Michele Girardi

Dr. Michele Girardi

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 November 2018 in Physiological Reports
Verified
Journal Article
Open access
PDF file
Andrea NicolòAndrea Nicolò
Andrea Nicolò
MGMichele Girardi
Michele Girardi
IBIlenia Bazzucchi
Ilenia Bazzucchi
FFFelici Francesco
Felici Francesco
Massimo SacchettiMassimo Sacchetti
Massimo Sacchetti
Differentiating between respiratory frequency (fR) and tidal volume (VT) may improve our understanding of exercise hyperpnoea because fR and VT seem to be regulated by different inputs. We designed a series of exercise manipulations to improve our understanding of how fR and VT are regulated during exercise. Twelve cyclists performed an incremental test and three randomized experimental sessions in separate visits. In two of the three experimental visits, participants performed a moderate‐intensity sinusoidal test followed, after recovery, by a moderate‐to‐severe‐intensity sinusoidal test. These two visits differed in the period of the sinusoid (2 min vs. 8 min). In the third experimental visit, participants performed a trapezoidal test where the workload was self‐paced in order to match a predefined trapezoidal template of rating of perceived exertion (RPE). The results collectively reveal that fR changes more with RPE than with workload, gas exchange, VT or the amount of muscle activation. However, fR dissociates from RPE during moderate exercise. Both VT and minute ventilation () showed a similar time course and a large correlation with in all the tests. Nevertheless, was associated more with than with VT because VT seems to adjust continuously on the basis of fR levels to match with . The present findings provide novel insight into the differential control of fR and VT – and their unbalanced interdependence – during exercise. The emerging conceptual framework is expected to guide future research on the mechanisms underlying the long‐debated issue of exercise hyperpnoea.

21 September 2019 in Sport Sciences for Health
Verified
Journal Article
Open access
PDF file
Andrea NicolòAndrea Nicolò
Andrea Nicolò
Massimo SacchettiMassimo Sacchetti
Massimo Sacchetti
MGMichele Girardi
Michele Girardi
AMAlister McCormick
Alister McCormick
LALuca Angius
Luca Angius
SMSamuele M. Marcora
Samuele M. Marcora
Purpose: Despite their widespread use in exercise physiology, time-to-exhaustion (TTE) tests present an often-overlooked challenge to researchers, which is how to computationally deal with between- and within-subject differences in exercise duration. We aimed to verify the best analysis method to overcome this problem. Methods: Eleven cyclists performed an incremental test and three TTE tests differing in workload as preliminary tests. The TTEs were used to derive the individual power–duration relationship needed to set the workload (corresponding to an estimated TTE of 1200 s) for four identical experimental TTE tests. Within individuals, the four tests were subsequently rank ordered by performance. Physiological and psychological variables expected to change with performance were analysed using different methods, with the main aim being to compare the traditional “group isotime” method and a less-used “individual isotime” method. Results: The four tests, ranked from the best to the worst, had a TTE of 1526 ± 332, 1425 ± 313, 1295 ± 325, and 1026 ± 265 s. Ratings of perceived exertion, minute ventilation, respiratory frequency, and affective valence were sensitive to changes in performance when their responses were analysed with the “individual isotime” method (P < 0.022, ηp2 > 0.144) but not when using the “group isotime” method, because the latter resulted in partial data loss. Conclusions: The use of the “individual isotime” method is strongly encouraged to avoid the misinterpretation of the phenomenon under study. Important implications are not limited to constant-workload exercise, but extend to incremental exercise, which is another commonly used test of exercise tolerance.

15 October 2020 in Frontiers in Physiology
Verified
Journal Article
Open access
PDF file
MGMichele Girardi
Michele Girardi
ACAndrea Casolo
Andrea Casolo
SNStefano Nuccio
Stefano Nuccio
CGChiara Gattoni
Chiara Gattoni
CCCarlo Capelli
Carlo Capelli
Detraining Effects Prevention: A New Rising Challenge for Athletes

24 August 2017 in The Journal of Physiology
Verified
Journal Article
Closed access
PDF file
Andrea NicolòAndrea Nicolò
Andrea Nicolò
MGMichele Girardi
Michele Girardi
Massimo SacchettiMassimo Sacchetti
Massimo Sacchetti

15 February 2019 in IEEE Sensors Journal
Verified
Journal Article
Closed access
Carlo MassaroniCarlo Massaroni
Carlo Massaroni
Andrea NicolòAndrea Nicolò
Andrea Nicolò
MGMichele Girardi
Michele Girardi
ACAngelica La Camera
Angelica La Camera
Emiliano SchenaEmiliano Schena
Emiliano Schena
Fabrizio TaffoniFabrizio Taffoni
Fabrizio Taffoni

1 January 2020 in International Journal of Sports Physiology and Performance
Verified
Journal Article
Closed access
Andrea NicolòAndrea Nicolò
Andrea Nicolò
MMMarco Montini
Marco Montini
MGMichele Girardi
Michele Girardi
FFFelici Francesco
Felici Francesco
IBIlenia Bazzucchi
Ilenia Bazzucchi
Massimo SacchettiMassimo Sacchetti
Massimo Sacchetti
Purpose: Variables currently used in soccer training monitoring fail to represent the physiological demand of the player during movements like accelerations, decelerations, and directional changes performed at high intensity. We tested the hypothesis that respiratory frequency (fR) is a marker of physical effort during soccer-related high-intensity exercise. Methods: A total of 12 male soccer players performed a preliminary intermittent incremental test and 2 shuttle-run high-intensity interval training (HIIT) protocols, in separate visits. The 2 HIIT protocols consisted of 12 repetitions over 9 minutes and differed in the work-to-recovery ratio (15:30 vs 30:15 s). Work rate was self-paced by participants to achieve the longest possible total distance in each HIIT protocol. Results: Work-phase average metabolic power was higher (P < .001) in the 15:30-second protocol (31.7 [3.0] W·kg−1) compared with the 30:15-second protocol (22.8 [2.0] W·kg−1). Unlike heart rate and oxygen uptake, fR showed a fast response to the work–recovery alternation during both HIIT protocols, resembling changes in metabolic power even at supramaximal intensities. Large correlations (P < .001) were observed between fR and rating of perceived exertion during both 15:30-second (r = .87) and 30:15-second protocols (r = .85). Conclusions: Our findings suggest that fR is a good marker of physical effort during shuttle-run HIIT in soccer players. These findings have implications for monitoring training in soccer and other team sports.