Fabrizio Taffoni

Prof. Fabrizio Taffoni

Advanced Robotics and Human-Centred Technologies-CREO Lab, Università Campus Bio-Medico di Roma, Rome, Italy
orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 December 2017 in Sensors
Verified
Journal Article
Open access
PDF file
JTJacopo Tosi
Jacopo Tosi
Fabrizio TaffoniFabrizio Taffoni
Fabrizio Taffoni
MSMarco Santacatterina
Marco Santacatterina
RSRoberto Sannino
Roberto Sannino
Domenico FormicaDomenico Formica
Domenico Formica
Small, compact and embedded sensors are a pervasive technology in everyday life for a wide number of applications (e.g., wearable devices, domotics, e-health systems, etc.). In this context, wireless transmission plays a key role, and among available solutions, Bluetooth Low Energy (BLE) is gaining more and more popularity. BLE merges together good performance, low-energy consumption and widespread diffusion. The aim of this work is to review the main methodologies adopted to investigate BLE performance. The first part of this review is an in-depth description of the protocol, highlighting the main characteristics and implementation details. The second part reviews the state of the art on BLE characteristics and performance. In particular, we analyze throughput, maximum number of connectable sensors, power consumption, latency and maximum reachable range, with the aim to identify what are the current limits of BLE technology. The main results can be resumed as follows: throughput may theoretically reach the limit of ~230 kbps, but actual applications analyzed in this review show throughputs limited to ~100 kbps; the maximum reachable range is strictly dependent on the radio power, and it goes up to a few tens of meters; the maximum number of nodes in the network depends on connection parameters, on the network architecture and specific device characteristics, but it is usually lower than 10; power consumption and latency are largely modeled and analyzed and are strictly dependent on a huge number of parameters. Most of these characteristics are based on analytical models, but there is a need for rigorous experimental evaluations to understand the actual limits.

18 October 2013 in Sensors
Verified
Journal Article
Open access
PDF file
Fabrizio TaffoniFabrizio Taffoni
Fabrizio Taffoni
Domenico FormicaDomenico Formica
Domenico Formica
Paola SaccomandiPaola Saccomandi
Paola Saccomandi
GPGiovanni Di Pino
Giovanni Di Pino
Emiliano SchenaEmiliano Schena
Emiliano Schena
During last decades, Magnetic Resonance (MR)—compatible sensors based on different techniques have been developed due to growing demand for application in medicine. There are several technological solutions to design MR-compatible sensors, among them, the one based on optical fibers presents several attractive features. The high elasticity and small size allow designing miniaturized fiber optic sensors (FOS) with metrological characteristics (e.g., accuracy, sensitivity, zero drift, and frequency response) adequate for most common medical applications; the immunity from electromagnetic interference and the absence of electrical connection to the patient make FOS suitable to be used in high electromagnetic field and intrinsically safer than conventional technologies. These two features further heightened the potential role of FOS in medicine making them especially attractive for application in MRI. This paper provides an overview of MR-compatible FOS, focusing on the sensors employed for measuring physical parameters in medicine (i.e., temperature, force, torque, strain, and position). The working principles of the most promising FOS are reviewed in terms of their relevant advantages and disadvantages, together with their applications in medicine.

9 January 2014 in Sensors
Verified
Journal Article
Open access
PDF file
LRLuca Ricci
Luca Ricci
Domenico FormicaDomenico Formica
Domenico Formica
LSLaura Sparaci
Laura Sparaci
FLFrancesca Romana Lasorsa
Francesca Romana Lasorsa
Fabrizio TaffoniFabrizio Taffoni
Fabrizio Taffoni
EGEugenio Guglielmelli
Eugenio Guglielmelli
Recent advances in wearable sensor technologies for motion capture have produced devices, mainly based on magneto and inertial measurement units (M-IMU), that are now suitable for out-of-the-lab use with children. In fact, the reduced size, weight and the wireless connectivity meet the requirement of minimum obtrusivity and give scientists the possibility to analyze children’s motion in daily life contexts. Typical use of magneto and inertial measurement units (M-IMU) motion capture systems is based on attaching a sensing unit to each body segment of interest. The correct use of this setup requires a specific calibration methodology that allows mapping measurements from the sensors’ frames of reference into useful kinematic information in the human limbs’ frames of reference. The present work addresses this specific issue, presenting a calibration protocol to capture the kinematics of the upper limbs and thorax in typically developing (TD) children. The proposed method allows the construction, on each body segment, of a meaningful system of coordinates that are representative of real physiological motions and that are referred to as functional frames (FFs). We will also present a novel cost function for the Levenberg–Marquardt algorithm, to retrieve the rotation matrices between each sensor frame (SF) and the corresponding FF. Reported results on a group of 40 children suggest that the method is repeatable and reliable, opening the way to the extensive use of this technology for out-of-the-lab motion capture in children.

