Victor Huayamave

Dr. Victor Huayamave

Department of Mechanical Engineering, Embry-Riddle Aeronautical University, 1 Aerospace Boulevard, Daytona Beach, FL 32114, USA
orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2015 in Journal of Biomechanics
Verified
Journal Article
Closed access
Victor HuayamaveVictor Huayamave
Victor Huayamave
CRChristopher Rose
Christopher Rose
SSSheila Serra
Sheila Serra
BJBrendan Jones
Brendan Jones
EDEduardo Divo
Eduardo Divo
CPCharles T. Price
Charles T. Price

6 March 2017 in International Journal of Numerical Methods for Heat & Fluid Flow
Verified
Journal Article
Closed access
Victor HuayamaveVictor Huayamave
Victor Huayamave
ACAndres Ceballos
Andres Ceballos
CBCarolina Barriento
Carolina Barriento
HSHubert Seigneur
Hubert Seigneur
SBStephen Barkaszi
Stephen Barkaszi
AKAlain Kassab
Alain Kassab
Purpose: Wind loading calculations are currently performed according to the ASCE 7 standard. Values in this standard were estimated from simplified models that do not necessarily take into account relevant flow characteristics. Thus, the standard does not have provisions to handle the majority of rooftop photovoltaic (PV) systems. Accurate solutions for this problem can be produced using a full-fledged three-dimensional computational fluid dynamics (CFD) analysis. Unfortunately, CFD requires enormous computation times, and its use would be unsuitable for this application which requires real-time solutions. To this end, a real-time response framework based on the proper orthogonal decomposition (POD) method is proposed. Design/methodology/approach: A real-time response framework based on the POD method was used. This framework used beforehand and off-line CFD solutions from an extensive data set developed using a predefined design space. Solutions were organized to form the basis snapshots of a POD matrix. The interpolation network using a radial-basis function (RBF) was used to predict the solution from the POD method given a set of values of the design variables. The results presented assume varying design variables for wind speed and direction on typical PV roof installations. Findings: The trained POD–RBF interpolation network was tested and validated by performing the fast-algebraic interpolation to obtain the pressure distribution on the PV system surface and they were compared to actual grid-converged fully turbulent 3D CFD solutions at the specified values of the design variables. The POD network was validated and proved that large-scale CFD problems can be parametrized and simplified by using this framework. Originality/value: The solar power industry, engineering design firms and the society as a whole could realize significant savings with the availability of a real-time in situ wind-load calculator that can prove essential for plug-and-play installation of PV systems. Additionally, this technology allows for automated parametric design optimization to arrive at the best fit for a set of given operating conditions. All these tasks are currently prohibited because of the massive computational resources and time required to address large-scale CFD analysis problems, all made possible by a simple but robust technology that can yield massive savings for the solar industry.

1 February 2020 in Clinical Biomechanics
Verified
Journal Article
Open access
Victor HuayamaveVictor Huayamave
Victor Huayamave
BLBlake Lozinski
Blake Lozinski
CRChristopher Rose
Christopher Rose
HAHessein Ali
Hessein Ali
AKAlain Kassab
Alain Kassab
CPCharles Price
Charles Price
Earlier clinical reports have identified femoral anteversion as a factor associated with developmental dysplasia of the hip. This study investigates the biomechanical influence of femoral anteversion on severe dislocations and its effect on hip reduction using the Pavlik harness. A computational model of an infant lower-extremity, representing a ten-week old female was used to analyze the biomechanics of anteversion angles ranging from 30° to 70° when severe dislocation was being treated with the Pavlik harness. Specifically, the effects and relationships between muscle passive response and femoral anteversion angle were investigated over a range of hip abduction and external rotation. Results of this study suggest that increased femoral anteversion may decrease the success rate for treatment of high-grade developmental dysplasia of the hip when using the Pavlik harness. However, hip external rotation and decreased abduction in the harness may facilitate initial reduction in these cases. This biomechanical study may help explain why dissections of newborn specimen with developmental dysplasia of the hip have shown normal distribution of femoral anteversion in contrast to studies of patients requiring surgery where greater frequency of increased femoral anteversion has been reported. This study also suggests that adjusting the Pavlik harness to increase external hip rotation and decrease hip abduction may facilitate initial reduction for severe dislocations with increased femoral anteversion.

