Gyurim Han

Ms. Gyurim Han


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 October 2023 in Energies
Verified
Journal Article
Open access
PDF file
HLHyeseon Lee
Hyeseon Lee
BLByungsung Lee
Byungsung Lee
GHGyurim Han
Gyurim Han
YKYuri Kim
Yuri Kim
YKYongha Kim
Yongha Kim
To supply stable and high-quality power according to the advancement of industrial growth, electric power companies have performed maintenance of power facilities using various methods. In the case of domestic power distribution facilities, there are limitations in performing diagnostic management on all facilities owing to the large number of facilities; therefore, old facilities are managed using the health index assessment method. The health index assessment comprises only facility operation data and external environmental data and is managed only for four types of distribution facilities including overhead/underground transformers and switchgears. In the case of high voltage overhead lines, there are a large number of wires such as transformers and switchgears connected to the lines, and the ripple effect of power outages is large. However, in Korea, there is no overhead line health index standard. In overseas cases, a health index for overhead lines was developed, but only the material characteristics and surrounding environment of the overhead lines were considered and economic feasibility was not considered. Therefore, in this paper, we developed a health index evaluation methodology for ultra-high voltage overhead lines that considers economic feasibility. In this paper, unlike the existing health index evaluation method that uses only operational data and external environmental data to determine facility performance evaluation and aging replacement standards, we developed an economic health index evaluation methodology that additionally considers failure probability and risk costs. Using the health index assessment methodology developed in this paper, it is possible to expect a reduction in facility operating costs and investment costs from the perspective of the electric power companies through the replacement of old extra-high voltage overhead cables. In addition, from the perspective of consumers, it is expected to increase power reliability and reduce the ripple effect of failure by preferentially replacing equipment with a high probability of failure.

30 October 2022 in Journal of the Korean Solar Energy Society
Verified
Journal Article
Open access
YKYong-Ha Kim
Yong-Ha Kim
YKYu-Ri Kim
Yu-Ri Kim
SHSang-Hwa Han
Sang-Hwa Han
HLHye-Seon Lee
Hye-Seon Lee
JPJong-Min Park
Jong-Min Park
GHGyurim Han
Gyurim Han

30 December 2023 in Journal of the Korean Solar Energy Society
Verified
Journal Article
Open access
PDF file
YKYong-Ha Kim
Yong-Ha Kim
YKYu-Ri Kim
Yu-Ri Kim
GHGyurim Han
Gyurim Han
As the supply of renewable energy increases, instability problems in power systems arise because of the output volatility and intermittency of renewable energy. Sector coupling has recently emerged as a solution to renewable energy problems. Therefore, in this study, P2H, which converts power into heat during sector coupling, was considered. Considering P2H in district cooling and heating systems, an optimal operation algorithm for district heating and cooling facilities was developed. The operating characteristics of district energy heat source facilities were considered to maximize profits, and economical heat storage tank operation was also considered for P2H. In addition, useful information for introducing P2H was derived through a sensitivity analysis to ensure economic feasibility for district cooling and heating business operators when P2H was implemented.

30 December 2023 in Journal of the Korean Solar Energy Society
Verified
Journal Article
Open access
PDF file
YKYong-Ha Kim
Yong-Ha Kim
YKYu-Ri Kim
Yu-Ri Kim
GHGyurim Han
Gyurim Han
To achieve carbon neutrality, the proportion of renewable energy must increase according to the 2030 implementation plan. However, the stability of the power supply is reduced owing to the output volatility of renewable energy. To ensure a high power quality, the system must operate stably. Therefore, only as much variable renewable energy as the system can accommodate should be input. In this study, we developed a methodology to calculate the limit input capacity of solar power generation by considering the power generation and transmission systems. For the power generation system, the minimum constraints of power generation capacity and secondary reserve power were considered. Additionally, line capacity constraints were considered for the transmission system. In other words, a methodology was developed to calculate the limit input capacity of solar power generation that satisfies the three constraints.

14 September 2023 in Preprints.org
Verified
Preprint
Open access
PDF file
HLHyeseon Lee
Hyeseon Lee
BLByungsung Lee
Byungsung Lee
GHGyurim Han
Gyurim Han
YKYuri Kim
Yuri Kim
YKYongha Kim
Yongha Kim
To supply stable and high-quality power according to the advancement of industrial growth, electric power companies have performed maintenance of power facilities using various meth-ods. In the case of domestic power distribution facilities, there are limitations in performing di-agnostic management on all facilities owing to the large number of facilities; therefore, old fa-cilities are managed by the health index assessment method. The health index assessment com-prises only facility operation data and external environmental data and is managed only for four types of distribution facilities, including overhead/underground transformers and switchgear. In the case of extra high–voltage overhead wires, there is no standard for old replacement, despite the large number of wires, such as transformers and switchgear, and the large ripple effect of power failure in the event of a power outage. Therefore, in this paper, a health index assessment methodology for extra-high voltage overhead cables was developed. In this paper, we devel-oped an economic health index assessment methodology that additionally considers risk cost, which is different from the existing health index assessment method that uses only operational data and external environmental data to determine facility performance evaluation and aging replacement criteria. Using the health index assessment methodology developed in this paper, it is possible to expect a reduction in facility operating costs and investment costs from the per-spective of electric power companies through the replacement of old extra-high voltage over-head cables. In addition, from the perspective of consumers, it is expected to increase power re-liability and reduce the ripple effect of failure by preferentially replacing equipment with a high probability of failure.