Orhan Unal

Dr. Orhan Unal

orcid

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 March 2006 in Journal of Magnetic Resonance Imaging
Verified
Journal Article
Open access
PDF file
OUOrhan Unal
Orhan Unal
JLJunwei Li
Junwei Li
WCWeiguo Cheng
Weiguo Cheng
HYHyuk Yu
Hyuk Yu
CSCharles M. Strother
Charles M. Strother
Purpose To investigate the potential utility of magnetic resonance (MR)‐visible coatings for passive visualization of therapeutic endovascular devices such as catheters and guidewires. Materials and Methods Using a multistep coating process, gadolinium‐based coatings were applied to commercially available off‐the‐shelf catheters and guidewires. These coated devices were imaged in phantoms made of fat‐free yogurt, saline, and whole blood and also in live canine aorta on a 1.5‐T cardiovascular MR scanner using T1‐weighted two‐dimensional radiofrequency (RF)‐spoiled gradient‐recalled echo, two‐dimensional spin echo, and three‐dimensional RF‐spoiled gradient‐recalled echo techniques. Results Commercially available off‐the shelf catheters (4, 5, and 6 French) and guidewires (0.038 inch) were clearly visualized in all phantoms and canine aorta and the coatings proved to be durable and imageable without degradation in signal intensity up to 24 hours. MR‐visible coatings address some of the shortcomings that have previously limited the role of MR as a guidance tool. Conclusion Both in vitro and in vivo visualization of therapeutic endovascular devices coated with MR‐visible coatings are found to be clinically viable. J. Magn. Reson. Imaging 2006.

15 May 2021 in International Journal of Biomedical Imaging
Verified
Journal Article
Open access
PDF file
EIEl-Sayed H Ibrahim
El-Sayed H Ibrahim
LFLuba Frank
Luba Frank
DBDhiraj Baruah
Dhiraj Baruah
VAV. Emre Arpinar
V. Emre Arpinar
ANAndrew Scott Nencka
Andrew Scott Nencka
CBCarmen Bergom
Carmen Bergom
Cardiac magnetic resonance imaging (CMR) is considered the gold standard for measuring cardiac function. Further, in a single CMR exam, information about cardiac structure, tissue composition, and blood flow could be obtained. Nevertheless, CMR is underutilized due to long scanning times, the need for multiple breath-holds, use of a contrast agent, and relatively high cost. In this work, we propose a rapid, comprehensive, contrast-free CMR exam that does not require repeated breath-holds, based on recent developments in imaging sequences. Time-consuming conventional sequences have been replaced by advanced sequences in the proposed CMR exam. Specifically, conventional 2D cine and phase-contrast (PC) sequences have been replaced by optimized 3D-cine and 4D-flow sequences, respectively. Furthermore, conventional myocardial tagging has been replaced by fast strain-encoding (SENC) imaging. Finally, T1 and T2 mapping sequences are included in the proposed exam, which allows for myocardial tissue characterization. The proposed rapid exam has been tested in vivo. The proposed exam reduced the scan time from >1 hour with conventional sequences to <20 minutes. Corresponding cardiovascular measurements from the proposed rapid CMR exam showed good agreement with those from conventional sequences and showed that they can differentiate between healthy volunteers and patients. Compared to 2D cine imaging that requires 12-16 separate breath-holds, the implemented 3D-cine sequence allows for whole heart coverage in 1-2 breath-holds. The 4D-flow sequence allows for whole-chest coverage in less than 10 minutes. Finally, SENC imaging reduces scan time to only one slice per heartbeat. In conclusion, the proposed rapid, contrast-free, and comprehensive cardiovascular exam does not require repeated breath-holds or to be supervised by a cardiac imager. These improvements make it tolerable by patients and would help improve cost effectiveness of CMR and increase its adoption in clinical practice.

