Next-generation communication systems are required to be efficient in power and spectrum usage. In this direction, novel spatial multiplexing techniques, such as orbital angular momentum (OAM), in contrast to frequency multiplexing, such as orthogonal frequency division multiplexing (OFDM), are regarded to uphold potential advantages. This letter investigates OAM and OFDM along with their emerging variants with index modulation (IM) in MIMO configuration. In this letter, these techniques are implemented for different cell distances mainly for single user cases. The bit error rate (BER) performance analysis is then carried out on a comparative scale. Moreover, Maximum likelihood and least square-based receiver techniques are presented for low complexity detection methods. The strengths and weaknesses of these techniques are analyzed through extensive MATLAB simulations for different Signal-to-Noise Ratios (SNRs).
The localization of agents for collaborative tasks is crucial to maintain the quality of the communication link for successful data transmission between the base station and agents. Power-domain Non-Orthogonal Multiple Access (P-NOMA) is an emerging multiplexing technique that enables the base station to accumulate signals for different agents using the same time-frequency channel. The environment information such as distance from the base station is required at the base station to calculate communication channel gains and allocate suitable signal power to each agent. The accurate estimate of the position for power allocation of P-NOMA in a dynamic environment is challenging due to the changing location of the end-agent and shadowing. In this paper, we take advantage of the two-way Visible Light Communication (VLC) link to (1) estimate the position of the end-agent in a real-time indoor environment based on the signal power received at the base station using machine learning algorithms and (2) allocate resources using the Simplified Gain Ratio Power Allocation (S-GRPA) scheme with the look-up table method. In addition, we use the Euclidean Distance Matrix (EDM) to estimate the location of the end-agent whose signal was lost due to shadowing. The simulation results show that the machine learning algorithm is able to provide an accuracy of 0.19 m and allocate power to the agent.
Due to the growing number of users, power, and spectral effectiveness, most communication systems are complex and difficult to implement on a large scale. Artificial Intelligence (AI) has played an outstanding role in the implementation of theoretical systems in the real world, with less complexity achieving better results. In this direction, we compare the Non-Orthogonal Multiple Access (NOMA) technique for a multiuser Visible Light Communication (VLC) system with Successive Interference Cancellation (SIC) for two types of detectors: (1) the deep learning-based system and (2) the traditional maximum likelihood (ML) decoder-based system. For multiplexing, we compare the variations of novel Orbital Angular Momentum (OAM) multiplexing and Orthogonal Frequency Division Multiplexing (OFDM) with Index Modulation (IM). In this article, we implement OFDM-IM and OAM-IM for four users for the Gaussian fading MIMO Line-of-Sight (LoS) and Non-Line-of-Sight (NLoS) VLC channels. The suggested systems’ bit error rate (BER) performances are compared in simulations for a wide range of Signal-to-Noise Ratios (SNRs), which shows that deep learning-based systems outperform the ML-based system for both users to ensure better decoding at the receiver end, especially at higher SNR values. The detection error is lower in a deep learning-based system at around 20% and around 30% for low SNR and high SNR values, respectively.
It is challenging in practice to achieve a steady-state value for external human recombinant erythropoietin (EPO) dosage to be administrated to maintain Hemoglobin (Hb) level within the desired range of 11-12 g/dl based on population-based models for anemia management due to inter-and intra-variability of the patients. On the other hand, Pharmacokinetic (PK) and Pharmacodynamic (PD) characteristics can vary for the patients over the course of treatment due to aging and other life changes. To address the inter-and intra-variability in anemia management, the semi-blind robust identification approach is proposed to obtain individualized patient models using limited number of clinical patient data. Semi-blind robust identification utilizes the effect of the initial condition during system identification to reduce the identification error. To reflect the patient's true dose-response relation as time passes and ensure the suitability of the individualized model for the controller, the model (In)validation technique is discussed to provide appropriate mathematical evidence about the suitability of the individualized model for dose prediction and controller design via testing it on new clinical data of the particular patient. One-step-ahead prediction results are shown for identified individualized patient models. The individualized patient models provide decision support to the clinicians about EPO dosage to avoid undershoot or overshoot of Hb level. Minimum mean squared error (MMSE) is calculated for the predicted values obtained by the models identified using semi-blind robust identification with and without the model (In)validation against clinically acquired EPO-Hb data.
10 January 2026 in Clinical Pharmacology & Therapeutics
Few studies have quantified the effects of non‐pharmacological interventions (e.g., rescue breathing) in the setting of community opioid overdose. We extended a previously validated model for opioid antagonists by incorporating the mechanism of rescue breathing, and quantified combinatorial effects between rescue breathing and various formulations of naloxone under different fentanyl overdose scenarios in a virtual patient population suffering from opioid‐induced respiratory failure. We defined successful reversal of an overdose as fewer than 5% of the virtual population experiencing cardiac arrest after intervention. Our model showed that timely rescue breathing reduced the naloxone dose needed for successful overdose reversal from greater than 8 mg (intranasal) to less than 2 mg (intramuscular) and extended the naloxone rescue window to 10 minutes under a median fentanyl intravenous overdose scenario. Administration of 4 mg naloxone intranasally reduced the duration of rescue breathing needed from 11 hours to 5 minutes under a median fentanyl transmucosal overdose scenario. High‐quality (as delivered by well‐trained rescuers), but not low‐quality (as delivered by laypersons), rescue breathing could successfully rescue severe opioid overdose scenarios. Even in cases where virtual subjects survived without naloxone, 4 mg intranasal naloxone provided benefit by shortening the time to recovery of spontaneous. Our results highlight the importance of utilizing both pharmacological and non‐pharmacological interventions in reversal of overdose.
1 January 2022 in IEEE Open Journal of Engineering in Medicine and Biology
Warfarin has been a challenging drug to administer due to the narrow therapeutic index of the International Normalized Ratio (INR), genetics, and effects of other medications. The fluctuation in INR leads to over– and under-anticoagulation. This becomes more strenuous due to the inter– and intra-variability of patients with a limited number of clinical data. Goal: To predict the optimal patient-specific warfarin dosage in the presence of the aforementioned challenges, we present an adaptive individualized modeling framework based on model (In)validation and semi-blind robust system identification method. The model (In)validation technique adapts the identified individualized patient model according to the change in the patient's status to ensure the model's suitability for prediction purposes and controller design. Results: To implement the proposed adaptive individualized patient modeling framework, the clinical data of warfarin-INR of forty-four patients has been collected at the Robley Rex Veterans Administration Medical Center, Louisville. The proposed adaptive model identification algorithm is compared with recursive ARX and ARMAX model identification methods. The results of identified models using one-step-ahead prediction and minimum mean squared analysis (MMSE) show that the proposed framework effectively predicts the warfarin dosage to keep the INR values within the desired range and adapt the individualized patient model to exhibit the true status of the patient throughout the course of treatment. Conclusion: This paper proposes an adaptive personalized patient modeling framework from limited patient-specific clinical data. It is shown by rigorous simulations that the proposed framework can accurately predict a patient's dose-response characteristics and it can alert the clinician whenever identified models are no longer suitable for prediction and adapt the model to the current status of the patient to reduce the prediction error.