Massimo Brignone

Dr. Massimo Brignone

Naval and Electrical Engineering Department, University of Genoa, 16145 Genoa, Italy
orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2018 in Energy
Verified
Journal Article
Closed access
IBIlaria Bendato
Ilaria Bendato
ABAndrea Bonfiglio
Andrea Bonfiglio
Massimo BrignoneMassimo Brignone
Massimo Brignone
FDFederico Delfino
Federico Delfino
FPFabio Pampararo
Fabio Pampararo
MRMansueto Rossi
Mansueto Rossi

18 December 2017 in IEEE Transactions on Electromagnetic Compatibility
Verified
Journal Article
Closed access
Massimo BrignoneMassimo Brignone
Massimo Brignone
Daniele MestrinerDaniele Mestriner
Daniele Mestriner
Renato ProcopioRenato Procopio
Renato Procopio
APAlexandre Piantini
Alexandre Piantini
Farhad RachidiFarhad Rachidi
Farhad Rachidi
Lightning overvoltages are one of the most dangerous factors affecting the power quality of a distribution grid. In medium voltage (MV) overhead distribution systems, lightning transients can be caused by either direct or indirect strikes. Indirect strikes are much more frequent than direct strikes and can cause flashovers, especially when the line insulation level is low. The most widely employed protection measures against lightning overvoltages are the use of the shield wires, and/or surge arresters, and increasing the line insulation level. In particular, many studies have shown a significant reduction in the induced voltage magnitudes, thanks to the use of the shield wires in both transmission and distribution systems. This paper deals with the possibility of adopting the shield wires to mitigate lightning induced overvoltages in MV networks, and proposes an analysis on the main parameters that influence their performances. This aim is pursued by means of a probabilistic and statistical analysis based on the response surface method (RSM), which permits to obtain the equation of the surface that best approximates a given model. The application and efficiency of the proposed RSM-based approach have been illustrated by applying it to a realistic situation of a rural distribution line.

3 August 2017 in Energies
Verified
Journal Article
Open access
PDF file
Andrea BonfiglioAndrea Bonfiglio
Andrea Bonfiglio
Massimo BrignoneMassimo Brignone
Massimo Brignone
MIMarco Invernizzi
Marco Invernizzi
Alessandro LabellaAlessandro Labella
Alessandro Labella
Daniele MestrinerDaniele Mestriner
Daniele Mestriner
Renato ProcopioRenato Procopio
Renato Procopio
Microgrids (MGs) may represent a solution in the near future to many problems in the energy and electric world scenarios; such as pollution, high reliability, efficiency and so on. In particular, MGs’ capability to work in an islanded configuration represents one of their most interesting features in terms of the improvement of the reliability of the system, the integration of renewable energy sources and the exploitation of the quick response and flexibility of power electronic devices in a stand-alone system. In order to study and validate innovative solutions and control strategies for islanded operation, there is a need to develop models for MG structures that can be reliable and sufficiently simple to be used for the purpose of the design and validation of innovative control systems. This paper proposes a simplified, first harmonic model for a generic structure of MG characterized by its use of only electronic power converter interfaced generation. The main advantages of the proposed method lie in the model’s simplicity and its reduced solving time, thanks to the limited number of necessary parameters to describe the system. Moreover, the developed formulation allows the avoidance of specific (and often licensed) software to simulate the system. The performances of the proposed model have been validated by means of a comparative analysis of the results obtained against a more accurate representation of the system performed in the power system CAD—electromagnetic transient and DC (PSCAD—EMTDC) environment, which allows for the representation of each component with a very high level of detail. Such comparison has been performed using the University of Genoa Savona Campus Smart Polygeneration Microgrid testbed facility, due to the availability of all the necessary numerical values.

17 February 2021 in IEEE Transactions on Electromagnetic Compatibility
Verified
Journal Article
Closed access
Daniele MestrinerDaniele Mestriner
Daniele Mestriner
Massimo BrignoneMassimo Brignone
Massimo Brignone
Renato ProcopioRenato Procopio
Renato Procopio
Martino NicoraMartino Nicora
Martino Nicora
EFElisabetta Fiori
Elisabetta Fiori
Farhad RachidiFarhad Rachidi
Farhad Rachidi
This article proposes a method for the derivation of a formula that links the maximum lightning-induced-overvoltage occurring on an overhead distribution line with the variables that characterize the lightning return stroke, such as the peak current, front duration, and stroke location. The coefficients of such formulas are obtained thanks to a limited number of lightning field-to-line coupling simulations, thus guaranteeing a significant computational time saving with respect to already existing methods. The method is presented first with a preliminary analysis to get some insight into the functional relationship between each of such variables and the overvoltage. Then, the method is presented and validated against numerical calculations performed with a dedicated code, both in terms of punctual evaluations and overvoltage distribution.

8 January 2019 in IEEE Transactions on Electromagnetic Compatibility
Verified
Journal Article
Closed access
Massimo BrignoneMassimo Brignone
Massimo Brignone
Daniele MestrinerDaniele Mestriner
Daniele Mestriner
Renato ProcopioRenato Procopio
Renato Procopio
APAlexandre Piantini
Alexandre Piantini
Farhad RachidiFarhad Rachidi
Farhad Rachidi
One of the main issues that has to be faced when evaluating lightning-induced overvoltages on a realistic network configuration is to implement the algorithm that solves the field-to-line coupling problem into an electromagnetic simulator that is able to represent with a high level of detail all the power system components. On one hand, numerical stability conditions of the finite-difference time-domain schemes have been deeply investigated in the presence of boundary conditions known analytically; on the other hand, there is not so much literature on the situations in which such conditions are provided in a numerical way through an external electromagnetic simulator. The study reveals that the commonly used linear extrapolation of currents at the line extremities might rise to numerical instabilities. An efficient solution using the method of characteristics is presented and validated.

10 March 2021 in IEEE Transactions on Electromagnetic Compatibility
Verified
Journal Article
Closed access
Martino NicoraMartino Nicora
Martino Nicora
Daniele MestrinerDaniele Mestriner
Daniele Mestriner
Massimo BrignoneMassimo Brignone
Massimo Brignone
Renato ProcopioRenato Procopio
Renato Procopio
EFElisabetta Fiori
Elisabetta Fiori
Farhad RachidiFarhad Rachidi
Farhad Rachidi
Dealing with lightning performance computation, researchers usually consider only negative downward first return strokes and the relevant channel-base peak current distribution. The aim of this article is to account for the lightning flash mechanism, which means to include also downward negative subsequent strokes and downward positive strokes, taking into account available distributions of the number of strokes per flash (i.e., the flash multiplicity) and of the distance among the impact points of the strokes within the same flash (i.e., the channel terminations distance). In this regard, to the best of the authors’ knowledge, the present study is the first one taking into account the multiple ground channel terminations in the lightning performance assessment. The obtained results show that both the negative subsequent strokes and multiple channel termination determine a significant increase in the estimated number of flashovers per year, and they need to be considered in the lightning performance assessment. On the other hand, considering positive downward strokes, a less remarkable increase in the estimated number of flashovers per year is observed.