13 February 2020 in The International Journal of Cardiovascular Imaging
Verified
Journal Article
Open access
PDF file
JEJennifer Erley
Jennifer Erley
VZVictoria Zieschang
Victoria Zieschang
TLTomas Lapinskas
Tomas Lapinskas
ADAylin Demir
Aylin Demir
SWStephanie Wiesemann
Stephanie Wiesemann
SKSebastian Kelle
Sebastian Kelle
Myocardial strain is a convenient parameter to quantify left ventricular (LV) function. Fast strain-encoding (fSENC) enables the acquisition of cardiovascular magnetic resonance images for strain-measurement within a few heartbeats during free-breathing. It is necessary to analyze inter-vendor agreement of techniques to determine strain, such as fSENC, in order to compare existing studies and plan multi-center studies. Therefore, the aim of this study was to investigate inter-vendor agreement and test-retest reproducibility of fSENC for three major MRI-vendors. fSENC-images were acquired three times in the same group of 15 healthy volunteers using 3 Tesla scanners from three different vendors: at the German Heart Institute Berlin, the Charité University Medicine Berlin-Campus Buch and the Theresien-Hospital Mannheim. Volunteers were scanned using the same imaging protocol composed of two fSENC-acquisitions, a 15-min break and another two fSENC-acquisitions. LV global longitudinal and circumferential strain (GLS, GCS) were analyzed by a trained observer (Myostrain 5.0, Myocardial Solutions) and for nine volunteers repeatedly by another observer. Inter-vendor agreement was determined using Bland-Altman analysis. Test-retest reproducibility and intra- and inter-observer reproducibility were analyzed using intraclass correlation coefficient (ICC) and coefficients of variation (CoV). Inter-vendor agreement between all three sites was good for GLS and GCS, with biases of 0.01–1.88%. Test-retest reproducibility of scans before and after the break was high, shown by ICC- and CoV values of 0.63–0.97 and 3–9% for GLS and 0.69–0.82 and 4–7% for GCS, respectively. Intra- and inter-observer reproducibility were excellent for both parameters (ICC of 0.77–0.99, CoV of 2–5%). This trial demonstrates good inter-vendor agreement and test–retest reproducibility of GLS and GCS measurements, acquired at three different scanners from three different vendors using fSENC. The results indicate that it is necessary to account for a possible bias (< 2%) when comparing strain measurements of different scanners. Technical differences between scanners, which impact inter-vendor agreement, should be further analyzed and minimized.DRKS Registration Number: 00013253.Universal Trial Number (UTN): U1111-1207-5874.

30 April 2025 in Journal of Imaging
Verified
Journal Article
Open access
PDF file
Abdussalam Elhadi ElhanashiAbdussalam Elhadi Elhanashi
Abdussalam Elhadi Elhanashi
Sergio SaponaraSergio Saponara
Sergio Saponara
Qinghe ZhengQinghe Zheng
Qinghe Zheng
Nawal AlMutairiNawal AlMutairi
Nawal AlMutairi
Yashbir SinghYashbir Singh
Yashbir Singh
SFShahriar Faghani
Shahriar Faghani
Artificial intelligence (AI)-based object detection in radiology can assist in clinical diagnosis and treatment planning. This article examines the AI-based object detection models currently used in many imaging modalities, including X-ray Magnetic Resonance Imaging (MRI), Computed Tomography (CT), and Ultrasound (US). The key models from the convolutional neural network (CNN) as well as the contemporary transformer and hybrid models are analyzed based on their ability to detect pathological features, such as tumors, lesions, and tissue abnormalities. In addition, this review offers a closer look at the strengths and weaknesses of these models in terms of accuracy, robustness, and speed in real clinical settings. The common issues related to these models, including limited data, annotation quality, and interpretability of AI decisions, are discussed in detail. Moreover, the need for strong applicable models across different populations and imaging modalities are addressed. The importance of privacy and ethics in general data use as well as safety and regulations for healthcare data are emphasized. The future potential of these models lies in their accessibility in low resource settings, usability in shared learning spaces while maintaining privacy, and improvement in diagnostic accuracy through multimodal learning. This review also highlights the importance of interdisciplinary collaboration among artificial intelligence researchers, radiologists, and policymakers. Such cooperation is essential to address current challenges and to fully realize the potential of AI-based object detection in radiology.

