Krzysztof Boczar

Krzysztof Boczar

Auto-generated profile, based on publicly available information

Krzysztof Boczar

Department of Electrocardiology, The St. John Paul II Hospital, Kraków, Poland

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 January 2019 in Pacing and Clinical Electrophysiology
Verified
Journal Article
Closed access
PDF file
KBKrzysztof Boczar
Krzysztof Boczar
ASAgnieszka Slawuta
Agnieszka Slawuta
AZAndrzej Za̧bek
Andrzej Za̧bek
MDMaciej Debski
Maciej Debski
PVPugazhendhi Vijayaraman
Pugazhendhi Vijayaraman
BMBarbara Małecka
Barbara Małecka

20 January 2023 in EP Europace
Verified
Journal Article
Open access
PDF file
AZAndrzej Za̧bek
Andrzej Za̧bek
KBKrzysztof Boczar
Krzysztof Boczar
MUMateusz Ulman
Mateusz Ulman
KHKatarzyna Holcman
Katarzyna Holcman
MKMagdalena Kostkiewicz
Magdalena Kostkiewicz
BMBarbara Małecka
Barbara Małecka
To analyze and compare the effectiveness and safety of transvenous lead extraction (TLE) of implantable cardioverter-defibrillator (ICD) leads with a dwell time of >10 years (Group A) vs. younger leads (Group B) using mechanical extraction systems. Between October 2011 and July 2022, we performed TLE in 318 patients. Forty-six (14.4%) extracted ICD leads in 46 (14.5%) patients that had been implanted for >10 years. The median dwell time of all extracted ICD leads was 5.9 years. Cardiovascular implantable electronic device-related infection was an indication for TLE in 31.8% of patients. Complete ICD leads removal and complete procedural success in both groups were similar (95.7% in Group A vs. 99.6% in Group B, P = 0.056% and 95.6% in Group A vs. 99.6% in Group B, P = 0.056, respectively). We did not find a significant difference between major and minor complication rates in both groups (6.5% in Group A vs. 1.5% in Group B and 2.2% in Group A vs. 1.8% in Group B, P = 0.082, respectively). One death associated with the TLE procedure was recorded in Group B. The TLE procedures involving the extraction of old ICD leads were effective and safe. The outcomes of ICD lead removal with a dwell time of >10 years did not differ significantly compared with younger ICD leads. However, extraction of older ICD leads required more frequent necessity for utilizing multiple extraction tools, more experience and versatility of the operator, and increased surgery costs.

2 May 2019 in Pacing and Clinical Electrophysiology
Verified
Journal Article
Closed access
PDF file
AZAndrzej Za̧bek
Andrzej Za̧bek
KBKrzysztof Boczar
Krzysztof Boczar
MDMaciej Debski
Maciej Debski
PMPaweł Tomasz Matusik
Paweł Tomasz Matusik
RPRoman Pfitzner
Roman Pfitzner
BMBarbara Małecka
Barbara Małecka

2 January 2017 in Acta Cardiologica
Verified
Journal Article
Closed access
KBKrzysztof Boczar
Krzysztof Boczar
AZAndrzej Za̧bek
Andrzej Za̧bek
KHKazimierz Haberka
Kazimierz Haberka
MDMaciej Debski
Maciej Debski
ARAnna Rydlewska
Anna Rydlewska
BMBarbara Malecka
Barbara Malecka
Objective The aim of this study was to evaluate the incidence of venous stenosis and occlusion (VSO) in patients referred for transvenous lead extraction (TLE) with regard to the indications for this treatment and to analyse the influence of VSO on efficacy, complications and technical challenges of TLE procedures. Methods The material consists of 133 consecutive TLE procedure records. The contrast venography examination of the ipsilateral access vein was performed prior to the operation. The whole study population was divided into two subgroups, based on the presence (subgroup I) or absence (subgroup II) of VSO. Results Phlebography was performed in 133 patients with age ranging from 25.7 to 86.1 years, 44 female (33.1%). The VSO was confirmed in 48 (36.1%) patients – subgroup I. Most of the patients were referred to TLE due to non-infectious reasons (100 pts—75.2%). The absence of VSO was observed substantially more frequently in patients with diabetes (P = 0.02). Procedural success rate reached 93.3% in subgroup I and 98.8% in subgroup II (P = 0.1). There was no significant difference in the use of advanced tools and alternative access sites. Conclusion The presence of VSO can be expected in one third of patients referred for lead extraction. There is no association between indication for TLE (infected or noninfected lead extraction) and the incidence of VSO. Diabetes proved to have a protective effect on venous patency in the previously mentioned group. VSO does not influence the effectiveness, safety, and the use of additional tools during TLE procedures.

12 February 2023 in Vaccines
Verified
Journal Article
Open access
PDF file
KHKatarzyna Holcman
Katarzyna Holcman
Paweł RubiśPaweł Rubiś
Paweł Rubiś
AZAndrzej Za̧bek
Andrzej Za̧bek
KBKrzysztof Boczar
Krzysztof Boczar
PPPiotr Podolec
Piotr Podolec
MKMagdalena Kostkiewicz
Magdalena Kostkiewicz
Infective endocarditis (IE) is a growing epidemiological challenge. Appropriate diagnosis remains difficult due to heterogenous etiopathogenesis and clinical presentation. The disease may be followed by increased mortality and numerous diverse complications. Developing molecular imaging modalities may provide additional insights into ongoing infection and support an accurate diagnosis. We present the current evidence for the diagnostic performance and indications for utilization in current guidelines of the hybrid modalities: single photon emission tomography with technetium99m-hexamethylpropyleneamine oxime–labeled autologous leukocytes (99mTc-HMPAO-SPECT/CT) along with positron emission tomography with fluorodeoxyglucose (18F-FDG PET/CT). The role of molecular imaging in IE diagnostic work-up has been constantly growing due to technical improvements and the increasing evidence supporting its added diagnostic and prognostic value. The various underlying molecular processes of 99mTc-HMPAO-SPECT/CT as well as 18F-FDG PET/CT translate to different imaging properties, which should be considered in clinical practice. Both techniques provide additional diagnostic value in the assessment of patients at risk of IE. Nuclear imaging should be considered in the IE diagnostic algorithm, not only for the insights gained into ongoing infection at a molecular level, but also for the determination of the optimal clinical therapeutic strategies.

28 July 2018 in Pacing and Clinical Electrophysiology
Verified
Journal Article
Closed access
PDF file
AZAndrzej Za̧bek
Andrzej Za̧bek
KBKrzysztof Boczar
Krzysztof Boczar
MDMaciej Debski
Maciej Debski
MUMateusz Ulman
Mateusz Ulman
PMPaweł Tomasz Matusik
Paweł Tomasz Matusik
BMBarbara Małecka
Barbara Małecka