Nádia Sitoe

Mrs. Nádia Sitoe

Instituto Nacional de Saúde (INS)
orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 June 2023 in PLOS Global Public Health
Verified
Journal Article
Open access
PDF file
NMNelmo Jordão Manjate
Nelmo Jordão Manjate
NSNádia Sitoe
Nádia Sitoe
JSJúlia Sambo
Júlia Sambo
EGEsperança Guimarães
Esperança Guimarães
NCNeide Canana
Neide Canana
GRGiuliano Russo
Giuliano Russo
Early diagnosis of SARS-CoV-2 is fundamental to reduce the risk of community transmission and mortality, as well as public sector expenditures. Three years after the onset of the SARS-CoV-2 pandemic, there are still gaps on what is known regarding costs and cost drivers for the major diagnostic testing strategies in low- middle-income countries (LMICs). This study aimed to estimate the cost of SARS-CoV-2 diagnosis of symptomatic suspected patients by reverse transcription polymerase chain reaction (RT-PCR) and antigen rapid diagnostic tests (Ag-RDT) in Mozambique. We conducted a retrospective cost analysis from the provider’s perspective using a bottom-up, micro-costing approach, and compared the direct costs of two nasopharyngeal Ag-RDTs (Panbio and Standard Q) against the costs of three nasal Ag-RDTs (Panbio, COVIOS and LumiraDx), and RT-PCR. The study was undertaken from November 2020 to December 2021 in the country’s capital city Maputo, in four healthcare facilities at primary, secondary and tertiary levels of care, and at one reference laboratory. All the resources necessary for RT-PCR and Ag-RDT tests were identified, quantified, valued, and the unit costs per test and per facility were estimated. Our findings show that the mean unit cost of SARS-CoV-2 diagnosis by nasopharyngeal Ag-RDTs was MZN 728.00 (USD 11.90, at 2020 exchange rates) for Panbio and MZN 728.00 (USD 11.90) for Standard Q. For diagnosis by nasal Ag-RDTs, Panbio was MZN 547.00 (USD 8.90), COVIOS was MZN 768.00 (USD 12.50), and LumiraDx was MZN 798.00 (USD 13.00). Medical supplies expenditures represented the main driver of the final cost (>50%), followed by personnel and overhead costs (mean 15% for each). The mean unit cost regardless of the type of Ag-RDT was MZN 714.00 (USD 11.60). Diagnosis by RT-PCR cost MZN 2,414 (USD 39.00) per test. Our sensitivity analysis suggests that focussing on reducing medical supplies costs would be the most cost-saving strategy for governments in LMICs, particularly as international prices decrease. The cost of SARS-CoV-2 diagnosis using Ag-RDTs was three times lower than RT-PCR testing. Governments in LMICs can include cost-efficient Ag-RDTs in their screening strategies, or RT-PCR if international costs of such supplies decrease further in the future. Additional analyses are recommended as the costs of testing can be influenced by the sample referral system.

12 February 2022 in Diagnostics
Verified
Journal Article
Open access
PDF file
NSNádia Sitoe
Nádia Sitoe
JAJúlia Sambo Abchande
Júlia Sambo Abchande
NNNeuza Nguenha
Neuza Nguenha
JCJorfelia Jose Chilaule
Jorfelia Jose Chilaule
ICImelda Rogerio Chelene
Imelda Rogerio Chelene
IJIlesh Jani
Ilesh Jani
(1) Background: Laboratory-based molecular assays are the gold standard to detect SARS-CoV-2. In resource-limited settings, the implementation of these assays has been hampered by operational challenges and long turnaround times. Rapid antigen detection tests are an attractive alternative. Our aim is to evaluate the clinical performance of two SARS-CoV-2 rapid antigen tests during a high transmission period. (2) Methods: A total of 1277 patients seeking SARS-CoV-2 diagnosis were enrolled at four health facilities. Nasopharyngeal swabs for rapid antigen and real time PCR testing were collected for each patient. Sensitivity, specificity, positive and negative predictive values, misclassification rate, and agreement were determined. (3) Results: The overall sensitivity of Panbio COVID-19 was 41.3% (95% CI: 34.6–48.4%) and the specificity was 98.2% (95% CI: 96.2–99.3%). The Standard Q had an overall sensitivity and specificity of 45.0% (95% CI: 39.9–50.2%) and 97.6% (95% CI: 95.3–99.0%), respectively. The positive predictive value of a positive test was 93.3% and 95.4% for the Panbio and Standard Q Ag-RDTs, respectively. A higher sensitivity of 43.2% and 49.4% was observed in symptomatic cases for the Panbio and Standard Q Ag-RDTs, respectively. (4) Conclusions: Despite the overall low sensitivity, the two evaluated rapid tests are useful to improve the diagnosis of symptomatic SARS-CoV-2 infections during high transmission periods.

