Beti Rogina-Car

Dr. Beti Rogina-Car

University of Zagreb Faculty of Textile Technology, Department of Clothing Technology
orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 July 2020 in Polymers
Verified
Journal Article
Open access
PDF file
Beti Rogina-CarBeti Rogina-Car
Beti Rogina-Car
SKStana Kovačević
Stana Kovačević
Ivana SchwarzIvana Schwarz
Ivana Schwarz
KDKrste Dimitrovski
Krste Dimitrovski
The subject of the paper focuses on the effect of weave architecture on microbial barrier properties of woven fabrics or more precisely on identifying crucial elements of weave architecture that dominantly influence bacteria penetration in dry condition. For that purpose, 12 samples of cotton fabrics were woven and examined. In their structure, all samples had the same yarns (36 tex) in warp and weft, same densities of warp (24 yarns/cm), two weft densities (24 and 20 yarns/cm) and six different basic weave structures. Microbial barrier permeability was determined according to a previously developed test method in cooperation with University Hospital Center Zagreb. Bacterial endospores of apathogenic species of the genus Bacillus: Geobacillus stearothermophilus and Bacillus atrophaeus were used. The effect of weave pattern on microbial barrier properties was significant. Weave patterns, decisively determined the number of influencing pores and its sizes in woven fabrics, as well as the yarn floating which jointly almost perfectly correlated with bacteria penetration through the woven fabric. Multiple linear regression of pore numbers and floating threads produced equations which correspond in 99% to the measuring results for densities 24/24 and 24/20, and more than 98% considering both densities of the set. Among compared weave patterns, satin weave had significantly lower permeability of microorganisms (six–seven times) than basket weave (the highest), for both densities.

14 October 2018 in Journal of Industrial Textiles
Verified
Journal Article
Closed access
PDF file
Beti Rogina-CarBeti Rogina-Car
Beti Rogina-Car
JRJosip Rogina
Josip Rogina
EBEmi Govorčin Bajsić
Emi Govorčin Bajsić
ABAna Budimir
Ana Budimir
The aim of this study was to develop biodegradable medical nonwoven fabrics with added value, focusing on environmentally friendly natural substances for use in wound care. Propolis, a natural antibiotic, with confirmed antimicrobial and anti-inflammatory action was used. It was used in two formulations: ethanol extract of propolis and powder of native propolis. In order to obtain an environmentally friendly product, no chemical binder was used. Three modified procedures of applying propolis by immersing and scattering were used. Antimicrobial effect of the performed treatment was tested according to standard EN ISO 20645:2004 on three types of bacteria: Gram-positive Staphylococcus aureus (ATCC 6538), Gram-negative Escherichia coli (ATCC 11229) and Klebsiella pneumonia (ATCC4352). In this study, the microbial barrier properties of textiles for two bacterial endospores were investigated, with the aim of determining the microorganism mechanical permeability of textile. Fourier-transform infrared–attenuated total reflection was used to investigate the structural changes of Tencel nonwoven fabrics/propolis samples. On the basis of the results it can be concluded that the application of bee products, in this case of propolis in both formulations, on Tencel nonwoven fabrics provides satisfactory antimicrobial effects and an effective microbial barrier. Obtained results show that treatments 1 and 3 provide better antibacterial properties, indicating the further development potential of these treatments. AATCC Test Method 79, Absorbency of Textiles, was used to test absorption. The results show an increase in the absorption time of finished samples. The absorption time of finished samples can be reduced if they are stacked in a layered structure.

12 March 2020 in Polymers
Verified
Journal Article
Open access
PDF file
Beti Rogina-CarBeti Rogina-Car
Beti Rogina-Car
SKStana Kovačević
Stana Kovačević
SĐSuzana Đorđević
Suzana Đorđević
DDDragan Djordjevic
Dragan Djordjevic
The objective of this work was to determine the influence of washing and sterilization under real hospital conditions on properties of microbial barrier offered by polyurethane coated fabrics used in surgery and for wrapping sterile items. Emphasis was put on the change of surface polyurethane coating by using FTIR analysis. The permeability and durability of the microbial barrier were determined after 0, 10, and 20 washing and sterilization procedures according to previously developed methods. Bacterial endospores of the apathogenic species of the genus Bacillus Geobacillus stearothermophilus and Bacillus atrophaeus were used. Mechanical damage to medical textiles in the washing and sterilization process was determined according to standard HRN EN ISO 13914-1:2008 and associated with changes in physical and mechanical properties. Chemical changes of PU coatings were determined using FTIR analysis. The results showed an exceptionally efficient microbial barrier and its durability in all samples after 0, 10 and 20 washing and sterilization procedures and for a period of one, two and three months.

13 February 2014 in Cellulose
Verified
Journal Article
Closed access
PDF file
Beti Rogina-CarBeti Rogina-Car
Beti Rogina-Car
ABA. Budimir
A. Budimir
VTV. Turcic
V. Turcic
DKD. Katovic
D. Katovic

8 August 2016 in Textile Research Journal
Verified
Journal Article
Closed access
Beti Rogina-CarBeti Rogina-Car
Beti Rogina-Car
ABAna Budimir
Ana Budimir
DKDrago Katovic
Drago Katovic
In this study, the microbial barrier properties of textiles for two bacterial endospores were investigated. The reusable hospital textiles (PET/cotton and Tencel®) most commonly recommended for the manufacture of healthcare professional uniforms were tested for microorganism permeability. The three-layer textile laminate PET/PU/PET, which meets the European standards for surgical drapes EN 13795, was used as the reference material in this study. The microbial barrier properties of PET/cotton, Tencel®, PET/PU/PET, and corresponding seams were tested after 1, 10, 20, 30 and 50 washing-and-sterilization cycles. Washing and sterilization were performed by hospital laundry services under strict and controlled conditions. The testing of dry textile materials was conducted under newly developed methods. The most resistant forms of microorganisms of apathogenic bacterial endospores of the Bacillus genus Geobacillus stearothermophilus and Bacillus atrophaeus were used for investigating the microbial barrier permeability of textiles. This research is the first to investigate the permeability of these microorganisms in dry conditions. Additionally, the microbial barrier properties of the seams of these textiles were investigated. Regression analyses were performed and the effects of the seams on microorganism permeability were determined. It can be concluded that the two most commonly used seam types for the manufacture of healthcare uniforms do not have a significant influence on microbial barrier efficacy; however, the seam type 1.01.05/504.504.301 is more suitable for the manufacture of healthcare professional uniforms.

1 September 2018 in Autex Research Journal
Verified
Journal Article
Open access
PDF file
Beti Rogina-CarBeti Rogina-Car
Beti Rogina-Car
Ivana SchwarzIvana Schwarz
Ivana Schwarz
SKStana Kovačević
Stana Kovačević
Key importance and the role of sewn seam in the woven fabric are presented. Fabric properties in the places joined with the sewn seam on which garment durability, applicability, appearance and quality depend are highlighted. Seam location is usually the weakest spot on the garment, especially when the great loads are present at these places. Mechanical properties of the sewn fabrics were investigated in different test conditions. The influence of the load on the sewn seam is analyzed in time intervals. Sample with seam have approximately 70% lower breaking properties (breaking force and elongation at break) than the sample without seam. By preloading the seam fabrics with 30%, 50% and 70% of elongation at break, for a 3-h period, the effect on mechanical properties were tested and the differences in pre-stretching intensity were observed. By conducting such test, it is expected that the fabric experience further degradation and that breaking properties further reduce, but the exact opposite occurred (breaking properties, by increasing the preload, increase even more), because of various material properties (structural fabric properties, raw material characteristics, seam characteristics).