This paper deals with scale models of power distribution systems for the study of lightning induced voltages on overhead lines. The scale model technique is useful for the investigation of situations which are prohibitively complex to be treated theoretically. For instance, urban distribution networks are usually characterized not only by complex topologies but also by the presence of nearby buildings, whose influence on the lightning induced effects can be successfully evaluated by means of reduced models. The paper first describes the scale model implemented for such a purpose at the University of Sao Paulo, Sao Paulo, Brazil. It then presents a comparison between the experimental data obtained with the scale model and the computer simulations obtained by using the LIOV-EMTP code, a software tool able of calculating lightning-induced electromagnetic transients in distribution systems having complex configurations. Finally, the paper shows an application of the scale model in the evaluation of lightning induced voltages on distribution networks considering the presence of nearby buildings
26 June 2009 in IEEE Transactions on Electromagnetic Compatibility
Lightning-induced overvoltages have a considerable impact on the power quality of overhead distribution and telecommunications systems, and various models have been developed for the computation of the electromagnetic transients caused by indirect strokes. The most adequate has been shown to be the one proposed by Agrawal ; the Rusck model can be visualized as a particular case, as both models are equivalent when the lightning channel is perpendicular to the ground plane. In this paper, an extension of the Rusck model that enables the calculation of lightning-induced transients considering flashes to nearby elevated structures and realistic line configurations is tested against data obtained from both natural lightning and scale model experiments. The latter, performed under controlled conditions, can be used also to verify the validity of other coupling models and relevant codes. The so-called Extended Rusck Model, which is shown to be sufficiently accurate, is applied to the analysis of lightning-induced voltages on lines with a shield wire and/or surge arresters. The investigation conducted indicates that the ratio between the peak values of the voltages induced by typical first and subsequent strokes can be either greater or smaller than the unity, depending on the line configuration.
CIGRE TB 549 (2013) is an update on previous CIGRE documents on the subject, published in Electra more than three decades ago. Lightning parameters needed in different engineering applications are reviewed. New experimental data, as well as the old data, are evaluated. Additional lightning parameters, previously not considered by CIGRE, are included. Possible geographical and seasonal variations in lightning parameters are examined. Specific applications are considered and recommendations are made.
Lightning overvoltages are one of the most dangerous factors affecting the power quality of a distribution grid. In medium voltage (MV) overhead distribution systems, lightning transients can be caused by either direct or indirect strikes. Indirect strikes are much more frequent than direct strikes and can cause flashovers, especially when the line insulation level is low. The most widely employed protection measures against lightning overvoltages are the use of the shield wires, and/or surge arresters, and increasing the line insulation level. In particular, many studies have shown a significant reduction in the induced voltage magnitudes, thanks to the use of the shield wires in both transmission and distribution systems. This paper deals with the possibility of adopting the shield wires to mitigate lightning induced overvoltages in MV networks, and proposes an analysis on the main parameters that influence their performances. This aim is pursued by means of a probabilistic and statistical analysis based on the response surface method (RSM), which permits to obtain the equation of the surface that best approximates a given model. The application and efficiency of the proposed RSM-based approach have been illustrated by applying it to a realistic situation of a rural distribution line.