19 September 2022 in Biomedicines
Verified
Journal Article
Open access
PDF file
NSNádia Sitoe
Nádia Sitoe
JAJúlia Sambo Abchande
Júlia Sambo Abchande
NMNédio Mabunda
Nédio Mabunda
NNNeuza Nguenha
Neuza Nguenha
JCJorfélia Chilaúle
Jorfélia Chilaúle
IJIlesh Jani
Ilesh Jani
Background: In resource-poor countries, antigen-based rapid tests (Ag-RDTs) performed at primary healthcare and community settings improved access to SARS-CoV-2 diagnostics. However, the technical skills and biosafety requirements inherent to nasopharyngeal and oropharyngeal (OP) specimens limit the scale-up of SARS-CoV-2 testing. The collection of nasal-swabs is programmatically viable, but its performance has not been evaluated in resource-poor settings. Methods: We first evaluated the performance of SteriPack self-collected nasal swabs for the detection of SARS-CoV-2 by real-time PCR in 1498 consecutively enrolled patients with suspected infection. Next, we evaluated the clinical performance of three nasal swab-based Ag-RDTs against real-time PCR on OP specimens. Results: The sensitivity of nasal swabs was 80.6% [95% CI: 75.3–85.2%] compared to OP specimens. There was a good correlation (r = 0.58; p < 0.0001) between Ct values of 213 positive cases obtained using nasal and OP swabs. Our findings show sensitivities of 79.7% [95% CI: 73.3–85.1%] for Panbio COVID-19 Ag-RDT, 59.6% [95% CI: 55.2–63.8%] for COVIOS Ag-RDT, and 78.0% [95% CI: 73.5–82.0%] for the LumiraDx SARS-CoV-2 Ag-RDT. Conclusions: In our setting, the COVIOS Ag-RDT did not meet WHO requirements. Nasal swab-based Ag-RDTs for SARS-CoV-2 detection constitute a viable and accurate diagnostic option in resource-poor settings.

29 October 2022 in Healthcare
Verified
Journal Article
Open access
PDF file
EAElda Muianga Anapakala
Elda Muianga Anapakala
PCPatrina Chongo
Patrina Chongo
IBIsis da Barca
Isis da Barca
TDTomás Dimas
Tomás Dimas
NSNádia Sitoe
Nádia Sitoe
SVSofia Omar Viegas
Sofia Omar Viegas
WWDISA is an optional module of the DISA Laboratory Information system (LIS) that offers a web portal that allows access to test results over the internet for patient clinical management. This study aims to assess the applicability of using the WWDISA web application, and the lessons learned from its implementation in six health facilities in Mabote district, Inhambane province. Data from 2463 and 665 samples for HIV-viral load (HIVVL) tests, extracted from paper-based and WWDISA systems, respectively, were included, from January to December 2020. Data were simultaneously collected on a quarterly basis from both systems to allow comparison. The WWDISA turnaround time (TAT) from sample collection to results becoming available was found to be 10 (IQR: 8–12) days and significantly lower than the health unit manual logbook (p value < 0.001). Regarding the system efficiency, it was found that among 1978 search results, only 642 (32.5%) were found, and the main challenges according to the users were lack of connectivity (77%) and the website going down (62%). The WWDISA module has been shown to be effective in reducing the TAT, although a stable internet connection and accurate data entry are essential to make the system functional.

12 September 2022 in Pathogens
Verified
Journal Article
Open access
PDF file
NSNádia Sitoe
Nádia Sitoe
MAMohamed I.M. Ahmed
Mohamed I.M. Ahmed
MEMaria Enosse
Maria Enosse
ABAbhishek Bakuli
Abhishek Bakuli
RCRaquel Matavele Chissumba
Raquel Matavele Chissumba
OCon behalf of TB Sequel Consortium
on behalf of TB Sequel Consortium
HIV infection causes systemic immune activation, impacts TB disease progression and hence may influence the diagnostic usability of Mycobacterium tuberculosis-specific T cell profiling. We investigated changes of activation and maturation markers on MTB-specific CD4+ T-cells after anti-tuberculosis treatment initiation in relation to HIV status and the severity of lung impairment. Thawed peripheral blood mononuclear cells from TB patients with (n = 27) and without HIV (n = 17) were analyzed using an intracellular IFN-γ assay and flow cytometry 2 and 6 months post-TB treatment initiation. H37Rv antigen was superior to the profile MTB-specific CD4+ T-cells phenotype when compared to PPD and ESAT6/CFP10. Regardless of HIV status and the severity of lung impairment, activation markers (CD38, HLA-DR and Ki67) on MTB-specific CD4+ T-cells declined after TB treatment initiation (p < 0.01), but the expression of the maturation marker CD27 did not change over the course of TB treatment. The MTB-specific T cell phenotype before, during and after treatment completion was similar between people living with and without HIV, as well as between subjects with severe and mild lung impairment. These data suggest that the assessment of activation and maturation markers on MTB-specific CD4+ T-cells can be useful for TB treatment monitoring, regardless of HIV status and the severity of lung disease.

12 October 2016 in African Journal of Laboratory Medicine
Verified
Journal Article
Open access
PDF file
PCPatrina Chongo
Patrina Chongo
NSNádia Sitoe
Nádia Sitoe
SVSofia Omar Viegas
Sofia Omar Viegas
IPIsabel Pinto
Isabel Pinto
AMAdmiro Macave
Admiro Macave
IJIlesh Jani
Ilesh Jani
Quality assurance for point-of-care testing in Mozambique’s National Health Service