Eun-Bin Bae

Dr. Eun-Bin Bae

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
JSJin-Hyung Shim
Jin-Hyung Shim
JWJoo-Yun Won
Joo-Yun Won
JPJung-Hyung Park
Jung-Hyung Park
DDDddd Dddd
Dddd Dddd
GAGeunseon Ahn
Geunseon Ahn
JHJung-Bo Huh
Jung-Bo Huh
This study was conducted to compare 3D-printed polycaprolactone (PCL) and polycaprolactone/β-tricalcium phosphate (PCL/β-TCP) membranes with a conventional commercial collagen membrane in terms of their abilities to facilitate guided bone regeneration (GBR). Fabricated membranes were tested for dry and wet mechanical properties. Fibroblasts and preosteoblasts were seeded into the membranes and rates and patterns of proliferation were analyzed using a kit-8 assay and by scanning electron microscopy. Osteogenic differentiation was verified by alizarin red S and alkaline phosphatase (ALP) staining. An in vivo experiment was performed using an alveolar bone defect beagle model, in which defects in three dogs were covered with different membranes. CT and histological analyses at eight weeks after surgery revealed that 3D-printed PCL/β-TCP membranes were more effective than 3D-printed PCL, and substantially better than conventional collagen membranes in terms of biocompatibility and bone regeneration and, thus, at facilitating GBR.

15 December 2017 in Biomedical Materials
Verified
Journal Article
Closed access
PDF file
JSJin-Hyung Shim
Jin-Hyung Shim
JJJae-Hyang Jeong
Jae-Hyang Jeong
JWJoo-Yun Won
Joo-Yun Won
JBJi-Hyeon Bae
Ji-Hyeon Bae
GAGeunseon Ahn
Geunseon Ahn
JHJung-Bo Huh
Jung-Bo Huh
The appropriate porosity and pore size of barrier membranes were associated with the transportation of biomolecules required for new bone formation and angiogenesis. In this study, we fabricated three-dimensional (3D)-printed resorbable polycaprolactone (PCL) membranes with different porosities (30%, 50%, and 70%) to evaluate the effective pore size for guided bone regeneration (GBR) membranes. To analyze mechanical properties and cytocompatibility, PCL membranes prepared using extrusion-based 3D printing technology were compared in dry and wet conditions and tested in vitro . The proliferation rates and pattern of fibroblasts and preosteoblasts on PCL membranes with different porosities were determined using a cell counting kit-8 assay and scanning electron microscopy. PCL membrane porosity did not affect cell proliferation, but osteogenic differentiation and mechanical properties were increased with lower porosity (30%) on day 14 ( p < 0.001). Similar results were found in an in vivo calvarial defect model; new bone formation was significantly higher in PCL membranes with lower porosity ( p < 0.001). These results indicate that 3D-printed PCL with 30% porosity (130 μ m pore size) is an excellent pore size for GBR membranes.

Verified
Journal Article
Open access
PDF file
JKJeong-Woo Kim
Jeong-Woo Kim
YSYong Cheol Shin
Yong Cheol Shin
JLJin-Ju Lee
Jin-Ju Lee
EBEun-Bin Bae
Eun-Bin Bae
YJYoung-Chan Jeon
Young-Chan Jeon
JHJung-Bo Huh
Jung-Bo Huh
This study was conducted to evaluate the effect of biphasic calcium phosphate (BCP) coated with reduced graphene oxide (rGO) as bone graft materials on bone regeneration. The rGO-coated BCP bone graft material was fabricatied by mixing rGO and BCP at various concentrations. The surface charge of rGO-coated BCP was measured to be −14.43 mV, which formed a static electrostatic interaction. Cell viabilities were significantly diminished at higher concentrations of ≥100 μg/mL. The calvarial defects of 48 rats were implanted rGO-coated BCPs at a weight ratio of 2:1000 (rGO2), 4:1000 (rGO4), and 10:1000 (rGO10), repectively. BCP was used as a control group. The micro-CT and histological analysis were performed to evaluate new bone formation at 2 and 8 weeks after surgery. The results showed that the new bone volume (mm3) was significantly higher in the experimental groups than in the control group. Histological analysis showed that new bone areas (%) were significantly higher in the rGO2 and rGO10 than in the control, and significantly higher in rGO4 than in the rGO2 and rGO10. Conclusively, the rGO-coated BCP was found to be effective on osteogenesis and the concentration of the composite was an important factor.

