Andrzej Za̧bek

Dr. Andrzej Za̧bek

Department of Electrocardiology, John Paul II Hospital, Krakow, Poland
orcid

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 October 2018 in The International Journal of Cardiovascular Imaging
Verified
Journal Article
Open access
PDF file
KHKatarzyna Holcman
Katarzyna Holcman
WSWojciech Szot
Wojciech Szot
Paweł RubiśPaweł Rubiś
Paweł Rubiś
ALAgata Leśniak-Sobelga
Agata Leśniak-Sobelga
MHMarta Hlawaty
Marta Hlawaty
MKMagdalena Kostkiewicz
Magdalena Kostkiewicz
Infective endocarditis (IE) is a life-threatening disease, establishing a diagnosis is often challenging. The aim of this prospective study was to evaluate and compare the diagnostic performance of the combined use of single photon emission tomography and computed tomography with technetium99m-hexamethylpropyleneamineoxime—labeled leukocytes (99mTc-HMPAO-SPECT/CT) with transthoracic echocardiography (TTE) in patients with suspected IE. We enrolled 40 consecutive patients (12 females, 28 males, mean age: 58.6 ± 18) with suspected IE in the years 2015–2016. All patients underwent clinical evaluation, TTE and 99mTc-HMPAO-SPECT/CT for the assessment of lesions typical for IE. Scans were evaluated for the presence and location of increased radioactivity foci, corresponding to the accumulation of radiolabeled leukocytes in inflammatory lesions. After 6 months, the patients were re-evaluated clinically and with TTE. Final IE diagnosis was established in 14 (35%) patients. Lesions typical for IE were shown in 28 (70%) TTEs and 16 (40%) 99mTc-HMPAO-SPECT/CTs. The latter tests were characterized by 90% accuracy, 93% sensitivity, 88% specificity, 96% negative predictive value (NPV), 81% positive predictive value (PPV). TTE demonstrated 60% accuracy, 93% sensitivity, 42% specificity, 92% NPV, and 46% PPV. 99mTc-HMPAO-SPECT/CT was characterized by a lower number of false-positive results compared to TTE (3 vs. 15). In patients with suspected IE, 99mTc-HMPAO-SPECT/CT yields a smaller number of false-positive results, significantly higher diagnostic accuracy, specificity and PPV than TTE. It helps to differentiate IE infectious and sterile echocardiographic lesions and reduces by 27% the number of misdiagnosed IE classified in the ‘possible IE’ category by modified Duke Criteria.

19 January 2019 in Pacing and Clinical Electrophysiology
Verified
Journal Article
Closed access
PDF file
KBKrzysztof Boczar
Krzysztof Boczar
ASAgnieszka Slawuta
Agnieszka Slawuta
AZAndrzej Za̧bek
Andrzej Za̧bek
MDMaciej Debski
Maciej Debski
PVPugazhendhi Vijayaraman
Pugazhendhi Vijayaraman
BMBarbara Małecka
Barbara Małecka

