Dddd Dddd

Dr. Dddd Dddd


Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
JSJin-Hyung Shim
Jin-Hyung Shim
JWJoo-Yun Won
Joo-Yun Won
JPJung-Hyung Park
Jung-Hyung Park
DDDddd Dddd
Dddd Dddd
GAGeunseon Ahn
Geunseon Ahn
JHJung-Bo Huh
Jung-Bo Huh
This study was conducted to compare 3D-printed polycaprolactone (PCL) and polycaprolactone/β-tricalcium phosphate (PCL/β-TCP) membranes with a conventional commercial collagen membrane in terms of their abilities to facilitate guided bone regeneration (GBR). Fabricated membranes were tested for dry and wet mechanical properties. Fibroblasts and preosteoblasts were seeded into the membranes and rates and patterns of proliferation were analyzed using a kit-8 assay and by scanning electron microscopy. Osteogenic differentiation was verified by alizarin red S and alkaline phosphatase (ALP) staining. An in vivo experiment was performed using an alveolar bone defect beagle model, in which defects in three dogs were covered with different membranes. CT and histological analyses at eight weeks after surgery revealed that 3D-printed PCL/β-TCP membranes were more effective than 3D-printed PCL, and substantially better than conventional collagen membranes in terms of biocompatibility and bone regeneration and, thus, at facilitating GBR.

21 March 2022 in Biomaterials Research
Verified
Journal Article
Open access
PDF file
YSYong Cheol Shin
Yong Cheol Shin
DDDddd Dddd
Dddd Dddd
JLJong Ho Lee
Jong Ho Lee
Selestin Raja Iruthaya PandiSelestin Raja Iruthaya Pandi
Selestin Raja Iruthaya Pandi
MKMoon Sung Kang
Moon Sung Kang
Dong-Wook HanDong-Wook Han
Dong-Wook Han
Background: The implants of pure titanium (Ti) and its alloys can lead to implant failure because of their poor interaction with bone-associated cells during bone regeneration. Surface modification over implants has achieved successful implants for enhanced osseointegration. Herein, we report a robust strategy to implement bioactive surface modification for implant interface enabled by the combinatorial system of reduced graphene oxide (rGO)-coated sandblasted, large-grit, and acid-etched (SLA) Ti to impart benefits to the implant. Methods: We prepared SLA Ti (ST) implants with different surface modifications [i.e., rGO and recombinant human bone morphogenetic protein-2 (rhBMP-2)] and investigated their dental tissue regenerating ability in animal models. We performed comparative studies in surface property, in vitro cellular behaviors, and in vivo osseointegration activity among different groups, including ST (control), rhBMP-2-immobilized ST (BI-ST), rhBMP-2-treated ST (BT-ST), and rGO-coated ST (R-ST). Results: Spectroscopic, diffractometric, and microscopic analyses confirmed that rGO was coated well around the surfaces of Ti discs (for cell study) and implant fixtures (for animal study). Furthermore, in vitro and in vivo studies revealed that the R-ST group showed significantly better effects in cell attachment and proliferation, alkaline phosphatase activity, matrix mineralization, expression of osteogenesis-related genes and protein, and osseointegration than the control (ST), BI-ST, and BT-ST groups. Conclusion: Hence, we suggest that the rGO-coated Ti can be a promising candidate for the application to dental or even orthopedic implants due to its ability to accelerate the healing rate with the high potential of osseointegration.

1 January 2017 in Materials
Verified
Journal Article
Open access
PDF file
HYHyun-Sang Yoo
Hyun-Sang Yoo
DDDddd Dddd
Dddd Dddd
SKSe-Eun Kim
Se-Eun Kim
EBEun-Bin Bae
Eun-Bin Bae
SKSo-Yeun Kim
So-Yeun Kim
JHJung-Bo Huh
Jung-Bo Huh
In this study, bisphasic calcium phosphate (BCP) and two types of polysaccharide, carboxymethyl cellulose (CMC) and hyaluronic acid (HyA), were used to fabricate composite block bone grafts, and their physical and biological features and performances were compared and evaluated in vitro and in vivo. Specimens of the following were prepared as 6 mm diameter, 2 mm thick discs; BPC mixed with CMC (the BCP/CMC group), BCP mixed with crosslinked CMC (the BCP/c-CMC group) and BCP mixed with HyA (the BCP/HyA group) and a control group (specimens were prepared using particle type BCP). A scanning electron microscope study, a compressive strength analysis, and a cytotoxicity assessment were conducted. Graft materials were implanted in each of four circular defects of 6 mm diameter in calvarial bone in seven rabbits. Animals were sacrificed after four weeks for micro-CT and histomorphometric analyses, and the findings obtained were used to calculate new bone volumes (mm3) and area percentages (%). It was found that these two values were significantly higher in the BCP/c-CMC group than in the other three groups (p < 0.05). Within the limitations of this study, BCP composite block bone graft material incorporating crosslinked CMC has potential utility when bone augmentation is needed.

