Katrin Schmitt

Dr. Katrin Schmitt

orcid

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2007 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
KSKatrin Schmitt
Katrin Schmitt
BSBernd Schirmer
Bernd Schirmer
CHChristian Hoffmann
Christian Hoffmann
ABAlbrecht Brandenburg
Albrecht Brandenburg
PMPatrick Meyrueis
Patrick Meyrueis

6 January 2008 in Sensors
Verified
Journal Article
Open access
PDF file
KSKatrin Schmitt
Katrin Schmitt
KOKerstin Oehse
Kerstin Oehse
GSGerd Sulz
Gerd Sulz
CHChristian Hoffmann
Christian Hoffmann
Evanescent field sensors based on waveguide surfaces play an important rolewhere high sensitivity is required. Particularly tantalum pentoxide (Ta2O5) is a suitablematerial for thin-film waveguides due to its high refractive index and low attenuation.Many label-free biosensor systems such as grating couplers and interferometric sensors aswell as fluorescence-based systems benefit from this waveguide material leading toextremely high sensitivity. Some biosensor systems based on Ta2O5 waveguides alreadytook the step into commercialization. This report reviews the various detection systems interms of limit of detection, the applications, and the suitable surface chemistry.

13 June 2014 in Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences
Verified
Journal Article
Closed access
SJS. Janssen
S. Janssen
KSKatrin Schmitt
Katrin Schmitt
Michael BlankeMichael Blanke
Michael Blanke
MBM. L. Bauersfeld
M. L. Bauersfeld
JWJ. Wöllenstein
J. Wöllenstein
WLWalter Lang
Walter Lang
Ethylene is a gaseous ripening phytohormone of fruits and plants. Presently, ethylene is primarily measured with stationary equipment in laboratories. Applyingin situmeasurement at the point of natural ethylene generation has been hampered by the lack of portable units designed to detect ethylene at necessary resolutions of a few parts per billion. Moreover, high humidity inside controlled atmosphere stores or containers complicates the realization of gas sensing systems that are sufficiently sensitive, reliable, robust and cost efficient. In particular, three measurement principles have shown promising potential for fruit supply chains and were used to develop independent mobile devices: non-dispersive infrared spectroscopy, miniaturized gas chromatography and electrochemical measurement. In this paper, the measurement systems for ethylene are compared with regard to the needs in fruit logistics; i.e. sensitivity, selectivity, long-term stability, facilitation of automated measurement and suitability for mobile application. Resolutions of 20–10 ppb can be achieved in mobile applications with state-of-the-art equipment, operating with the three methods described in the following. The prices of these systems are in a range below €10 000.

1 February 2008 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
TNThomas Nagel
Thomas Nagel
EEEva Ehrentreich-Förster
Eva Ehrentreich-Förster
MSMahavir Singh
Mahavir Singh
KSKatrin Schmitt
Katrin Schmitt
ABAlbrecht Brandenburg
Albrecht Brandenburg
FBFrank F. Bier
Frank F. Bier

11 February 2019 in Sensors
Verified
Journal Article
Open access
PDF file
JKJohannes Kapp
Johannes Kapp
CWChristian Weber
Christian Weber
KSKatrin Schmitt
Katrin Schmitt
HPHans-Fridtjof Pernau
Hans-Fridtjof Pernau
JWJürgen Wöllenstein
Jürgen Wöllenstein
Nitrogen dioxide (NO2) is a poisonous trace gas that requires monitoring in urban areas. Accurate measurement in sub-ppm concentrations represents a wide application field for suitable economical sensors. We present a novel approach to measure NO2 with a photoacoustic sensor using a T-shaped resonance cell. An inexpensive UV-LED with a peak wavelength of 405 nm as radiation source as well as a commercial MEMS microphone for acoustic detection were used. In this work, a cell has been developed that enables a “non-contact” feedthrough of the divergent LED beam. Thus, unwanted background noise due to absorption on the inside walls is minimized. As part of the development, an acoustic simulation has been carried out to find the resonance frequencies and to visualize the resulting standing wave patterns in various geometries. The pressure amplitude was calculated for different shapes and sizes. A model iteratively optimized in this way forms the basis of a construction that was built for gas measurement by rapid prototyping methods. The real resonance frequencies were compared to the ones found in simulation. The limit of detection was determined in a nitrogen dioxide measurement to be 200 ppb (6 σ) for a cell made of aluminum.

29 March 2018 in Chemosensors
Verified
Journal Article
Open access
PDF file
KSKatrin Schmitt
Katrin Schmitt
KTKarina Tarantik
Karina Tarantik
CPCarolin Pannek
Carolin Pannek
JWJürgen Wöllenstein
Jürgen Wöllenstein
The damage caused by outbreaks of fire continues to be enormous despite ongoing improvements in fire detection and fighting. Therefore, the detection of fires at the earliest possible stage is essential. The latest developments in fire detection devices include the addition of carbon monoxide (CO) or temperature sensors into the widespread smoke detectors, but also alternative solutions are searched for. Advantageous is the direct detection of the most relevant fire gases CO and nitrogen dioxide (NO2), because they are produced very early in a developing fire. A sensitive, selective, and low-cost method to detect these gases is the use of colorimetric materials combined with a compact optical readout. In this review, we take account of recent developments in this research field and provide a comprehensive overview on suitable materials for CO and NO2 detection in fire gas sensing and first steps towards novel fire gas detectors.