18 October 2023 in Tomography
Verified
Journal Article
Open access
PDF file
TATimothy Jameson Allen
Timothy Jameson Allen
LBLeah C Henze Bancroft
Leah C Henze Bancroft
OUOrhan Unal
Orhan Unal
LELloyd D. Estkowski
Lloyd D. Estkowski
TCTy A. Cashen
Ty A. Cashen
JHJames H Holmes
James H Holmes
Deep learning (DL) reconstruction techniques to improve MR image quality are becoming commercially available with the hope that they will be applicable to multiple imaging application sites and acquisition protocols. However, before clinical implementation, these methods must be validated for specific use cases. In this work, the quality of standard-of-care (SOC) T2w and a high-spatial-resolution (HR) imaging of the breast were assessed both with and without prototype DL reconstruction. Studies were performed using data collected from phantoms, 20 retrospectively collected SOC patient exams, and 56 prospectively acquired SOC and HR patient exams. Image quality was quantitatively assessed via signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and edge sharpness. Qualitatively, all in vivo images were scored by either two or four radiologist readers using 5-point Likert scales in the following categories: artifacts, perceived sharpness, perceived SNR, and overall quality. Differences in reader scores were tested for significance. Reader preference and perception of signal intensity changes were also assessed. Application of the DL resulted in higher average SNR (1.2–2.8 times), CNR (1.0–1.8 times), and image sharpness (1.2–1.7 times). Qualitatively, the SOC acquisition with DL resulted in significantly improved image quality scores in all categories compared to non-DL images. HR acquisition with DL significantly increased SNR, sharpness, and overall quality compared to both the non-DL SOC and the non-DL HR images. The acquisition time for the HR data only required a 20% increase compared to the SOC acquisition and readers typically preferred DL images over non-DL counterparts. Overall, the DL reconstruction demonstrated improved T2w image quality in clinical breast MRI.

6 February 2013 in Journal of Magnetic Resonance Imaging
Verified
Journal Article
Open access
PDF file
SKSteve Kecskemeti
Steve Kecskemeti
KJKevin Johnson
Kevin Johnson
Christopher FrancoisChristopher Francois
Christopher Francois
MSMark L. Schiebler
Mark L. Schiebler
OUOrhan Unal
Orhan Unal
Purpose To develop and validate a novel free‐breathing 3D radial late gadolinium‐enhanced magnetic resonance imaging technique (3D LGE‐MRI) with isotropic resolution and retrospective inversion time (TI) selection for myocardial viability imaging. Materials and Methods The 3D radial LGE‐MRI method featuring an interleaved and bit‐reversed radial k‐space trajectory was evaluated in 12 subjects that also had clinical breath‐hold Cartesian 2D LGE‐MRI. The 3D LGE‐MRI acquisition requires a predicted TI and a user‐controlled data acquisition window that determines the sampling width around the predicted TI. Sliding window reconstructions with update rates of 1× the repetition time (TR) allow for a user selectable TI to obtain the maximum nulling of the myocardium. The retrospective nature of the acquisition allows the user to choose from a range of possible TI times centered on the expected TI. Those projections most corrupted by respiratory motion, as determined by a respiratory bellows signal, were resampled according to the diminishing variance algorithm. The quality of the left ventricular myocardial nulling on the 3D LGE‐MRI and 2D LGE‐MRI was assessed using a 4‐point Likert scale by two experienced radiologists. Comparison of image quality scores for the two methods was performed using generalized estimating equations. Results All 3D LGE‐MRI cases produced similar nulling of myocardial signal as the 2D LGE‐MRI. The image quality of myocardial nulling was not significantly different between the two acquisitions (mean nulling of 3.4 for 2D vs. 3.1 for 3D, and P = 0.0645). The average absolute deviation from mean scores was also not determined to be statistically significant (1.8 for 2D and 0.4 for 3D and P = 0.1673). Total acquisition time was ∼9 minutes for 3D LGE‐MRI with voxel sizes ranging from 1.63 to 2.03 mm3. Conversely, the total imaging time was twice as long for the 2D DCE‐MRI (>17 minutes) with an eight times larger voxel size of 1.4 × 2.2 × 7.0 mm. Conclusion The 3D LGE‐MRI technique demonstrated in this study is a promising alternative for the assessment of myocardial viability in patients who have difficulty sustaining breath‐holds for the clinical standard 2D LGE‐MRI. J. Magn. Reson. Imaging 2013;38:1276–1282.