2 April 2024 in Journal of Engineering and Science in Medical Diagnostics and Therapy
Verified
Journal Article
Open access
PDF file
SPSheridan Colum-YouBai Perry
Sheridan Colum-YouBai Perry
MFMatthew Folkman
Matthew Folkman
TOTakara O'BRien
Takara O'BRien
LWLauren A. Wilson
Lauren A. Wilson
ECEric Coyle
Eric Coyle
Victor HuayamaveVictor Huayamave
Victor Huayamave
Developmental dysplasia of the hip (DDH) is a condition in which the acetabular socket inadequately contains the femoral head (FH). If left untreated, DDH can result in degenerative changes in the hip joint. Several imaging techniques are used for DDH assessment. In radiographs, the acetabular index (ACIN), center-edge angle, Sharp's angle (SA), and migration percentage (MP) metrics are used to assess DDH. Determining these metrics is time-consuming and repetitive. This study uses a convolutional neural network (CNN) to identify radiographic measurements and improve traditional methods of identifying DDH. The dataset consisted of 60 subject radiographs rotated along the craniocaudal and mediolateral axes 25 times, generating 1500 images. A CNN detection algorithm was used to identify key radiographic metrics for the diagnosis of DDH. The algorithm was able to detect the metrics with reasonable accuracy in comparison to the manually computed metrics. The CNN performed well on images with high contrast margins between bone and soft tissues. In comparison, the CNN was not able to identify some critical points for metric calculation on a few images that had poor definition due to low contrast between bone and soft tissues. This study shows that CNNs can efficiently measure clinical parameters to assess DDH on radiographs with high contrast margins between bone and soft tissues with purposeful rotation away from an ideal image. Results from this study could help inform and broaden the existing bank of information on using CNNs for radiographic measurement and medical condition prediction.

31 August 2023 in Electronics
Verified
Journal Article
Open access
PDF file
Wangdo KimWangdo Kim
Wangdo Kim
EVEmir A. Vela
Emir A. Vela
SKSean S Kohles
Sean S Kohles
Victor HuayamaveVictor Huayamave
Victor Huayamave
OGOscar Gonzalez
Oscar Gonzalez
Inertial kinetics and kinematics have substantial influences on human biomechanical function. A new algorithm for Inertial Measurement Unit (IMU)-based motion tracking is presented in this work. The primary aims of this paper are to combine recent developments in improved biosensor technology with mainstream motion-tracking hardware to measure the overall performance of human movement based on joint axis-angle representations of limb rotation. This work describes an alternative approach to representing three-dimensional rotations using a normalized vector around which an identified joint angle defines the overall rotation, rather than a traditional Euler angle approach. Furthermore, IMUs allow for the direct measurement of joint angular velocities, offering the opportunity to increase the accuracy of instantaneous axis of rotation estimations. Although the axis-angle representation requires vector quotient algebra (quaternions) to define rotation, this approach may be preferred for many graphics, vision, and virtual reality software applications. The analytical method was validated with laboratory data gathered from an infant dummy leg’s flexion and extension knee movements and applied to a living subject’s upper limb movement. The results showed that the novel approach could reasonably handle a simple case and provide a detailed analysis of axis-angle migration. The described algorithm could play a notable role in the biomechanical analysis of human joints and offers a harbinger of IMU-based biosensors that may detect pathological patterns of joint disease and injury.

Verified
Journal Article
Open access
PDF file
YLYeram Lim
Yeram Lim
TCTamara Chambers
Tamara Chambers
Christine Dailey WalckChristine Dailey Walck
Christine Dailey Walck
SSSafeer F Siddicky
Safeer F Siddicky
EMErin Mannen
Erin Mannen
Victor HuayamaveVictor Huayamave
Victor Huayamave
Musculoskeletal computational models provide a non-invasive approach to investigate human movement biomechanics. These models could be particularly useful for pediatric applications where in vivo and in vitro biomechanical parameters are difficult or impossible to examine using physical experiments alone. The objective was to develop a novel musculoskeletal subject-specific infant model to investigate hip joint biomechanics during cyclic leg movements. Experimental motion-capture marker data of a supine-lying 2-month-old infant were placed on a generic GAIT 2392 OpenSim model. After scaling the model using body segment anthropometric measurements and joint center locations, inverse kinematics and dynamics were used to estimate hip ranges of motion and moments. For the left hip, a maximum moment of 0.975 Nm and a minimum joint moment of 0.031 Nm were estimated at 34.6° and 65.5° of flexion, respectively. For the right hip, a maximum moment of 0.906 Nm and a minimum joint moment of 0.265 Nm were estimated at 23.4° and 66.5° of flexion, respectively. Results showed agreement with reported values from the literature. Further model refinements and validations are needed to develop and establish a normative infant dataset, which will be particularly important when investigating the movement of infants with pathologies such as developmental dysplasia of the hip. This research represents the first step in the longitudinal development of a model that will critically contribute to our understanding of infant growth and development during the first year of life.