14 December 2021 in Scientific Reports
Verified
Journal Article
Open access
PDF file
Paweł RubiśPaweł Rubiś
Paweł Rubiś
EDEwa M. Dziewięcka
Ewa M. Dziewięcka
PBPaweł Banyś
Paweł Banyś
MUMałgorzata Urbańczyk-Zawadzka
Małgorzata Urbańczyk-Zawadzka
MKMaciej Krupiński
Maciej Krupiński
AGAnn C. Garlitski
Ann C. Garlitski
The current stratification of arrhythmic risk in dilated cardiomyopathy (DCM) is sub-optimal. Cardiac fibrosis is involved in the pathology of arrhythmias; however, the relationship between cardiovascular magnetic resonance (CMR) derived extracellular volume (ECV) and arrhythmic burden (AB) in DCM is unknown. This study sought to evaluate the presence and extent of replacement and interstitial fibrosis in DCM and to compare the degree of fibrosis between DCM patients with and without AB. This is a prospective, single-center, observational study. Between May 2019 and September 2020, 102 DCM patients underwent CMR T1 mapping. 99 DCM patients (88 male, mean age 45.2 ± 11.8 years, mean EF 29.7 ± 10%) composed study population. AB was defined as the presence of VT or a high burden of PVCs. There were 41 (41.4%) patients with AB and 58 (58.6%) without AB. Replacement fibrosis was assessed with late gadolinium enhancement (LGE), whereas interstitial fibrosis with ECV. Overall, LGE was identified in 41% of patients. There was a similar distribution of LGE (without AB 50% vs. with AB 53.7%;p = 0.8) and LGE extent (without AB 4.36 ± 5.77% vs. with AB 4.68 ± 3.98%;p = 0.27) in both groups. ECV at nearly all myocardial segments and a global ECV were higher in patients with AB (global ECV: 27.9 ± 4.9 vs. 30.3 ± 4.2;p < 0.02). Only indexed left ventricular end-diastolic diameter (HR 1.1, 95%CI 1.0–1.2;p < 0.02) and global ECV (HR 1.12, 95%CI 1.0–1.25;p < 0.02) were independently associated with AB. The global ECV cut-off value of 31.05% differentiated both groups (AUC 0.713; 95%CI 0.598–0.827;p < 0.001). Neither qualitative nor quantitative LGE-based assessment of replacement fibrosis allowed for the stratification of DCM patients into low or high AB. Interstitial fibrosis, expressed as ECV, was an independent predictor of AB in DCM. Incorporation of CMR parametric indices into decision-making processes may improve arrhythmic risk stratification in DCM.

12 October 2019 in European Heart Journal - Cardiovascular Imaging
Verified
Journal Article
Closed access
KHKatarzyna Holcman
Katarzyna Holcman
BMBarbara Małecka
Barbara Małecka
PRPaweł Rubiś
Paweł Rubiś
AZAndrzej Za̧bek
Andrzej Za̧bek
WSWojciech Szot
Wojciech Szot
MKMagdalena Kostkiewicz
Magdalena Kostkiewicz
Aims: The hybrid technique of single-photon emission tomography and computed tomography with technetium99m-hexamethylpropyleneamine oxime–labelled leucocytes (99mTc-HMPAO-SPECT/CT) is an emerging diagnostic technique in patients with cardiac device-related infective endocarditis (CDRIE). This prospective study assessed the 99mTc-HMPAO-SPECT/CT diagnostic profile and its added value to the modified Duke criteria (mDuke) in CDRIE diagnostic work-up. Methods and results: The study examined 103 consecutive patients with suspected CDRIE, who underwent 99mTc-HMPAO-SPECT/CT. Diagnostic accuracy was calculated based on a final clinical CDRIE diagnosis, including microbiology, echocardiography, and a 6-month follow-up. Subsequently, we compared the diagnostic value of the initial mDuke classification with a classification including 99mTc-HMPAO-SPECT/CT positive results as an additional major CDRIE criterion: mDuke-SPECT/CT. Overall, CDRIE was diagnosed in 31 (31%) patients, whereas 35 (34%) 99mTc-HMPAO-SPECT/CT were positive. 99mTc-HMPAO-SPECT/CT was characterized by 86% accuracy, 0.69 Cohen’s kappa coefficient, 84% sensitivity, 88% specificity, 93% negative, and 74% positive predictive values. The original mDuke displayed 83% accuracy, 0.52 kappa, whereas mDuke-SPECT/CT had 88% accuracy, and 0.73 kappa. Compared with mDuke, mDuke-SPECT/CT showed significantly higher sensitivity (87% vs. 48%, P < 0.001). According to mDuke, 49.5% of patients had possible CDRIE, and after reclassification, that figure dropped to 37%. Furthermore, having assessed the diagnosis categorization improvement following the incorporation of 99mTc-HMPAO-SPECT/CT, the net reclassification index value was found to be 31.4%. Conclusion: In patients with CDRIE, 99mTc-HMPAO-SPECT/CT provides high diagnostic accuracy, whereas a negative scan excludes CDRIE with high probability. Inclusion of 99mTc-HMPAO-SPECT/CT into mDuke diagnostic criteria yields significantly higher sensitivity and a reduction in possible CDRIE diagnoses.

