Leah C Henze Bancroft

Dr. Leah C Henze Bancroft

orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 April 2019 in Journal of Magnetic Resonance Imaging
Verified
Journal Article
Closed access
PDF file
GLGeraldine J. Liao
Geraldine J. Liao
LBLeah C Henze Bancroft
Leah C Henze Bancroft
RSRoberta M. Strigel
Roberta M. Strigel
RCRhea D. Chitalia
Rhea D. Chitalia
DKDespina Kontos
Despina Kontos
HRHabib Rahbar
Habib Rahbar

1 April 2017 in Investigative Radiology
Verified
Journal Article
Closed access
CMCourtney K. Morrison
Courtney K. Morrison
LBLeah C Henze Bancroft
Leah C Henze Bancroft
WDWendy B. DeMartini
Wendy B. DeMartini
JHJames H. Holmes
James H. Holmes
KWKang Wang
Kang Wang
RSRoberta M. Strigel
Roberta M. Strigel
Objective: Currently, dynamic contrast-enhanced (DCE) breast magnetic resonance imaging (MRI) prioritizes spatial resolution over temporal resolution given the limitations of acquisition techniques. The purpose of our intrapatient study was to assess the ability of a novel high spatial and high temporal resolution DCE breast MRI method to maintain image quality compared with the clinical standard-of-care (SOC) MRI. Materials and Methods: Thirty patients, each demonstrating a focal area of enhancement (29 benign, 1 cancer) on their SOC MRI, consented to undergo a research DCE breast MRI on a second date. For the research DCE MRI, a method (DIfferential Subsampling with Cartesian Ordering [DISCO]) using pseudorandom k-space sampling, view sharing reconstruction, 2-point Dixon fat-water separation, and parallel imaging was used to produce images with an effective temporal resolution 6 times faster than the SOC MRI (27 vs 168 seconds, respectively). Both the SOC and DISCO MRI scans were acquired with matching spatial resolutions of 0.8 × 0.8 × 1.6 mm3. Image quality (distortion/artifacts, resolution, fat suppression, lesion conspicuity, perceived signal-to-noise ratio, and overall image quality) was scored by 3 radiologists in a blinded reader study. Results: Differences in image quality scores between the DISCO and SOC images were all less than 0.8 on a 10-point scale, and both methods were assessed as providing diagnostic image quality in all cases. DISCO images with the same high spatial resolution, but 6 times the effective temporal resolution as the SOC MRI scans, were produced, yielding 20 postcontrast time points with DISCO compared with 3 for the SOC MRI, over the same total time interval. Conclusions: DISCO provided comparable image quality compared with the SOC MRI, while also providing 6 times faster effective temporal resolution and the same high spatial resolution.

14 November 2019 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
PDF file
XWXiaoke Wang
Xiaoke Wang
TCTimothy J. Colgan
Timothy J. Colgan
LHLouis A. Hinshaw
Louis A. Hinshaw
NRNathan T. Roberts
Nathan T. Roberts
LBLeah C Henze Bancroft
Leah C Henze Bancroft
SRScott B. Reeder
Scott B. Reeder

18 October 2023 in Tomography
Verified
Journal Article
Open access
PDF file
TATimothy Jameson Allen
Timothy Jameson Allen
LBLeah C Henze Bancroft
Leah C Henze Bancroft
OUOrhan Unal
Orhan Unal
LELloyd D. Estkowski
Lloyd D. Estkowski
TCTy A. Cashen
Ty A. Cashen
JHJames H Holmes
James H Holmes
Deep learning (DL) reconstruction techniques to improve MR image quality are becoming commercially available with the hope that they will be applicable to multiple imaging application sites and acquisition protocols. However, before clinical implementation, these methods must be validated for specific use cases. In this work, the quality of standard-of-care (SOC) T2w and a high-spatial-resolution (HR) imaging of the breast were assessed both with and without prototype DL reconstruction. Studies were performed using data collected from phantoms, 20 retrospectively collected SOC patient exams, and 56 prospectively acquired SOC and HR patient exams. Image quality was quantitatively assessed via signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and edge sharpness. Qualitatively, all in vivo images were scored by either two or four radiologist readers using 5-point Likert scales in the following categories: artifacts, perceived sharpness, perceived SNR, and overall quality. Differences in reader scores were tested for significance. Reader preference and perception of signal intensity changes were also assessed. Application of the DL resulted in higher average SNR (1.2–2.8 times), CNR (1.0–1.8 times), and image sharpness (1.2–1.7 times). Qualitatively, the SOC acquisition with DL resulted in significantly improved image quality scores in all categories compared to non-DL images. HR acquisition with DL significantly increased SNR, sharpness, and overall quality compared to both the non-DL SOC and the non-DL HR images. The acquisition time for the HR data only required a 20% increase compared to the SOC acquisition and readers typically preferred DL images over non-DL counterparts. Overall, the DL reconstruction demonstrated improved T2w image quality in clinical breast MRI.

14 February 2018 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
PDF file
JJJorge E. Jimenez
Jorge E. Jimenez
RSRoberta M. Strigel
Roberta M. Strigel
KJKevin M. Johnson
Kevin M. Johnson
LBLeah C Henze Bancroft
Leah C Henze Bancroft
SRScott B. Reeder
Scott B. Reeder
WBWalter F. Block
Walter F. Block

15 March 2013 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
CMCatherine J. Moran
Catherine J. Moran
EBEthan K. Brodsky
Ethan K. Brodsky
LBLeah C Henze Bancroft
Leah C Henze Bancroft
SRScott B. Reeder
Scott B. Reeder
HYHuanzhou Yu
Huanzhou Yu
WBWalter F. Block
Walter F. Block
Radial trajectories facilitate high‐resolution balanced steady state free precession (bSSFP) because the efficient gradients provide more time to extend the trajectory in k‐space. A number of radial bSSFP methods that support fat–water separation have been developed; however, most of these methods require an environment with limited B0 inhomogeneity. In this work, high‐resolution bSSFP with fat–water separation is achieved in more challenging B0 environments by combining a 3D radial trajectory with the IDEAL chemical species separation method. A method to maintain very high resolution within the timing constraints of bSSFP and IDEAL is described using a dual‐pass pulse sequence. The sampling of a unique set of radial lines at each echo time is investigated as a means to circumvent the longer scan time that IDEAL incurs as a multiecho acquisition. The manifestation of undersampling artifacts in this trajectory and their effect on chemical species separation are investigated in comparison to the case in which each echo samples the same set of radial lines. This new bSSFP method achieves 0.63 mm isotropic resolution in a 5‐min scan and is demonstrated in difficult in vivo imaging environments, including the breast and a knee with ACL reconstruction hardware at 1.5 T. Magn Reson Med 71:95–104, 2014. © 2013 Wiley Periodicals, Inc.