific femoral CT scans. The performance of the resulting porous implant is numerically assessed under simplified physiological gait loading conditions. The implant behavior is evaluated through a homogenization strategy to model the lattice structure, significantly reducing the computational effort and making the methodology easily replicable. Compared to its full counterpart, the porous design achieves a significant reduction in predicted bone loss, suggesting that the proposed framework is a promising proof of concept for patient-specific implants. While further experimental validation and larger cohort studies are required, these findings highlight the potential of mechanically tunable porous structures to mitigate the stress shielding phenomenon in anatomical conditions such as Dorr type C femurs, which require straight stems.

19 February 2025 in International Journal for Numerical Methods in Biomedical Engineering
Verified
Journal Article
Open access
RCRoberta Cromi
Roberta Cromi
LCLuca Ciriello
Luca Ciriello
BFBerti Francesca
Berti Francesca
LBLuigi La Barbera
Luigi La Barbera
TVTomaso Villa
Tomaso Villa
GPGiancarlo Pennati
Giancarlo Pennati
The bi‐modular hip prosthesis is characterized by two tapered connections: a circular cross‐section at the head–neck interface and a rectangular cross‐section at the neck‐stem interface. Even if the latter guarantees customization, it concerns a high rate of early failure. The connection resistance is relatable to machining (tolerances cause angular mismatch), implantation (hammering force or manual), and usage (Body Mass Index [BMI]). Due to the lack of literature about the neck‐stem coupling, this work aims to investigate how the geometry of the rectangular taper connection and the external loads affect the fatigue strength of a bi‐modular hip prosthesis through a 3D Finite Element Model (FEM). Nine combinations of neck‐stem coupling are obtained considering the tolerances' limits on frontal and lateral angles as . The CoCr neck and the Ti6Al4V stem, studied in their halved, are constrained and loaded inspired by the standard ISO 7206: the stem is distally encastered simulating the embedding and tilted by 10° concerning the sagittal plane, while the force is applied vertically. First, the influence of the assembly is investigated using , , and ; then, a cyclical vertical force varying from to is imposed. Finally, one combination is analyzed in its integrity to evaluate the effect of the out‐of‐plane load. The study's findings concern: (i) a positive angular mismatch, which is responsible for proximal contacts, improves fatigue life, reducing Sines stress up to 33%; (ii) the higher the assembly force the higher the neck stability and the lower the extension of the overstressed lateral area; (iii) the implant fatigue resistance is directly proportional to the patient's BMI; and (iv) the out‐of‐plane external load causes a 40% increment in the fatigue failure risk.