27 October 2023 in Polymers
Verified
Journal Article
Open access
PDF file
Soyoung ParkSoyoung Park
Soyoung Park
WCWon-Tak Cho
Won-Tak Cho
Hyeonjong LeeHyeonjong Lee
Hyeonjong Lee
DDDddd Dddd
Dddd Dddd
Taesung JeongTaesung Jeong
Taesung Jeong
Jonghyun ShinJonghyun Shin
Jonghyun Shin
Some resin polymers available for three-dimensional (3D) printing are slightly elastic, which may be advantageous when used for full crown coverage of the primary teeth. This study was performed to evaluate the mechanical properties of two types of 3D-printed resin crowns in terms of strength and surface characteristics. Polymer resins used for temporary crowns (TCs) and temporary flexible dentures (TFDs) were tested. Digitally designed crowns with different thicknesses (0.4 and 0.6 mm) were 3D-printed. Milled zirconia crowns were used as the control. The static and dynamic fracture loads of the crowns were measured. The crown surface was evaluated using scanning electron microscopy. The average strength did not differ between the types of crowns. The differences between the dynamic and static fracture loads were insignificant. In the TC group, thicker crowns showed lower strength both under static and dynamic loads. After thermomechanical loading, microcracks and dropouts of macrofillers were detected on the surface of all types of resin crowns. The deposition of abraded debris occurred more in the TFD group. The 3D-printed resin crowns were thought to endure biting forces in children. However, some limitations of the material itself should be improved for consideration as a new treatment option in pediatric dentistry.

23 November 2016 in Materials
Verified
Journal Article
Open access
PDF file
JPJin-Chul Park
Jin-Chul Park
EBEun-Bin Bae
Eun-Bin Bae
SKSe-Eun Kim
Se-Eun Kim
SKSo-Yun Kim
So-Yun Kim
KCKyung-Hee Choi
Kyung-Hee Choi
JHJung-Bo Huh
Jung-Bo Huh
This study was undertaken to investigate the effect of loading rhBMP-2 onto biphasic calcium phosphate (BCP) and calcium pyrophosphate (CPP) on bone regeneration, and to examine the efficacies of BCP and CPP as rhBMP-2 carriers. Specimens were divided into the BCP, CPP, BCP/BMP, and CPP/BMP groups; BCP and CPP were in granules and not coated with rhBMP-2. BCP/BMP and CPP/BMP were prepared as discs, which were treated with rhBMP-2 and collagen. Physical and biological features were investigated using in-vitro and in-vivo tests. New bone area percentages (%) in the BCP/BMP and CPP/BMP groups were significantly greater than in the BCP and CPP groups. At weeks 4 and 8 post-implantation, CPP/BMP showed the most new bone growth. Within the limitations of this study, treatment of BCP and CPP with rhBMP-2 significantly enhanced bone regeneration. CPP was found to be a suitable carrier for rhBMP-2.

Verified
Journal Article
Open access
PDF file
YSYoung-Gun Shin
Young-Gun Shin
WCWon-Tak Cho
Won-Tak Cho
HLHo-Kyung Lim
Ho-Kyung Lim
SHSu-hyun Hwang
Su-hyun Hwang
DDDddd Dddd
Dddd Dddd
JHJung-Bo Huh
Jung-Bo Huh
This prospective study was undertaken to evaluate the clinical usefulness of a newly developed one-piece, screw-free, and micro-locking implant system, which was designed to overcome the shortcomings of the existing implant systems. Thirty-eight patients were recruited and randomly and equally assigned to an experimental group (micro-locking one-piece fixture, MLF; n = 19) or a control group (micro-locking abutment, MLA). Cumulative implant survival rates, marginal bone resorptions, probing depths, plaque indices, bleeding indices, and complications were obtained by using clinical and radiographic findings at 6 months and 12 months after prosthesis placement. Complications that occurred multiple times for single implants were counted. During the 12 month observation period, survival rates were 100% in both groups. No significant intergroup differences were observed for marginal bone resorption, probe depth, or bleeding index. However, mean plaque index was significantly lower in the MLF group at 12 months (p < 0.05). During the 12-month observation period, food impaction (26.3%) was the main complication in the MLF group and screw loosening (5.3%), prosthesis detachment (5.3%), and food impaction (5.3%) were observed in the MLA group. The results of this study suggest that the one-piece micro-locking implant system offers a predictable treatment method.