Hyeseon Lee

Ms. Hyeseon Lee

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 October 2023 in Energies
Verified
Journal Article
Open access
PDF file
HLHyeseon Lee
Hyeseon Lee
BLByungsung Lee
Byungsung Lee
GHGyurim Han
Gyurim Han
YKYuri Kim
Yuri Kim
YKYongha Kim
Yongha Kim
To supply stable and high-quality power according to the advancement of industrial growth, electric power companies have performed maintenance of power facilities using various methods. In the case of domestic power distribution facilities, there are limitations in performing diagnostic management on all facilities owing to the large number of facilities; therefore, old facilities are managed using the health index assessment method. The health index assessment comprises only facility operation data and external environmental data and is managed only for four types of distribution facilities including overhead/underground transformers and switchgears. In the case of high voltage overhead lines, there are a large number of wires such as transformers and switchgears connected to the lines, and the ripple effect of power outages is large. However, in Korea, there is no overhead line health index standard. In overseas cases, a health index for overhead lines was developed, but only the material characteristics and surrounding environment of the overhead lines were considered and economic feasibility was not considered. Therefore, in this paper, we developed a health index evaluation methodology for ultra-high voltage overhead lines that considers economic feasibility. In this paper, unlike the existing health index evaluation method that uses only operational data and external environmental data to determine facility performance evaluation and aging replacement standards, we developed an economic health index evaluation methodology that additionally considers failure probability and risk costs. Using the health index assessment methodology developed in this paper, it is possible to expect a reduction in facility operating costs and investment costs from the perspective of the electric power companies through the replacement of old extra-high voltage overhead cables. In addition, from the perspective of consumers, it is expected to increase power reliability and reduce the ripple effect of failure by preferentially replacing equipment with a high probability of failure.

30 August 2024 in Energies
Verified
Journal Article
Open access
PDF file
BSBOOHYUN SHIN
BOOHYUN SHIN
HLHyeseon Lee
Hyeseon Lee
SCSungyun Choi
Sungyun Choi
In Korea, the demand for complete underground installation of power distribution equipment installed on roads and green areas is increasing. In addition, KEPCO is making efforts to build a more reliable system for the underground distribution system. To meet these needs, this paper proposes the S-substation. In the S-substation, an RMU, a large power transformer, and an LV-Board (including ATCB and MCCB) are installed within the underground structure. This paper proposes three models to apply the S-substation to the underground distribution system. Power flow analysis is conducted for each model by simulating a variety of loads and DERs, and the frequency fluctuations are also examined under different distribution system events. An economic analysis is also conducted to select the optimal model. The economic analysis focuses on VOLL and construction costs. Based on power flow and economic analysis, one model is selected, and the underground distribution system that the model is applied is presented.

21 August 2024 in Journal of Electrical Engineering & Technology
Verified
Journal Article
Closed access
PDF file
BSBOOHYUN SHIN
BOOHYUN SHIN
HLHyeseon Lee
Hyeseon Lee
GOGi-Dae Oh
Gi-Dae Oh
SKSeung-Chul Kim
Seung-Chul Kim

16 May 2025 in Applied Sciences
Verified
Journal Article
Open access
PDF file
BSBOOHYUN SHIN
BOOHYUN SHIN
CKChang-Hwan Kim
Chang-Hwan Kim
HLHyeseon Lee
Hyeseon Lee
SCSungyun Choi
Sungyun Choi
In areas such as remote, rural, and mountainous regions, supplying low-voltage three-phase power has traditionally required distribution line extension and transformer installation. However, these areas often yield low electricity revenues, making cost recovery difficult for utilities. To address this challenge, this paper proposes a Single-to-Three-Phase Converter (STPC) capable of converting single-phase low-voltage input into three-phase output for use in low-voltage distribution systems. The STPC topology employs a single-phase half-bridge AC–DC stage and a three-phase full-bridge inverter stage using SiC-MOSFETs. To validate the system, simulations and experiments were conducted under various load conditions, including unbalanced, nonlinear, and motor loads. The results show that STPC maintains output stability while minimizing impact on the existing grid. The findings demonstrate STPC’s feasibility as an alternative to conventional line extension and transformer installation, with potential for application in grid-forming and low-voltage distribution current (LVDC) systems.

14 September 2023 in Preprints.org
Verified
Preprint
Open access
PDF file
HLHyeseon Lee
Hyeseon Lee
BLByungsung Lee
Byungsung Lee
GHGyurim Han
Gyurim Han
YKYuri Kim
Yuri Kim
YKYongha Kim
Yongha Kim
To supply stable and high-quality power according to the advancement of industrial growth, electric power companies have performed maintenance of power facilities using various meth-ods. In the case of domestic power distribution facilities, there are limitations in performing di-agnostic management on all facilities owing to the large number of facilities; therefore, old fa-cilities are managed by the health index assessment method. The health index assessment com-prises only facility operation data and external environmental data and is managed only for four types of distribution facilities, including overhead/underground transformers and switchgear. In the case of extra high–voltage overhead wires, there is no standard for old replacement, despite the large number of wires, such as transformers and switchgear, and the large ripple effect of power failure in the event of a power outage. Therefore, in this paper, a health index assessment methodology for extra-high voltage overhead cables was developed. In this paper, we devel-oped an economic health index assessment methodology that additionally considers risk cost, which is different from the existing health index assessment method that uses only operational data and external environmental data to determine facility performance evaluation and aging replacement criteria. Using the health index assessment methodology developed in this paper, it is possible to expect a reduction in facility operating costs and investment costs from the per-spective of electric power companies through the replacement of old extra-high voltage over-head cables. In addition, from the perspective of consumers, it is expected to increase power re-liability and reduce the ripple effect of failure by preferentially replacing equipment with a high probability of failure.