2 January 2014 in Sensors
Verified
Journal Article
Open access
PDF file
ETEleonora Tamilia
Eleonora Tamilia
Fabrizio TaffoniFabrizio Taffoni
Fabrizio Taffoni
Domenico FormicaDomenico Formica
Domenico Formica
LRLuca Ricci
Luca Ricci
Emiliano SchenaEmiliano Schena
Emiliano Schena
EGEugenio Guglielmelli
Eugenio Guglielmelli
Nutritive Sucking (NS) is a highly organized process that is essential for infants’ feeding during the first six months of their life. It requires the complex coordination of sucking, swallowing and breathing. The infant’s inability to perform a safe and successful oral feeding can be an early detector of immaturity of the Central Nervous System (CNS). Even though the importance of early sucking measures has been confirmed over the years, the need for standardized instrumental assessment tools still exists. Clinicians would benefit from specifically designed devices to assess oral feeding ability in their routine clinical monitoring and decision-making process. This work is a review of the main instrumental solutions developed to assess an infant’s NS behavior, with a detailed survey of the main quantities and indices measured and/or estimated to characterize sucking behavior skills and their development. The adopted sensing measuring systems will be described, and their main advantages and weaknesses will be discussed, taking into account their application to clinical practice, or to at-home monitoring as post-discharge assessment tools. Finally, the study will highlight the most suitable sensing solutions and give some prompts for further research.

13 May 2016 in Frontiers in Psychology
Verified
Journal Article
Open access
PDF file
VFValentina Focaroli
Valentina Focaroli
Fabrizio TaffoniFabrizio Taffoni
Fabrizio Taffoni
SPShelby M. Parsons
Shelby M. Parsons
FKFlavio Keller
Flavio Keller
JIJana M Iverson
Jana M Iverson
Recent research shows that motor difficulties are a prominent component of the behavioral profile of autism spectrum disorder (ASD) and are also apparent from early in development in infants who have an older sibling with ASD (High Risk; HR). Delays have been reported for HR infants who do and who do not receive an eventual diagnosis of ASD. A growing body of prospective studies has focused on the emergence of early motor skills primarily during the first year of life. To date, however, relatively little work has examined motor skills in the second and third years. Thus, the present research was designed to investigate motor performance in object transport tasks longitudinally in HR and LR (Low Risk) children between the ages of 18 and 36 months. Participants (15 HR children and 14 LR children) were observed at 18, 24, and 36 months. Children completed two motor tasks, the Ball Task and the Block Task, each of which included two conditions that varied in terms of the precision demands of the goal action. Kinematic data were acquired via two magneto inertial sensors worn on each wrist. In the Block Task, HR children reached more slowly (i.e., mean acceleration was lower) compared to LR children. This finding is in line with growing evidence of early delays in fine motor skills in HR children and suggests that vulnerabilities in motor performance may persist into the preschool years in children at risk for ASD.

15 February 2019 in IEEE Sensors Journal
Verified
Journal Article
Closed access
Carlo MassaroniCarlo Massaroni
Carlo Massaroni
Andrea NicolòAndrea Nicolò
Andrea Nicolò
MGMichele Girardi
Michele Girardi
ACAngelica La Camera
Angelica La Camera
Emiliano SchenaEmiliano Schena
Emiliano Schena
Fabrizio TaffoniFabrizio Taffoni
Fabrizio Taffoni