20 January 2023 in EP Europace
Verified
Journal Article
Open access
PDF file
AZAndrzej Za̧bek
Andrzej Za̧bek
KBKrzysztof Boczar
Krzysztof Boczar
MUMateusz Ulman
Mateusz Ulman
KHKatarzyna Holcman
Katarzyna Holcman
MKMagdalena Kostkiewicz
Magdalena Kostkiewicz
BMBarbara Małecka
Barbara Małecka
To analyze and compare the effectiveness and safety of transvenous lead extraction (TLE) of implantable cardioverter-defibrillator (ICD) leads with a dwell time of >10 years (Group A) vs. younger leads (Group B) using mechanical extraction systems. Between October 2011 and July 2022, we performed TLE in 318 patients. Forty-six (14.4%) extracted ICD leads in 46 (14.5%) patients that had been implanted for >10 years. The median dwell time of all extracted ICD leads was 5.9 years. Cardiovascular implantable electronic device-related infection was an indication for TLE in 31.8% of patients. Complete ICD leads removal and complete procedural success in both groups were similar (95.7% in Group A vs. 99.6% in Group B, P = 0.056% and 95.6% in Group A vs. 99.6% in Group B, P = 0.056, respectively). We did not find a significant difference between major and minor complication rates in both groups (6.5% in Group A vs. 1.5% in Group B and 2.2% in Group A vs. 1.8% in Group B, P = 0.082, respectively). One death associated with the TLE procedure was recorded in Group B. The TLE procedures involving the extraction of old ICD leads were effective and safe. The outcomes of ICD lead removal with a dwell time of >10 years did not differ significantly compared with younger ICD leads. However, extraction of older ICD leads required more frequent necessity for utilizing multiple extraction tools, more experience and versatility of the operator, and increased surgery costs.

13 February 2014 in Cardiology Journal
Verified
Journal Article
Open access
AKAndrzej Kutarski
Andrzej Kutarski
APAnna Polewczyk
Anna Polewczyk
KBKrzysztof Boczar
Krzysztof Boczar
AZAndrzej Za̧bek
Andrzej Za̧bek
MPMaciej Polewczyk
Maciej Polewczyk
There is a considerable controversy regarding safety of transvenous lead extraction (TLE) in elderly patients due to their potentially worse general condition, more concomitant diseases, more difficult sedation or analgesia. Moreover, the present experience is not relevant. The aim of the study was the comparison of safety and feasibility of TLE in elderly and middle-aged patients. We have extracted an ingrown pacemaker (PM)/implantable cardioverter-defibrillator (ICD) leads from 1,060 adult patients (21-70 years) and 192 octogenarians (mean age 83.4 ± 3.1 years) using standard mechanical systems within the last 7 years. We compared effectiveness and complications of the TLE procedures in the two mentioned groups of patients. There were more women in octogenarians referred for TLE (45.3% vs. 36.9%). In addition, more pocket infections (37.0% vs. 24.5%), less non-infective indications for PM (46.9% vs. 57.7%) and ICD systems (7.3% vs. 28.8%) TLE were observed in this group. Leads body dwelling time was similar (76.4 ± 56.8 vs. 83.5 ± 63.0) in both groups. Procedure efficacy (full radiological success 97.4% vs. 94.6%, partial radiological success 2.6% vs. 4.34%), safety measures (major complications 1.6% vs. 1.51%, minor complications 1.0% vs. 1.9%) were similar in both compared groups. Old age does not influence TLE effectiveness. Therefore, TLE can be safely and successfully performed in octogenarians.