1 January 2017 in BioMed Research International
Verified
Journal Article
Open access
PDF file
EBEun-Bin Bae
Eun-Bin Bae
SKSeong-Jong Kim
Seong-Jong Kim
JCJae-Won Choi
Jae-Won Choi
YJYoung-Chan Jeon
Young-Chan Jeon
CJChang-Mo Jeong
Chang-Mo Jeong
JHJung-Bo Huh
Jung-Bo Huh
This study was performed to make comparative analysis of the clinical findings between the two different types of the implant-assisted removable partial dentures: removable partial dentures using implant surveyed bridge as an abutment (ISBRPD) and overdenture type of removable partial denture using implant attachment (IARPD). Implant cumulative survival rate, marginal bone resorption, probing depth, peri-implant inflammation, bleeding, plaque, calculus, and complications were evaluated on 24 patients who were treated with implants in conjunction with removable partial denture and have used them for at least 1 year (ISCRPD: n=12; IARPD: n=12). There was no failed implant and all implants were functioning without clinical mobility. Marginal bone loss of ISCRPD (1.44 ± 0.57 mm) was significantly lower than that of IARPD (p<0.05). There was no significant difference in probing depth, peri-implant inflammation, bleeding, and plaque between the two groups (p>0.05), while the calculus was significantly more observed in ISCRPD group than in IARPD group (p<0.05). The retention loss of IARPD was the most common complication. Within the limits of the present study, it was found that well-planned ISBRPD was clinically appropriate. Longitudinal and systematic clinical studies are necessary to confirm these results.

12 October 2019 in Materials
Verified
Journal Article
Open access
PDF file
DKDae-Sung Kim
Dae-Sung Kim
JAJong-Ju Ahn
Jong-Ju Ahn
EBEun-Bin Bae
Eun-Bin Bae
GKGyoo-Cheon Kim
Gyoo-Cheon Kim
CJChang-Mo Jeong
Chang-Mo Jeong
SLSo-Hyoun Lee
So-Hyoun Lee
The purpose of this study was to evaluate the effect of non-thermal atmospheric pressure plasma (NTP) on shear bond strength (SBS) between yttria-stabilized tetragonal zirconia polycrystal (Y-TZP) and self-adhesive resin cement. For this study, surface energy (SE) was calculated with cube-shaped Y-TZP specimens, and SBS was measured on disc-shaped Y-TZP specimens bonded with G-CEM LinkAce or RelyX U200 resin cylinder. The Y-TZP specimens were classified into four groups according to the surface treatment as follows: Control (no surface treatment), NTP, Sb (Sandblasting), and Sb + NTP. The results showed that the SE was significantly higher in the NTP group than in the Control group (p < 0.05). For the SBS test, in non-thermocycling, the NTP group of both self-adhesive resin cements showed significantly higher SBS than the Control group (p < 0.05). However, regardless of the cement type in thermocycling, there was no significant increase in the SBS between the Control and NTP groups. Comparing the two cements, regardless of thermocycling, the NTP group of G-CEM LinkAce showed significantly higher SBS than that of RelyX U200 (p < 0.05). Our study suggests that NTP increases the SE. Furthermore, NTP increases the initial SBS, which is higher when using G-CEM LinkAce than when using RelyX U200.

27 February 2018 in BioMed Research International
Verified
Journal Article
Open access
PDF file
EBEun-Bin Bae
Eun-Bin Bae
KPKeun-Ho Park
Keun-Ho Park
JSJin-Hyung Shim
Jin-Hyung Shim
HCHo-Yun Chung
Ho-Yun Chung
JCJae-Won Choi
Jae-Won Choi
JHJung-Bo Huh
Jung-Bo Huh
This study was undertaken to evaluate the effect of 3D printed polycaprolactone (PCL)/β-tricalcium phosphate (β-TCP) scaffold containing bone demineralized and decellularized extracellular matrix (bdECM) and human recombinant bone morphogenetic protein-2 (rhBMP-2) on bone regeneration. Scaffolds were divided into PCL/β-TCP, PCL/β-TCP/bdECM, and PCL/β-TCP/bdECM/BMP groups. In vitro release kinetics of rhBMP-2 were determined with respect to cell proliferation and osteogenic differentiation. These three reconstructive materials were implanted into 8 mm diameter calvarial bone defect in male Sprague-Dawley rats. Animals were sacrificed four weeks after implantation for micro-CT, histologic, and histomorphometric analyses. The findings obtained were used to calculate new bone volumes (mm3) and new bone areas (%). Excellent cell bioactivity was observed in the PCL/β-TCP/bdECM and PCL/β-TCP/bdECM/BMP groups, and new bone volume and area were significantly higher in the PCL/β-TCP/bdECM/BMP group than in the other groups (p<.05). Within the limitations of this study, bdECM printed PCL/β-TCP scaffolds can reproduce microenvironment for cells and promote adhering and proliferating the cells onto scaffolds. Furthermore, in the rat calvarial defect model, the scaffold which printed rhBMP-2 loaded bdECM stably carries rhBMP-2 and enhances bone regeneration confirming the possibility of bdECM as rhBMP-2 carrier.